JBL AVA 7 EMC - CB Certificate ▷ View online

 
page 5 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
6 HAZARDOUS 
RADIATION 
 
6.1 
Ionizing radiation 
≤ 36 pA/kg (0.5 mR/h) 
 N/A 
6.2 
Laser radiation, emission limits to IEC 60825 ....... :  
N/A 
 
Emission limits under fault conditions 
 
N/A 
 
HEATING UNDER NORMAL OPERATING CONDITIONS (See appended table) 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
 N/A 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0.2 A at least 150 ºC 
 N/A 
 
 
page 6 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
PCB P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
 P 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
Not used. 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
 P 
8.5 
Class 
Ι equipment 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 P 
 
Capacitors bridging basic insulation complying with 
14.2.1a 
 N/A 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
 
Class 
ΙΙ equipment and Class ΙΙ constructions 
within Class 
Ι equipment 
 P 
8.6 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
Between unearthed sec. parts 
and hazardous live parts 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
Transformers P 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
 N/A 
8.7 
Basic insulation between parts at 35 V to 71 V (peak) 
a.c. or 60 V to 120 V d.c. and accessible parts 
This clause is not considered 
N/A 
 
Reinforced or double insulation between circuits 
operating at between 35 V and 71 V (peak) a.c. or 
between 60 V and 120 V d.c. and hazardous live 
parts at higher voltage 
 N/A 
 
Separation by Class 
ΙΙ isolating transformer 
 N/A 
 
Separation by Class 
Ι transformer 
 N/A 
 
Separation by earthed conductive part 
 
N/A 
 
page 7 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
8.8 
Basic or supplementary insulation 
≥ 0.4 mm (mm) : Main transformer: 
Two plastic tubes (0.4 mm) are 
supplementary insulation (with 
glass fibre on the inside) on 
prim lead-in wires passing 
through the sec winding. 
Thermostat wires is basic 
insulation 0.7 mm (
+ min 5 mm 
clearance/creepage distance in 
main transformer).
 
 
Reinforced insulation 
≥ 0.4 mm (mm)  ................... : Transformer T1 bobbin 
 
Thin sheet insulation 
In main transformer and T1 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
 
N/A 
 
Basic or supplementary insulation, three layers 
any two of which meet 10.3 
 N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
2 layers black plastic tape in 
main transformer (between 
prim solder terminations 
(thermal cut-out) to sec 
winding.  
 
Reinforced insulation, three layers any two which 
meet 10.3 
3 layers electrical tape around 
the transformer T1. 
Main transformer: 
1 layer plastic band and  
2 layers black plastic tape in 
main transformer (between 
prim solder terminations 
(thermostat) to accessible 
parts.  
3 layers transparent plastic 
band insulation in main 
transformers (between prim 
and sec windings) 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
Wires are fixed with cable ties 
or have insulation tubing. 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
No sec wire can come into 
contact with live bare parts.  
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
 N 
 
page 8 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
8.11 
Detaching of wires 
 
No undue reduction of creepage or clearance 
distances if wires become detached 
Prim. and sec. wires secured 
with flat pin and mating locking 
connectors. No risk of any wire 
becoming detached. 
N/A 
 
Vibration test carried out  ....................................... : No, no need. 
N/A 
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
 N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 N/A 
8.14 
Adequate fastening of covers (pull test 50 N, for 
10 s) 
 P 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
 P 
8.16 
Only special supply equipment can be used 
 
N/A 
 
Page of 55