JBL AVA 7 EMC - CB Certificate ▷ View online
page 5 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation
≤ 36 pA/kg (0.5 mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825 ....... :
N/A
Emission limits under fault conditions
N/A
7
HEATING UNDER NORMAL OPERATING CONDITIONS (See appended table)
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
N/A
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
N/A
page 6 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
P
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
Not used.
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
P
8.5
Class
Ι equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
P
Capacitors bridging basic insulation complying with
14.2.1a
14.2.1a
N/A
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
Class
ΙΙ equipment and Class ΙΙ constructions
within Class
Ι equipment
P
8.6
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
Between unearthed sec. parts
and hazardous live parts
and hazardous live parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Transformers P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
2 capacitors in series complying with 14.2.1 a)
2 capacitors in series complying with 14.2.1 a)
N/A
Reinforced or double insulation being bridged with
a single capacitor complying with 14.2.1 b)
a single capacitor complying with 14.2.1 b)
N/A
8.7
Basic insulation between parts at 35 V to 71 V (peak)
a.c. or 60 V to 120 V d.c. and accessible parts
a.c. or 60 V to 120 V d.c. and accessible parts
This clause is not considered
N/A
Reinforced or double insulation between circuits
operating at between 35 V and 71 V (peak) a.c. or
between 60 V and 120 V d.c. and hazardous live
parts at higher voltage
operating at between 35 V and 71 V (peak) a.c. or
between 60 V and 120 V d.c. and hazardous live
parts at higher voltage
N/A
Separation by Class
ΙΙ isolating transformer
N/A
Separation by Class
Ι transformer
N/A
Separation by earthed conductive part
N/A
page 7 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
8.8
Basic or supplementary insulation
≥ 0.4 mm (mm) : Main transformer:
Two plastic tubes (0.4 mm) are
supplementary insulation (with
glass fibre on the inside) on
prim lead-in wires passing
through the sec winding.
supplementary insulation (with
glass fibre on the inside) on
prim lead-in wires passing
through the sec winding.
Thermostat wires is basic
insulation 0.7 mm (
insulation 0.7 mm (
+ min 5 mm
clearance/creepage distance in
main transformer).
main transformer).
P
Reinforced insulation
≥ 0.4 mm (mm) ................... : Transformer T1 bobbin
P
Thin sheet insulation
In main transformer and T1
P
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers
any two of which meet 10.3
any two of which meet 10.3
N/A
Reinforced insulation, two layers each of which
meet 10.3
meet 10.3
2 layers black plastic tape in
main transformer (between
prim solder terminations
(thermal cut-out) to sec
winding.
main transformer (between
prim solder terminations
(thermal cut-out) to sec
winding.
P
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
3 layers electrical tape around
the transformer T1.
the transformer T1.
Main transformer:
1 layer plastic band and
2 layers black plastic tape in
main transformer (between
prim solder terminations
(thermostat) to accessible
parts.
1 layer plastic band and
2 layers black plastic tape in
main transformer (between
prim solder terminations
(thermostat) to accessible
parts.
3 layers transparent plastic
band insulation in main
transformers (between prim
and sec windings)
band insulation in main
transformers (between prim
and sec windings)
P
8.9
Adequate insulation between internal hazardous
live conductors and accessible parts
live conductors and accessible parts
Wires are fixed with cable ties
or have insulation tubing.
or have insulation tubing.
P
Adequate insulation between internal hazardous
live parts and conductors connected to accessible
parts
live parts and conductors connected to accessible
parts
No sec wire can come into
contact with live bare parts.
contact with live bare parts.
P
8.10
Double insulation between conductors connected
to the mains and accessible parts
to the mains and accessible parts
N
page 8 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
8.11
Detaching of wires
No undue reduction of creepage or clearance
distances if wires become detached
distances if wires become detached
Prim. and sec. wires secured
with flat pin and mating locking
connectors. No risk of any wire
becoming detached.
with flat pin and mating locking
connectors. No risk of any wire
becoming detached.
N/A
Vibration test carried out ....................................... : No, no need.
N/A
8.12
Adequate cross-sectional area of internal wiring to
mains socket-outlets
mains socket-outlets
N/A
8.13
Adequate fastening of windows, lenses, lamp
covers etc. (pull test 20 N for 10 s)
covers etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (pull test 50 N, for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal
wiring due to hot parts or sharp edges
wiring due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A