EMC - CB Certificate
Brand
Device
Audio
File
cs460.pdf
Date

JBL CS460 EMC - CB Certificate ▷ View online

 
 
page 6 of 34 
Ref.No.:610599  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
8.6 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
 P 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Mains transformer 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
 N/A 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
This clause is not considered 
N/A 
 
Reinforced or double insulation between circuits 
operating at between 35 V and 71 V (peak) a.c. or 
between 60 V and 120 V d.c. and hazardous live 
parts at higher voltage 
 N/A 
 
Separation by Class 
ΙΙ isolating transformer 
 N/A 
 
Separation by Class 
Ι transformer 
 N/A 
 
Separation by earthed conductive part 
 
N/A 
8.8 
Basic or supplementary insulation 
≥ 0.4 mm (mm) : Prim. wires 
 
Reinforced insulation 
≥ 0.4 mm (mm) .................... : Transformer bobbins 
 Thin 
sheet 
insulation 
 
N/A 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 N/A 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 
 N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
 N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3 
 N/A 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
Applies to class I - appliances 
N/A 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
 N/A 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
Live wires are double 
insulated.  
No sec. wires can come into 
contact with live parts 
 
 
 
page 7 of 34 
Ref.No.:610599  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
8.11 
Detaching of wires 
 
No undue reduction of creepage or clearance 
distances if wires become detached 
No risk of any wire becoming 
detached 
N/A 
 
Vibration test carried out  ........................................ : No, no need. See above 
N/A 
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
 N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 P 
8.14 
Adequate fastening of covers (pull test 50 N, for 
10 s) 
 P 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
 P 
8.16 
Only special supply equipment can be used 
 
N/A 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
 
9.1.1 
Touch current measured from terminal devices 
using the network in Annex D  ................................ :
U1 = 0.08Vp (253V) 
U2 = 0.09Vp (253V) 
 
Discharge not exceeding 45 
μC 
 N/A 
 
Energy of discharge not exceeding 350 mJ 
 
N/A 
 
Test with test finger and test probe 
 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 P 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin 
 N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe 16 of IEC 61032 
 P 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1N); test probe D of IEC 61032 
 P 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
 N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
 P 
 
If C is not greater than 0.1 
μF no test needed 
 P 
 
 
page 8 of 34 
Ref.No.:610599  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
9.1.7 
Enclosure sufficiently resistant to external force 
 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 
 
Test hook of fig. 4 for 10 s (20 N) 
 
 
30 mm diameter test tool for 5 s (100 or 250 N)  ... :  
N/A 
9.2 
No hazard after removing a cover by hand 
 
N/A 
 
10 
INSULATION REQUIREMENTS  
 
 
(See appended table) 
 
10.1 
Insulation resistance (M
Ω) at least 2 MΩ min. after 
surge test for basic and 4 M
Ω min. for reinforced 
insulation 
>100M
Ω 
10.2 
Humidity treatment 48 h or 120 h 
Both 48 and 120h 
(see also page 32) 
10.3 
Insulation resistance and dielectric strength 
 
 
11 
FAULT CONDITIONS 
 
    (See 
appended 
table) 
 
11.1 
No shock hazard under fault conditions 
 
11.2 
Heating under fault condition 
 
 
No hazard from softening solder 
 
11.2.1 
Measurement of temperature rises 
 
11.2.2 
Temperature rise of accessible parts 
 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
 P 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of Table 2 by max. 100 K for 
max. 5 min 
 N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of Table 2 by not 
more than 100 K for an area not greater than 
2 cm
2
 
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm
2
 for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
198V: voltage interruption <50Vp. 
253V: no interruption, mains fuse 
broke (see table 11) 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
 P 
11.2.5 
Temperature rise of windings 
 
11.2.6 
Temperature rise of other parts not subject to the 
limits of 11.2.1 to 11.2.5 
 P 
 
 
page 9 of 34 
Ref.No.:610599  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
12 MECHANICAL 
STRENGTH 
 
12.1.1 Bump 
test 
 
12.1.2 
Vibration test 
No connection or part which 
might impair safety can 
become loose 
12.1.3 Impact 
test 
 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
12.3 
Remote controls with hazardous live parts 
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
 
N/A 
 
13 
CLEARANCES AND CREEPAGE DISTANCES 
 
13.1 
Clearances and creepage distances in accordance 
with 13.2 (fig. 9); minimum distance  ...................... :
Prim.-accessible metal parts: 
>10mm 
13.1.1 
Reduction applied if the 3 conditions are met  ....... :  
N/A 
 
Reduction applied for Grade 2 winding wire .......... :  
N/A 
13.1.2 
Use of cemented joints ........................................... :  
N/A 
 
Tests to confirm cemented joints 
 
N/A 
13.2 
Clearances and creepage distances of parts of 
different polarity connected to the mains, as in 
fig. 9; minimum distance  ........................................ :
>10mm P 
 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 N/A 
13.3 
Enclosed, enveloped or hermetically sealed parts: 
clearances and creepage distances to Table 4 
 N/A 
13.4 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
 N/A 
13.5 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 N/A 
 