Report No.: 17032770 001 
 
 
TRF No. IEC60065K 
Pins +25V, GND of power 
board 
U2 (pin 4) open-
circuited 
10.1 
Pins +5V, GND of power 
board 
Normal 
5.92 
Pins +5V, GND of power 
board 
D8 short-circuited 
Wait for right circuit 
0* 
Pins +5V, GND of power 
board 
U2 (pin 3-4) short-
circuited 
0* 
Pins +5V, GND of power 
board 
U2 (pin 4) open-
circuited 
2.34 
Note: The touch current is measured according to 9.1.1.1 b) with the test circuit of Annex D connected 
between the specified points. For MIU measurement the measurement instruments are calibrated according 
to UL101. 
Input: 264V, 50Hz 
*  EUT shutdown immediately. 
 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0,9 or 1,1 times rated voltage  ............ :  240×1.1 = 264 
— 
 
Frequency (Hz) ................................................... :  50Hz 
— 
 
Ambient temperature (
o
C)  ................................... :  25.5 
— 
Test 
No. 
Com-
ponent No. 
Fault 
Test 
voltage  
Test 
time 
fuse 
No. 
Current (A)  Result 
Unit 
Ventilation 
openings 
Block
ed 
264 
4hrs 
F1 
0.191 
Normal operation. No hazards. No 
damage.  
For temperature measurement, 
see the bottom of this table. 
Bass 
S-C 
264 
10mins 
F1 
0.191 
-> 0.002 
EUT shutdown immediately. No 
hazards. No damage. 
Bass with 
max. 
attainable 
non-clipped 
output 
power 
-- 
264 
4.5hrs 
F1 
0.191 
-> 0.830 
EUT normal operation. No hazards. 
No damage.  
For temperature measurement, 
see the bottom of this table. 
Power board 
Bridge 
diode 
(BD1)  
pin1-2 
S-C 
264 
1S 
F1 
0.191 -> 0 
Fuse open instantly, no hazards, 
no damage. 
C1 
S-C 
264 
1S 
F1 
0.191 -> 0 
Fuse open instantly, no hazards, 
no damage. 
R18 
S-C 
264 
10mins  F1 
0.191 
Unit operated normally, no 
damaged, no hazards. 
 
 
 
 
 
Page 29 of 99 
 
 
 
Report No.: 17032770 001 
 
 
TRF No. IEC60065K 
C4 
S-C 
264 
10mins  F1 
0.191  
-> 0.003 
Unit shutdown instantly, no 
hazards, no damage. Recoverable. 
R38 
S-C 
264 
10mins  F1 
0.191 
Unit operated normally, no 
damaged, no hazards. 
U1 pin1-3 
S-C 
264 
1S 
F1 
0.191 -> 0 
Fuse open instantly, no hazards, 
no damage. 
10 
U1 pin1-7 
S-C 
264 
1S 
F1 
0.191  
-> 0.003 
Unit shutdown instantly, no 
hazards, no damage. Recoverable. 
11 
U2 pin3-4 
S-C 
264 
10mins  F1 
0.191  
-> 0.003 
Unit shutdown instantly, no 
hazards, no damage. 
12 
U2 pin1-2 
S-C 
264 
10mins  F1 
0.191  
-> 0.003 
Unit shutdown instantly, no 
hazards, no damage. 
13 
U2 pin4 
O-C 
264 
10mins  F1 
0.191  
-> 0.002 
Unit shutdown instantly, no 
hazards, no damage. 
14 
U3 pin3-4 
S-C 
264 
10mins  F1 
0.191  
-> 0.003 
Unit shutdown instantly, no 
hazards, no damage. 
15 
U3 pin1-2 
S-C 
264 
10mins  F1 
0.191  
-> 0.003 
Unit shutdown instantly, no 
hazards, no damage. 
16 
U3 pin4 
O-C 
264 
10mins  F1 
0.191 
Unit operated normally, no 
damaged, no hazards. 
17 
Q4(G-D) 
S-C 
264 
1S 
F1 
0.191 
Unit operated normally, no 
damaged, no hazards. 
18 
Q4 (G-S) 
S-C 
264 
10mins  F1 
0.191 
Unit operated normally, no 
damaged, no hazards. 
19 
Q4 (D-S) 
S-C 
264 
1S 
F1 
0.191 
Unit operated normally, no 
damaged, no hazards. 
20 
Q1 (G-D) 
S-C 
264 
1S 
F1 
0.191 -> 0 
Fuse open instantly, no hazards, 
no damage. 
21 
Q1 (D-S) 
S-C 
264 
1S 
F1 
0.191 -> 0 
Fuse open instantly, no hazards, 
no damage. 
22 
Q1 (G-S) 
S-C 
264 
1S 
F1 
0.191  
-> 0.002 
Unit shutdown instantly, no 
hazards, no damage. Recoverable. 
23 
T1 Sec. 
(pin 4-5) 
S-C 
264 
10mins  F1 
0.191  
-> 0.301 
-> 0.002 
Unit shutdown after 7mins, no 
hazards, no damage. 
24 
T1 Sec. 
(pin 10-12)  S-C 
264 
10mins  F1 
0.191  
-> 0.309 
-> 0.003 
Unit shutdown after 5mins, no 
hazards, no damage. 
25 
T1 Sec. 
(pin 9-12) 
S-C 
264 
10mins  F1 
0.191  
-> 0.309 
-> 0.003 
Unit shutdown after 5mins, no 
hazards, no damage. 
26 
T1 Sec. 
(pin 11-12)  S-C 
264 
30mins  F1 
0.191  
-> 0.245 
Input power increased, the audio 
output is normal, no hazards, no 
damage. 
For temperature measurement, 
see the bottom of this table. 
 
