Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
11.2.7
Temperature rise of parts not subject to the limits of
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e),"Fault conditions".
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e),"Fault conditions".
P
12
Mechanical strength
P
12.1.1
Bump test where mass >7 kg
> 7 kg
P
12.1.2
Vibration test
P
12.1.3
Impact hammer test
0.5J, 3times
(After tested, no damage and
EUT can withstand the
dielectric strength test as
specified in 10.3)
EUT can withstand the
dielectric strength test as
specified in 10.3)
P
Steel ball test
2J, 1time
(After tested, no damage and
EUT can withstand the
dielectric strength test as
specified in 10.3)
EUT can withstand the
dielectric strength test as
specified in 10.3)
P
12.1.4
Drop test for portable apparatus where mass ≤ 7 kg Not portable
N/A
12.1.5
Thermoplastic enclosures stress relief test
70°C, 7h applied.
P
12.2
Fixing of knobs, push buttons, keys and levers
Checked knobs in secondary
circuits, no hazards
circuits, no hazards
P
12.3
Remote controls with hazardous live parts
No such remote controls.
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
Clearances and creepage distances
P
13.1
Clearances in accordance with 13.3
(see appended table 13.3 &
13.4)
13.4)
P
Creepage distances in accordance with 13.4
P
13.2
Determination of working voltage
(see appended table 13.2)
P
13.3
Clearances
(see appended table 13.3 &
13.4)
13.4)
P
13.3.1
General
P
13.3.2
Circuits conductively connected to the mains comply
with table 8 and, where applicable, table 9 ............:
with table 8 and, where applicable, table 9 ............:
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
N/A
13.3.4
Measurement of transient voltages
N/A
Page 13 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
13.4
Creepage distances
(see appended table 13.3 &
13.4)
13.4)
P
Creepage distances greater than table 11 minimum
values
values
P
13.5
Printed boards
P
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
P
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
Temperature cycle test and dielectric strength test
N/A
500V test for transformers, magnetic coupler and
similar devices, if insulation is relied upon for safety
similar devices, if insulation is relied upon for safety
N/A
13.7
Enclosed, enveloped or hermetically sealed parts
not conductively connected to the mains, clearances
and creepage distances as in table 12
not conductively connected to the mains, clearances
and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
Approved optocoupler
– see
appended table 14.
P
14
Components
P
14.1
Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
(see appended table)
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved ............................:
Yes / No
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved :
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14:2005 ........... : Y1-Capacitor.
P
14.2.2
X capacitors tested to IEC 60384-14:2005 ........... : X2-Capacitor.
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 .................... :
connected to the mains: tests for X2 .................... :
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................ :
short-circuit current exceeds 0,2 A: compliance with
IEC 60384-1, 4.38 category B or better ................ :
N/A
Page 14 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better .............................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better .............................................:
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ..................................................................:
metal ..................................................................:
Yes, metal cased capacitors.
P
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Tested with appliance
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type .............................:
manufacturer's name and type .............................:
(see appended table 14)
P
Transformers and inductors separately approved . :
No
N/A
14.3.2
General
P
Insulation material complies with clause 20.1.4
P
14.3.3
Constructional requirements
P
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4
Separation between windings
See Appendix 1
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation) ............................ :
between hazardous live parts and accessible parts
(double or reinforced insulation) ............................ :
P
Coil formers and partition walls > 0,4 mm
Min. 0.5mm
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5
Insulation between HAZARDOUS LIVE parts and
ACCESSIBLE parts
ACCESSIBLE parts
P
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
between hazardous live parts and accessible parts
(double or reinforced insulation)
P
Coil formers and partition walls > 0,4 mm
Min. 0.5mm
P
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
N/A
Page 15 of 99
Report No.: 17032770 001
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
Fuse F1 used.
P
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
(see appended table 14)
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ...:
F1: T4AL 250V
P
14.5.2.3
Not possible to connect fuses in parallel ...............:
No such fuse holder used
N/A
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .........:
replacing fuse-links without the use of a tool .........:
Not replaceable.
N/A
14.5.3
PTC thermistors comply with IEC 60730-1:2007
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
N/A
14.6
Switches
No such switch.
N/A
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
and V-0 in annex G, G.1.1
N/A