JBL CS460 EMC - CB Certificate ▷ View online

 
 
page 2 of 34 
Ref.No.:610599 
 
TRF No.: I60065__C 
 
Test item
 
Description ......................................... : Powered Subwoofer 
Trademark.......................................... : 
 
Model and/or type reference.............. :  CS60SUB/230 
Manufacturer ...................................... :  Harman Consumer Group 
Rating(s)............................................. :  AC 220-230V , 50-60Hz, 220W, Class 
ΙΙ 
Test case verdicts
 
Test case does not apply to the test object.................. : N/A (Not Applicable) 
Test item does meet the requirement .......................... : P (Pass) 
Test item does not meet the requirement .................... : F (Fail) 
Testing
 
Date of receipt of test item ........................................... : 21 August 2006 
Date(s) of performance of test...................................... : 14- 16 October 2006 
General remarks
 
 
“This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a NCB, in 
accordance with IECEE 02”. 
 
This test report shall not be reproduced except in full without the written approval of the testing laboratory. 
 
The test results presented in this report relate only to the item tested. 
 
“(see remark #)” refers to a remark appended to the report. 
 
“(see appended table)” refers to a table appended to the report. 
 
Throughout this report a point is used as the decimal separator. 
 
 
 
 
 
 
 
 
page 3 of 34 
Ref.No.:610599 
 
TRF No.: I60065__C 
 
Copy of marking plate 
 
 
 
 
Note: This test report is based on test reports with ref. Nos. 310127 and 520073 for JBL model 
SUB200/230. New heating tests at P1/8 and P100% has been performed. 
  
Excerpt from OM concerning LFE-input: 
 
 
 
 
 
 
 
 
 
 
page 4 of 34 
Ref.No.:610599  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
3 GENERAL 
REQUIREMENTS 
 
 
Safety class of the apparatus ................................. : Class II 
 
GENERAL CONDITIONS OF TESTS 
 
4.1.4 
Ventilation instructions require the use of the test 
box 
No N/A 
 
5 MARKING 
 
 
Comprehensible and easily discernible 
 
 
Permanent durability against water and petroleum 
spirit 
 P 
5.1 Identification, 
maker, model ................................... :
 CS60SUB/230 
 
Class 
ΙΙ symbol 
 
 
Rated supply voltage and symbol .......................... : AC 220-230V, 50-60Hz 
 
Rated current or power consumption  .................... : (220W) N/A 
5.2 Earth 
terminal 
 
N/A 
 
Hazardous live terminals 
 
N/A 
 
Supply output terminals (other than mains) 
 
N/A 
5.3 
Use of triangle with exclamation mark 
 
N/A 
5.4 
Instructions for use 
5.4.1 
Mains powered equipment not exposed to dripping 
or splashing 
 P 
 
Hazardous live terminals, instructions for wiring 
 
N/A 
 
Instructions for replacing lithium battery 
 
N/A 
 
Explanation of marking of the manually operated 
mechanical switch (MOMS) 
 N/A 
5.4.2 
Instructions for permanently connected equipment   
N/A 
 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation 
≤ 36 pA/kg (0.5 mR/h) 
 N/A 
6.2 
Laser radiation, emission limits to IEC 60825  ....... :   
N/A 
 
Emission limits under fault conditions 
  
N/A 
 
 
 
page 5 of 34 
Ref.No.:610599  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
HEATING UNDER NORMAL OPERATING CONDITIONS 
(See appended table) 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0.2 A at least 150 ºC 
 N/A 
 
8 CONSTRUCTIONAL 
REQUIREMENTS 
WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
 P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
 N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
Not used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
  
8.5 
Class 
Ι equipment 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1a 
 N/A 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
 
Class 
ΙΙ equipment and Class ΙΙ constructions 
within Class 
Ι equipment 
 N/A 
Page of 46