JBL CS460 EMC - CB Certificate ▷ View online
page 30 of 34
Ref.No.:610599
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
NO: marking to state equipment must be
connected to an earthed mains socket-outlet
connected to an earthed mains socket-outlet
N/A
SE: marking required on equipment connected to
a telecommunication network, where separation
between the mains and the network relies on
connection to protective earth
a telecommunication network, where separation
between the mains and the network relies on
connection to protective earth
N/A
SE: marking to state equipment must be
connected to an earthed mains socket-outlet
connected to an earthed mains socket-outlet
N/A
B.8.1
DK: method b) of 8.1 is permitted only for
permanently connected equipment
permanently connected equipment
N/A
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N/A
B.14.12
DK: surge suppressors between
telecommunications network and accessible parts
permitted only for permanently connected
equipment
telecommunications network and accessible parts
permitted only for permanently connected
equipment
N/A
NO: surge suppressors between TNV circuits and
accessible parts of Class
accessible parts of Class
Ι equipment permitted
only if the equipment is marked stating it must be
connected to an earthed mains socket-outlet
connected to an earthed mains socket-outlet
N/A
SE: surge suppressors between TNV circuits and
accessible parts of Class
accessible parts of Class
Ι equipment permitted
only if the equipment is marked stating it must be
connected to an earthed mains socket-outlet, the
marking text is: "Apparaten skall anslutas till jordat
uttag"
connected to an earthed mains socket-outlet, the
marking text is: "Apparaten skall anslutas till jordat
uttag"
N/A
page 31 of 34
Ref.No.:610599
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS
5
DE: additional markings required in German language:
N/A
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
N/A
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N/A
5.1 IT:
additional
markings
on the outside of the TV
receiver in Italian language
N/A
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: certification number on the back cover
N/A
6.1 DE:
ionizing
radiation from TV receivers not
exceeding 1
μSv/h (= 7.2 pA/kg = 0.1 mR/h) at
10 cm
N/A
page 32 of 34
Ref.No.:610599
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
National differences SINGAPORE
IEC 60065, 6
th
edition
NOTE: (These differences are taken from IEC 60065:1993 and adopted to
IEC 60065:1998)
CB / SG 2006 I
Throughout the standard,
whenever the words "white pine board" appear, insert
the words "or plywood board" to it.
P
SS143 Amendment No. 1 and No. 2
4.1.3
(4.1.3)*
Delete "45 % to 75 %" and insert 65 ± 5 %.
75% maximum in IEC 60065:
1998
1998
P
7.1
(7.1)
Resistance to heat without external forces.
Adopt the temperature specified for the tropical
conditions.
conditions.
P
8.6
(9.3.4)
Delete the note " A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
This is not in IEC 60065:1998.
P
10.2
(10.2)
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
conditions.
120h at a relative humidity of
93%
93%
P
16
(16)
External flexible cords
Delete "IEC Publication 60227: Polyvinyl Chloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC publication 60245:
Rubber insulated Cables of rated up to and
including 450/750 V " and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC publication 60245:
Rubber insulated Cables of rated up to and
including 450/750 V " and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Delete "CEE Publication 13, CEE Publication 2
and IEC Publication 60173: Colours of the Cores
of Flexible Cables and Cords" whenever they
appear in this clause.
and IEC Publication 60173: Colours of the Cores
of Flexible Cables and Cords" whenever they
appear in this clause.
P
16.2
(16.2)
Delete the notes in small print and insert "A
nominal cross-sectional area of 0.75 mm² will
satisfy this requirement".
nominal cross-sectional area of 0.75 mm² will
satisfy this requirement".
This is not in IEC 60065:1998.
P
* in parenthesis: clauses acc. to IEC 60065:1993
page 33 of 34
Ref.No.:610599
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
16.3b
(16.4b)
Delete “Subclause 3.1 of IEC Publication 60227-2: Part
2: Test Methods“ and insert “Subclause 9.1 of SS 236“:
9.1 Flexing test (except for tinsel cords, twisted twin
and single core cords). The test shall be carried out by
means of the apparatus shown in Figure 5. This
apparatus has a carrier C supporting two pulleys A and
B arranged so that the cord is horizontal between the
pulleys. The carrier moves backward and forward over
a distance of 1 m at an approximately constant speed
of 0.33 m/s.
A sample of flexible cord about 5 m long shall be
stretched over the pulleys as shown in the figure, each
end being loaded with a weight. The weight and the
diameter of the pulleys A and B shall be given in Table
1.
Screened cords in accordance with Table 7 shall be
tested before application of the screen and outer
sheath.
tested before application of the screen and outer
sheath.
The pulleys shall have a semi-circular shaped groove
for circular cords and a flat groove for parallel twin
cords. The restraining clamps D shall be fixed so that
the pull is always applied by the weight from which the
carrier is moving away. The carrier shall make 30 000
backward and forward movements (60 000 single
strokes). Each conductor of the sample shall be loaded
with the current specified in Table 2.
for circular cords and a flat groove for parallel twin
cords. The restraining clamps D shall be fixed so that
the pull is always applied by the weight from which the
carrier is moving away. The carrier shall make 30 000
backward and forward movements (60 000 single
strokes). Each conductor of the sample shall be loaded
with the current specified in Table 2.
For twin cords and for light PVC-sheated 3-core cords,
the voltage between the conductors shall be
approximately 230 V a.c. For all other cords having
three or more cores a three-phase a.c. voltage of about
400 V shall be applied to three conductors, any
additional conductors being connected to the neutral.
the voltage between the conductors shall be
approximately 230 V a.c. For all other cords having
three or more cores a three-phase a.c. voltage of about
400 V shall be applied to three conductors, any
additional conductors being connected to the neutral.
During the test no open-circuit in any core or short-
circuit between cores shall occur.
circuit between cores shall occur.
After the test, any sheath on cords having three or
more cores shall be removed. The cord, or the laid up
cores, shall then withstand the voltage test specified in
Subclause 8.2 or 8.3 as appropriate, but with a test
voltage not exceeding 2000 V.
TABLE 1, TABLE 2, FIGURES 4 and 5, see the
CB BULLETIN
P