JBL CINEMA 610 EMC - CB Certificate ▷ View online
Page 20 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
17.2
Correct introduction into female threads in non-
metallic material
metallic material
P
17.3
Cover fixing screws: captive
N/A
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter
by a screw whose length is 10 times its diameter
P
17.4
No loosening of conductive parts carrying a current
> 0,2 A
> 0,2 A
P
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a current
> 0,2 A
other than ceramic for connections carrying a current
> 0,2 A
P
17.6
Stranded conductors of flexible supply cords
carrying a current > 0,2 A with screw terminals not
consolidated by solder
carrying a current > 0,2 A with screw terminals not
consolidated by solder
No such cords used.
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
N/A
17.8
Fixing devices for detachable legs or stands
provided
N/A
17.9
N/A
18
Mechanical strength of picture tubes and protection against the effects of
implosion
implosion
N/A
18.1
Picture tube separately approved to IEC 61965 ....:
Yes / No
N/A
Picture tube separately approved to 18.2 .............:
Yes / No
N/A
18.2
Non-intrinsically protected tubes tested to 18.2
N/A
19
Stability and mechanical hazards
P
Mass of the equipment exceeding 7 kg ................:
> 7kg
P
Apparatus intended to be fastened in place
–
suitable instructions .............................................:
Not fastened in place.
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
P
19.2
100 N force applied vertically downwards
P
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability
to point of least stability
The test does not apply.
N/A
19.4
Edges or corners not hazardous
The edges and corners are
smoothed.
smoothed.
P
19.5
Glass surfaces (exc.laminated) with an area
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
exceeding 0,1 m² or maximum dimension
> 450 mm, pass the test of 19.5.1
No glass surfaces.
N/A
19.6
Wall or ceiling mountings adequate
No mounting means.
N/A
Page 21 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
20
Resistance to fire
P
20.1
Electrical components and mechanical parts
P
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1
20.1
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
Clause 14 or 20.1.4
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
> 4 kV or leaving an internal fire enclosure, or
located within the areas mentioned in Table 21, not
contributing to the spread of fire
No working voltages > 4 kV
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
PCB with flammability category
V-0 used.
V-0 used.
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
PCB with flammability category
V-0 used.
V-0 used.
P
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
(see appended table)
Foam on secondary wires is
V-1 or better.
V-1 or better.
Wooden enclosure with
thickness 9.0mm considered
as V-1 fire enclosure.
thickness 9.0mm considered
as V-1 fire enclosure.
Distance between PIS and HB
enclosure more than 60mm.
enclosure more than 60mm.
P
Components and parts as above but shielded from a
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Apparatus with voltages >4kV under normal
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
operating conditions and distances to the enclosure
exceed those specified Table 21, flammability
classification HB40 or better is required for the
enclosure
N/A
20.2
Fire enclosure
N/A
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N/A
20.2.2
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
internal fire enclosure
N/A
Page 22 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
N/A
A.5
Marking and instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
N/A
A.10
Insulation requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
NETWORKS
N/A
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
N/A
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.7
Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
N/A
Page 23 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
L. 9
Electric shock hazard under normal operating
conditions
conditions
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10
Insulation requirements
N/A
L. 10.3.2
High frequency puls ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c)
Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
to be a POTENTIAL IGNITION SOURCE
N/A