JBL CINEMA 610 EMC - CB Certificate ▷ View online
Page 4 of 99
Report No.: 17032770 001
TRF No. IEC60065K
Summary of compliance with National Differences
List of countries addressed:
EU Group Differences, EU Special National Conditions, EU A-Deviations, AT, AU, BE, CA*, CH, CN*, CZ,
DE, DK, FI, FR, GB, GR, HU, IT, JP*, KR, MY*, NL, NO, PL, SE, SI, SK, US*.
DE, DK, FI, FR, GB, GR, HU, IT, JP*, KR, MY*, NL, NO, PL, SE, SI, SK, US*.
AT=Austria, AU=Australia, BE=Belgium, CA=Canada, CH=Switzerland, CN=China, CZ=Czech Republic,
DE=Germany, DK=Denmark, FI=Finland, FR=France, GB=United Kingdom, GR=Greece, HU=Hungary,
IT=Italy, JP=Japan, KR=Korea, MY=Malaysia, NL=The Netherlands, NO=Norway, PL=Poland,
SE=Sweden, SI=Slovenia, SK=Slovakia, US=United States of America.
DE=Germany, DK=Denmark, FI=Finland, FR=France, GB=United Kingdom, GR=Greece, HU=Hungary,
IT=Italy, JP=Japan, KR=Korea, MY=Malaysia, NL=The Netherlands, NO=Norway, PL=Poland,
SE=Sweden, SI=Slovenia, SK=Slovakia, US=United States of America.
*For these countries accepting IEC 60065: 2001 + A1 only.
For National Differences see end of this test report.
Copy of marking plate
The use of certification marks on a product must be authorized by the respective NCBs that own these
marks.
marks.
Remark:
‘YY-MM-DD’ on above label denotes manufacture date.
Page 5 of 99
Report No.: 17032770 001
TRF No. IEC60065K
Test item particulars .............................................. :
Classification of installation and use .................... : Class II
Supply Connection ................................................ : Appliance inlet used
............................................................................... :
Possible test case verdicts:
- test case does not apply to the test object ..........: N/A (Not Applicable)
- test object does meet the requirement.................: P (Pass)
- test object does not meet the requirement ..........: F (Fail)
Testing:
Date of receipt of test item .....................................: May 09, 2013
Date (s) of performance of tests .............................: May 23
– May 28, 2013
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.
Throughout this report a
comma /
point is used as the decimal separator.
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided .................................................. :
includes more than one factory location and a
declaration from the Manufacturer stating that the
sample(s) submitted for evaluation is (are)
representative of the products from each factory
has been provided .................................................. :
Yes
Not applicable
Name and address of factory (ies) ........................ : Evervictory Electronic Co., Ltd.
Chu-chi Management District, Hu-men Town,
Dongguan, Guangdong, P.R. China
Dongguan, Guangdong, P.R. China
General product information:
The EUT covered by this report is a Home Theater Subwoofer, which is connected to the output of Low-
Frequency Effects (LFE) channel on receiver or amplifier and is powered by AC mains.
Frequency Effects (LFE) channel on receiver or amplifier and is powered by AC mains.
The product mainly consists of:
1.
Built-in power board.
2.
Enclosure (metal, wooden, plastic)
3.
Speaker
Mass of main unit: approx. 8 kg.
Page 6 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
3
General requirements
P
Safety class of the apparatus ................................: Class II
P
4
General test conditions
P
4.1.4
Ventilation instructions require the use of the test
box
box
Yes
P
5
Marking and instructions
P
Comprehensible and easily discernible
Located on rear enclosure.
P
Permanent durability against water and petroleum
spirit
spirit
The marking is legible and
label show not any curling after
test
label show not any curling after
test
P
5.1
a) Identification, maker ........................................ : See copy of marking plate on
page 4.
P
b) Model number or type reference ....................... : See copy of marking plate on
page 4.
P
c) Class II symbol if applicable ............................. : See copy of marking plate on
page 4.
P
d) Nature of supply ............................................... : ~
P
e) Rated supply voltage ....................................... : 100-240V
P
f) Mains frequency if safety dependant ................. : 50/60Hz
P
g) Rated current or power consumption for
apparatus supplied by supply apparatus for general
use ..................................................................... :
apparatus supplied by supply apparatus for general
use ..................................................................... :
N/A
Measured current or power consumption ............. :
N/A
Deviation % (max 10%) ....................................... :
N/A
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply :
us intended for connection to an a.c. mains supply :
See copy of marking plate on
page 4.
page 4.
P
Measured current or power consumption ............. : (see appended table 7.1)
P
Measured current or power consumption for
Television set ...................................................... :
Television set ...................................................... :
N/A
Deviation % (max 10%) ....................................... : (see appended table 7.1)
P
5.2
a) Earth terminal
Class II apparatus
N/A
b) Hazardous live terminals
N/A
c) Markings on supply output terminals
N/A
5.3
a) Use of triangle with exclamation mark
Marked on the circuit diagram
P
b) marking on loudspeaker grille, IEC 60417-5036
N/A
5.4
Instructions for use
In English
P
Page 7 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
5.4.1
a) Mains powered equipment not exposed to
dripping or splashing. Warning concerning objects
filled with liquid, etc.
dripping or splashing. Warning concerning objects
filled with liquid, etc.
Stated in the instruction
P
b) Hazardous live terminals, instructions for wiring
No such terminals.
N/A
c) Instructions for replacing lithium battery
No battery used.
N/A
d) Class I earth connection warning
Class II apparatus
N/A
e) Instructions for multimedia system connection
P
f) Special stability warning for attachment of the
apparatus to the floor/wall
apparatus to the floor/wall
No such installation.
N/A
g) Warning: battery exposure to heat
No battery used.
N/A
h) Warning: protective film on CRT face
No CRT used.
N/A
5.4.2
a-b) Disconnect device: plug/coupler or all-pole
mains switch location, accessibility and markings
mains switch location, accessibility and markings
Stated in the instruction
regarding the power plug shall
be readily operable.
regarding the power plug shall
be readily operable.
P
c) Instructions for permanently connected equipment Not permanently connected
equipment.
N/A
Marking, signal lamps or similar for completely
disconnection from the mains
disconnection from the mains
N/A
6
Hazardous radiation
N/A
6.1
Ionizing radiation < 36 pA/kg (0,5 mR/h)
No such device
N/A
Ionizing radiation under fault condition
N/A
6.2
Laser radiation, emission limits to IEC 60825-1:2007
............................................................................:
............................................................................:
No laser produced.
N/A
Emission limits under fault conditions ....................:
N/A
7
Heating under normal operating conditions
P
7.1
Temperature rises not exceeding specified values;
fuse links and other protective devices defeated
fuse links and other protective devices defeated
(see appended table 7.1)
P
7.1.1
Temperature rise of accessible parts
(see appended table 7.1)
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
(see appended table 7.1)
P
7.1.3
Temperature rise of parts acting as a support or as a
mechanical barrier
mechanical barrier
(see appended table 7.1)
P
7.1.4
Temperature rise of windings
(see appended table 7.1)
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
(see appended table 7.1)
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
supporting parts conductively connected to the
mains carrying a current > 0,2 A at least 150
o
C
(see appended table 7.2)
P
Click on the first or last page to see other CINEMA 610 service manuals if exist.