JBL CINEMA 610 EMC - CB Certificate ▷ View online
Page 8 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8
Constructional requirements with regard to the protection against electric
shock
shock
P
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
No such material
N/A
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
No voltage setting device,
replaceable fuse-links or
drawers.
replaceable fuse-links or
drawers.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
P
8.4
No risk of electric shock from accessible parts or
from parts rendered accessible following the
removal of a cover which can be removed by hand
from parts rendered accessible following the
removal of a cover which can be removed by hand
P
8.5
Class I equipment
Class II apparatus
N/A
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Resistors bridging basic insulation complying with
14.1 a)
14.1 a)
N/A
Capacitors bridging basic insulation complying with
14.2.1 a)
14.2.1 a)
N/A
Protective earthing terminal
N/A
8.6
Class II equipment and Class II constructions within
Class I equipment
Class I equipment
P
Double or reinforced insulation between hazardous
live parts and accessible parts
live parts and accessible parts
P
Components bridging double or reinforced insulation
complying with 14.1 a) or 14.3
complying with 14.1 a) or 14.3
Transformers T1
P
Basic insulation bridged by components complying
with 14.3.4.3.
with 14.3.4.3.
N/A
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.1 a)
bridged by a capacitor complying with 14.1 a)
N/A
Double or reinforced insulation being bridged with 2
capacitors in series complying with 14.2.1 a)
capacitors in series complying with 14.2.1 a)
N/A
Double or reinforced insulation being bridged with a
single capacitor complying with 14.2.1 b)
single capacitor complying with 14.2.1 b)
Y Capacitors (CY1, CY2 and
CY4) used between primary
and secondary circuit.
CY4) used between primary
and secondary circuit.
P
8.7
This clause is void
—
8.8
Basic or supplementary insulation > 0,4 mm (mm) :
Thickness of transformer
bobbin: 0.5mm
bobbin: 0.5mm
P
Reinforced insulation > 0,4 mm (mm) .................. :
See appended table 14 for
below information:
below information:
-
thickness of enclosure
-
optocoupler
P
Page 9 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
3 layers insulation tape
between primary winding and
secondary winding, also see
table 10.3.
between primary winding and
secondary winding, also see
table 10.3.
P
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
Double/reinforced insulation
between primary live parts and
accessible parts
between primary live parts and
accessible parts
P
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
Basic insulated secondary
wires can not touch hazardous
live parts
wires can not touch hazardous
live parts
P
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
P
8.11
Detaching of wires
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Primary wires connected to
power board by connector.
power board by connector.
Wires connected to power
board by connector and
amplifier board by soldering
after inserting into holes of
PCB with adhesive
additionally.
board by connector and
amplifier board by soldering
after inserting into holes of
PCB with adhesive
additionally.
P
Vibration test carried out ..................................... :
Yes
P
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
P
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
No such covers.
N/A
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
No such wires used.
N/A
8.18
Endurance test as required by 8.17
N/A
Page 10 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8.19
Disconnection from the mains
Mains plug/coupler used
P
8.19.1
Disconnect device
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
No such mains switch
N/A
8.20
Switch not fitted in the mains cord
Not fitted in the mains cord.
P
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
P
9.1
Testing on the outside
P
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
< 1000 V
N/A
9.1.1.1
a) Open circuit voltages
See appended table for max.
output of SPS.
output of SPS.
P
b) Touch current measured from terminal devices
using the network in annex D ...............................:
using the network in annex D ...............................:
(see appended table 9.1.1)
P
c) Discharge not exceeding 45
μC
< 45
μC
P
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or levers
P
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
4 mm x 100 mm test pin
P
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s .................:
of the mains plug; voltage (V) after 2 s .................:
Max. 28Vpeak measured after
2 s (limit: 35Vpeak)
2 s (limit: 35Vpeak)
P
If C is not greater than 0,1
μF no test needed
N/A
9.1.7
Resistance to external forces
P
a) Test probe 11 of IEC 61032 for 10 s (50 N)
N/A
b) Test hook of fig. 4 for 10 s (20 N)
N/A
c) 30 mm diameter test tool for 5 s (100 or 250 N)
100N
P
9.2
No hazard after removing a cover by hand
No such removable cover.
N/A
10
Insulation requirements
P
Page 11 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
10.1
Insulation resistance (MΩ) at least 2 MΩ min. after
surge test for basic and 4
surge test for basic and 4
MΩ min. for reinforced
insulation ............................................................:
No antenna connection.
N/A
10.2
Humidity treatment 48 h or 120 h .........................:
95% R. H., 40
o
C, 120h
(manufacturer requirement)
P
10.3
Insulation resistance and dielectric strength between
mains terminals
mains terminals
(see appended table)
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class I)
BASIC or SUPPLEMENTARY insulation (Class I)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
REINFORCED insulation (Class II)
P
11
Fault conditions
P
11.1
No shock hazard under fault condition
(see appended table 11.1)
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
No flames
N/A
No hazard from softening solder
No softening solder
N/A
Soldered terminations not used as protective
mechanism
mechanism
P
11.2.1
Measurement of temperature rises
(see appended table)
P
11.2.2
Temperature rise of accessible parts
(see appended table)
P
11.2.3
Temperature rise of parts, other than windings and
printed boards, providing electrical insulation
printed boards, providing electrical insulation
(see appended table)
P
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
P
11.2.5
Temperature rise of windings
(see appended table)
P
11.2.6
Temperature rise of printed boards shall not exceed
the limits of table 3 by max. 100 K for max. 5 min
the limits of table 3 by max. 100 K for max. 5 min
(see appended table)
P
Printed circuit boards (PCB) classified as V-0
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
according to 60695-11-10 or Clause G.1 may
exceed the limit in table 3 in case a) and b):
N/A
a) Temperature rise of printed circuit boards
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ............... :
exceeding the limits of table 3 by not more than
100 K for an area not greater than 2 cm² ............... :
N/A
b) Temperature rise of printed circuit boards
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
exceeding the limits of table 3 up to 300 K for an
area not greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
Click on the first or last page to see other CINEMA 610 service manuals if exist.