 
 
 
Page 30 of 99 
 
 
 
Report No.: 17032770 001 
 
 
TRF No. IEC60065K 
27 
D3/D2 
S-C 
264 
10mins  F1 
0.191  
-> 0.003 
Unit shutdown instantly, no 
hazards, no damage. Recoverable. 
28 
D8 
S-C 
264 
10mins  F1 
0.191  
-> 0.044 
Unit 
didn’t work instantly, no 
hazards, no damage. Recoverable. 
29 
T1 Sec. 
(pin 11 
after D8 to 
pin 12) 
O-L 
264 
9.5hrs 
F1 
0.191 
-> 0.271 
-> 0.306  
-> 0.062 
 
Unit shutdown when loaded to 
2.572A, recoverable. 
For temperature measurement, 
see the bottom of this table. 
30 
T1 Sec. 
(pin 10 
after D2 to 
pin 12) 
O-L 
264 
7.5hrs 
F1 
0.191 
-> 0.437 
-> 0.638  
-> 0.035 
 
Unit shutdown when loaded to 
2.57A, recoverable. 
For temperature measurement, 
see the bottom of this table. 
31 
+5V output 
S-C 
264 
10mins  F1 
0.191 
-> 0.003 
Unit shutdown instantly, no 
hazards, no damage. 
32 
+25V 
output 
S-C 
264 
10mins  F1 
0.191 
-> 0.003 
Unit shutdown instantly, no 
hazards, no damage. 
Decode board 
33 
Q4  
(pin S-D) 
S-C 
264 
5mins 
F1 
0.191 
-> 0.16 
Normal operation. No hazards, no 
damage. 
34 
U3  
(pin 1-3) 
S-C 
264 
10mins  F1 
0.191  
-> 0.072 
Unit shutdown instantly, no 
hazards, no damage. 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (
o
C)  ............................... :  -- 
— 
 
Ambient temperature t2 (
o
C)  ............................... :  -- 
— 
Temperature Rise dT 
of Part
 
dT (K) 
Limit max dT (K) 
Test No. 
01 
03 
25 
28 
29 
LF1 windings 
10.2 
28.1 
12.7 
17.0 
20.3 
175-45=130 
Transformer (T1) 
winding 
32.9 
74.4 
63.7 
90.8 
116.7 
175-10-45=120 
PCB near T1 
23.6 
47.4 
50.4 
47.0 
55.8 
150-(45-35)=140 
PCB near BD1 
19.2 
37.5 
25.7 
31.0 
37.8 
150-(45-35)=140 
Metal enclosure outside 
14.6 
19.6 
25.7 
14.4 
11.7 
65-(45-35)=55 
Ambient  
29.2 
28.4 
12.9 
29.2 
28.6 
-- 
Remark: S-C = short circuit, O-C = open circuit, O-L = overload  
Max. ambient operation temperature: 45
C. 
Hi-pot test between Primary and Secondary passed after above tests. 
 
 
 
 
 
Page 31 of 99 
 
 
 
Report No.: 17032770 001 
 
 
TRF No. IEC60065K 
 
13.2 
Table: working voltage measurement 
Location 
RMS voltage (V)  Peak voltage (V)  Comments  
 
T1 pin 1-9 
242 
368 
 
T1 pin 1-10 
243 
428 
 
T1 pin 1-11 
244 
356 
 
T1 pin 1-12 
243 
336 
 
T1 pin 2-9 
254 
448 
 
T1 pin 2-10 
250 
436 
 
T1 pin 2-11 
262 
368 
The highest Vrms 
T1 pin 2-12 
257 
368 
 
T1 pin 4-9 
180 
372 
 
T1 pin 4-10 
181 
392 
 
T1 pin 4-11 
181 
448 
The highest Vpeak 
T1 pin 4-12 
180 
364 
 
T1 pin 5-9 
180 
384 
 
T1 pin 5-10 
179 
380 
 
T1 pin 5-11 
182 
400 
 
T1 pin 5-12 
180 
416 
 
U2 pin 1-3 
188 
376 
 
U2 pin 1-4 
186 
376 
 
U2 pin 2-3 
187 
376 
 
U2 pin 2-4 
182 
376 
 
U3 pin 1-3 
180 
368 
 
U3 pin 1-4 
179 
368 
 
U3 pin 2-3 
180 
364 
 
U3 pin 2-4 
180 
364 
 
CY1 pri-sec 
114 
172 
 
CY2 pri-sec 
240 
364 
 
CY4 pri-sec 
243 
336 
 
 
Note: EUT supplied with 240V/60Hz. 
 
13.3 & 
13.4 
TABLES: clearances and creepage distances 
Rated supply voltage:  240V 
Pollution degree .. :  2 
Material Group .... : 
Ⅲ 
2 N force on internal parts applied: 
Yes 
30 N force on outside of conductive enclosure applied: 
Yes 
Location 
Working Voltage 
Clearance (mm) 
Creepage (mm) 
 
V rms 
V peak 
Min 
Actual 
Min 
Actual 
Across L and N before mains fuse F1 (B) 
250 
420 
2.0 
3.0 
2.5 
3.0 
Across mains fuse F1  (B) 
250 
420 
2.0 
3.0 
2.5 
3.0 
Primary component CON1 to secondary 
trace of ZD3 (R) 
250 
420 
4.0 
9.0 
5.0 
9.0 
Primary component (CX1 trace and body) to 
accessible metal screw (R) 
250 
420 
4.0 
5.1 
5.0 
5.1 
Primary trace of C1 to accessible metal 
screw (R) 
250 
420 
4.0 
5.1 
5.0 
5.1 
Page of 108
Display

Click on the first or last page to see other CINEMA 610 service manuals if exist.