JBL CS460 EMC - CB Certificate ▷ View online
page 14 of 34
Ref.No.:610599
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
P
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N/A
15.1.3
Output terminals of AC adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class
Ι equipment
reliably connected to earth terminal, within
equipment
equipment
N/A
Class
Ι supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
earth
N/A
Protective earth conductors correctly coloured
N/A
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
N/A
Earth resistance (
Ω) ≤ 0.1 Ω at 25 A ..................... : N/A
15.3
Terminals for external flexible cords and for permanent connection to the mains supply
15.3.1
Adequate terminals for connection of permanent
wiring
wiring
N/A
15.3.2
Reliable connection of non-detachable cords:
not soldered to conductors of a printed circuit
board
board
N/A
adequate clearances and creepage distances
between connections should a wire break away
between connections should a wire break away
N/A
wire secured by additional means to the conductor
N/A
15.3.3
Screws and nuts clamping conductors have
adequate threads: ISO 261, ISO 262 or similar
adequate threads: ISO 261, ISO 262 or similar
N/A
15.3.4
Soldered conductors wrapped around terminal
prior to soldering or held in place by additional
means
prior to soldering or held in place by additional
means
N/A
Clamping of conductor and insulation if not
soldered or held by screws
soldered or held by screws
N/A
page 15 of 34
Ref.No.:610599
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
15.3.5
Terminals allow connection of appropriate cross-
sectional area of conductors, for the rated current
of the equipment
sectional area of conductors, for the rated current
of the equipment
N/A
15.3.6
Terminals to 15.3.3 have sizes required by Table 8
N/A
15.3.7
Terminals clamp conductors between metal and
have adequate pressure
have adequate pressure
N/A
Terminals designed to avoid conductor slipping out
when tightened or loosened
when tightened or loosened
N/A
Terminals adequately fixed to avoid loosening
when the clamping is tightened or loosened and
stress on internal wiring is avoided
when the clamping is tightened or loosened and
stress on internal wiring is avoided
N/A
15.3.8
Terminals carrying a current more than 0.2 A:
contact pressure not transmitted by insulating
material except ceramic
contact pressure not transmitted by insulating
material except ceramic
N/A
15.3.9
Termination of non-detachable cords: wires
terminated near to each other
terminated near to each other
N/A
Terminals located and shielded: test with 8 mm
strand
strand
N/A
15.4
Devices forming a part of the mains plug
15.4.1
No undue strain on mains socket-outlets
N/A
15.4.2
Device complies with standard for dimensions of
mains plugs
mains plugs
N/A
15.4.3
Device has adequate mechanical strength (tests
a,b,c)
a,b,c)
N/A
page 16 of 34
Ref.No.:610599
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
16
EXTERNAL FLEXIBLE CORDS
16.1
Mains cords sheathed type, complying with
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
IEC 60227 for PVC or IEC 60245 for synthetic
rubber cords ............................................................ :
PVC
P
Non-detachable cords for Class
Ι have
green/yellow core for protective earth
N/A
16.2
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the
equipment
sectional area for rated current consumption of the
equipment
2x0.75mm
2
P
16.3
a) Flexible cords not complying with 16.1, used for
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
interconnections between separate units of
equipment used in combination and carrying
hazardous live voltages, have adequate dielectric
strength
N/A
b) Flexible cords not complying with 16.1,
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
withstand bending and mechanical stress (3.2 of
IEC 60227-2)
N/A
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N/A
16.5
Adequate strain relief on external flexible cords
N/A
Not possible to push cord back into equipment
N/A
Strain relief device unlikely to damage flexible cord
N/A
For mains cords of Class
Ι equipment, hazardous
live conductors become taut before earth
conductor
conductor
N/A
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
N/A
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
N/A
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N/A
page 17 of 34
Ref.No.:610599
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to Table 12:
- screws into metal: 5 times
N/A
- screws into non-metallic material: 10 times
P
17.2
Correct introduction into female threads in non-
metallic material
metallic material
P
17.3
Cover fixing screws: captive
N/A
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
P
17.4
No loosening of conductive parts carrying a current
> 0.2 A
> 0.2 A
N/A
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0.2 A
other than ceramic for connections carrying a
current > 0.2 A
N/A
17.6
Stranded conductors of flexible supply cords
carrying a current > 0.2 A with screw terminals not
consolidated by solder
carrying a current > 0.2 A with screw terminals not
consolidated by solder
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
N/A
17.8
Fixing devices for detachable legs or stands
provided
provided
N/A
17.9
P
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST
THE EFFECTS OF IMPLOSION
THE EFFECTS OF IMPLOSION
18.1
Picture tube separately approved .......................... :
N/A
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically
protected tubes > 16 cm used
with protective screen
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
Click on the first or last page to see other CS460 service manuals if exist.