Page 8 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
Constructional requirements with regard to the protection against electric 
shock 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
No such material 
N/A 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
No voltage setting device, 
replaceable fuse-links or 
drawers. 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
 
8.5 
Class I equipment  
Class II apparatus 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
Transformers T1 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
Y Capacitors (CY1, CY2 and 
CY4) used between primary 
and secondary circuit. 
8.7 
This clause is void  
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
Thickness of transformer 
bobbin: 0.5mm 
 
Reinforced insulation > 0,4 mm (mm)  .................. : 
See appended table 14 for 
below information: 
thickness of enclosure  
optocoupler 
 
 
 
 
Page 9 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
3 layers insulation tape 
between primary winding and 
secondary winding, also see 
table 10.3. 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
Double/reinforced insulation 
between primary live parts and 
accessible parts 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
Basic insulated secondary 
wires can not touch hazardous 
live parts 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
 
 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts. 
 
8.11 
Detaching of wires  
 
 
No undue reduction of creepages or clearance 
distances if wires become detached  
Primary wires connected to 
power board by connector. 
Wires connected to power 
board by connector and 
amplifier board by soldering 
after inserting into holes of 
PCB with adhesive 
additionally. 
 
Vibration test carried out  ..................................... : 
Yes 
8.12 
This clause is void  
 
 
8.13 
Adequate fastening of windows, lenses, lamp covers 
etc. (pull test 20 N for 10 s)  
 
8.14 
Adequate fastening of covers (push/pull test 50 N for 
10 s)  
No such covers.  
N/A 
8.15 
No risk of damage to the insulation of internal wiring 
due to hot parts or sharp edges  
8.16 
Only special supply equipment can be used  
 
N/A 
8.17 
Insulated winding wire without additional interleaved 
insulation  
No such wires used. 
N/A 
8.18 
Endurance test as required by 8.17  
 
N/A 
 
 
 
 
Page 10 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
8.19 
Disconnection from the mains 
Mains plug/coupler used 
8.19.1 
Disconnect device  
 
 
All-pole switch or circuit breaker with >3mm contact 
separation  
 
N/A 
8.19.2 
Mains switch ON indication  
No such mains switch 
N/A 
8.20 
Switch not fitted in the mains cord  
Not fitted in the mains cord. 
8.21 
Bridging components comply with clause 14  
 
N/A 
8.22 
Non-separable thin sheet material  
 
N/A 
 
Electric shock hazard under normal operating conditions 
9.1 
Testing on the outside 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
< 1000 V 
N/A 
9.1.1.1 
a) Open circuit voltages  
See appended table for max. 
output of SPS. 
 
b) Touch current measured from terminal devices 
using the network in annex D ...............................: 
(see appended table 9.1.1) 
 
c) Discharge not exceeding 45 
μC  
< 45 
μC 
 
d) Energy of discharge not exceeding 350 mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
 
9.1.2 
No hazardous live shafts of knobs, handles or levers    
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  .................: 
Max. 28Vpeak measured after 
2 s (limit: 35Vpeak) 
 
If C is not greater than 0,1 
μF no test needed  
 
N/A 
9.1.7 
Resistance to external forces 
 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
 
N/A 
 
b) Test hook of fig. 4 for 10 s (20 N)  
 
N/A 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
100N 
9.2 
No hazard after removing a cover by hand  
No such removable cover. 
N/A 
 
10 
Insulation requirements 
 
 
 
 
Page 11 of 99 
 
 
 
Report No.: 17032770 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 
MΩ min. for reinforced 
insulation  ............................................................: 
No antenna connection. 
N/A 
10.2 
Humidity treatment 48 h or 120 h  .........................: 
95% R. H., 40
o
C, 120h  
(manufacturer requirement) 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
(see appended table) 
 
Insulation Resistance and dielectric strength across 
BASIC or SUPPLEMENTARY insulation (Class I)  
 
N/A 
 
Insulation resistance and dielectric strength across 
REINFORCED insulation (Class II)  
 
 
11 
Fault conditions 
11.1 
No shock hazard under fault condition  
(see appended table 11.1) 
11.2 
Heating under fault condition  
 
 
Flames extinguish within 10 seconds  
No flames 
N/A 
 
No hazard from softening solder  
No softening solder 
N/A 
 
Soldered terminations not used  as protective 
mechanism  
 
11.2.1 
Measurement of temperature rises  
(see appended table) 
11.2.2 
Temperature rise of accessible parts  
(see appended table) 
11.2.3 
Temperature rise of parts, other than windings and 
printed boards, providing electrical insulation 
(see appended table) 
11.2.4 
Temperature rise of parts acting as a support or  
mechanical barrier  
 
11.2.5 
Temperature rise of windings  
(see appended table) 
11.2.6 
Temperature rise of printed boards shall not exceed 
the limits of table 3 by max. 100 K for max. 5 min 
(see appended table) 
 
Printed circuit boards (PCB) classified as V-0 
according to 60695-11-10 or Clause G.1 may 
exceed the limit in table 3 in case a) and b): 
 
N/A 
 
a) Temperature rise of printed circuit boards 
exceeding the limits of table 3 by not more than 
100 K for an area not greater than 2 cm²  ............... : 
 
N/A 
 
b) Temperature rise of printed circuit boards 
exceeding the limits of table 3 up to 300 K for an 
area not greater than 2 cm² for a maximum of 5 min  
 
N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted  
 
N/A 
 
Class I protective earthing maintained  
 
N/A 
Page of 108