DOWNLOAD JBL CINEMA 610 Service Manual ↓ Size: 1.79 MB | Pages: 108 in PDF or view online for FREE

Model
CINEMA 610
Pages
108
Size
1.79 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
cinema-610.pdf
Date

JBL CINEMA 610 EMC - CB Certificate ▷ View online

 
 
 
 
Page 4 of 99 
 
 
 
Report No.: 17032770 001 
 
 
TRF No. IEC60065K 
Summary of compliance with National Differences 
List of countries addressed: 
EU Group Differences, EU Special National Conditions, EU A-Deviations, AT, AU, BE, CA*, CH, CN*, CZ, 
DE, DK, FI, FR, GB, GR, HU, IT, JP*, KR, MY*, NL, NO, PL, SE, SI, SK, US*. 
AT=Austria, AU=Australia, BE=Belgium, CA=Canada, CH=Switzerland, CN=China, CZ=Czech Republic, 
DE=Germany, DK=Denmark, FI=Finland, FR=France, GB=United Kingdom, GR=Greece, HU=Hungary, 
IT=Italy, JP=Japan, KR=Korea, MY=Malaysia, NL=The Netherlands, NO=Norway, PL=Poland, 
SE=Sweden, SI=Slovenia, SK=Slovakia, US=United States of America. 
 
*For these countries accepting IEC 60065: 2001 + A1 only. 
For National Differences see end of this test report. 
 
Copy of marking plate 
The use of certification marks on a product must be authorized by the respective NCBs that own these 
marks. 
    
 
 
Remark:  
‘YY-MM-DD’ on above label denotes manufacture date. 
 
 
 
 
 
Page 5 of 99 
 
 
 
Report No.: 17032770 001 
 
 
TRF No. IEC60065K 
 
Test item particulars .............................................. :   
Classification of installation and use .................... :  Class II 
Supply Connection ................................................ :  Appliance inlet used 
 ............................................................................... :   
Possible test case verdicts: 
 
- test case does not apply to the test object ..........:  N/A (Not Applicable) 
- test object does meet the requirement.................:  P (Pass) 
- test object does not meet the requirement ..........:  F (Fail) 
Testing: 
 
Date of receipt of test item .....................................:  May  09, 2013 
Date (s) of performance of tests .............................:  May 23 
– May 28, 2013 
 
 
General remarks: 
The test results presented in this report relate only to the object tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
"(see Enclosure #)" refers to additional information appended to the report. 
"(see appended table)" refers to a table appended to the report. 
 
Throughout this report a 
 comma / 
 point is used as the decimal separator. 
 
Manufacturer’s Declaration per sub-clause 6.2.5 of IECEE 02: 
The application for obtaining a CB Test Certificate 
includes more than one factory location and a 
declaration from the Manufacturer stating that the 
sample(s) submitted for evaluation is (are) 
representative of the products from each factory 
has been provided .................................................. : 
 Yes 
Not applicable 
Name and address of factory (ies) ........................ :  Evervictory Electronic Co., Ltd. 
Chu-chi Management District, Hu-men Town,  
Dongguan, Guangdong, P.R. China 
 
General product information: 
The EUT covered by this report is a Home Theater Subwoofer, which is connected to the output of Low-
Frequency Effects (LFE) channel on receiver or amplifier and is powered by AC mains.  
 
The product mainly consists of: 
1. 
Built-in power board. 
2. 
Enclosure (metal, wooden, plastic) 
3. 
Speaker 
 
Mass of main unit: approx. 8 kg. 
 
 
 
 
 
 
Page 6 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
General requirements 
 
Safety class of the apparatus  ................................:  Class II 
 
4 
General test conditions 
4.1.4 
Ventilation instructions require the use of the test 
box  
Yes 
 
5 
Marking and instructions 
 
Comprehensible and easily discernible 
Located on rear enclosure. 
 
Permanent durability against water and petroleum 
spirit  
The marking is legible and 
label show not any curling after 
test 
5.1 
a) Identification, maker  ........................................ :  See copy of marking plate on 
page 4. 
 
b) Model number or type reference ....................... :  See copy of marking plate on 
page 4. 
 
c) Class II symbol if applicable  ............................. :  See copy of marking plate on 
page 4. 
 
d) Nature of supply ............................................... :  ~ 
 
e) Rated supply voltage  ....................................... :  100-240V 
 
f) Mains frequency if safety dependant  ................. :  50/60Hz 
 
g) Rated current or power consumption for 
apparatus supplied by supply apparatus for general 
use  ..................................................................... : 
 
N/A 
 
Measured current or power consumption  ............. :   
N/A 
 
Deviation % (max 10%)  ....................................... :   
N/A 
 
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply  : 
See copy of marking plate on 
page 4. 
 
Measured current or power consumption  ............. :  (see appended table 7.1) 
 
Measured current or power consumption for 
Television set  ...................................................... : 
 
N/A 
 
Deviation % (max 10%)  ....................................... :  (see appended table 7.1) 
5.2 
a) Earth terminal  
Class II apparatus 
N/A 
 
b) Hazardous live terminals  
 
N/A 
 
c) Markings on supply output terminals 
 
N/A 
5.3 
a) Use of triangle with exclamation mark  
Marked on the circuit diagram  
 
b) marking on loudspeaker grille, IEC 60417-5036 
 
N/A 
5.4 
Instructions for use 
In English 
 
 
 
 
Page 7 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
Stated in the instruction 
 
b) Hazardous live terminals, instructions for wiring   
No such terminals. 
N/A 
 
c) Instructions for replacing lithium battery  
No battery used. 
N/A 
 
d) Class I earth connection warning  
Class II apparatus 
N/A 
 
e) Instructions for multimedia system connection  
 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
No such installation. 
N/A 
 
g) Warning: battery exposure to heat  
No battery used. 
N/A 
 
h) Warning: protective film on CRT face  
No CRT used. 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
Stated in the instruction 
regarding the power plug shall 
be readily operable. 
 
c) Instructions for permanently connected equipment   Not permanently connected 
equipment. 
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 
N/A 
 
Hazardous radiation 
N/A 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
No such device 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1:2007
 ............................................................................: 
No laser produced. 
N/A 
 
Emission limits under fault conditions  ....................:   
N/A 
 
7 
Heating under normal operating conditions 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts  
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table 7.1) 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table 7.1) 
7.1.4 
Temperature rise of windings  
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table 7.1) 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
(see appended table 7.2) 
 
Page of 108
Display