page 21 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
20.2 
Fire enclosure 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to FV 1 
 N/A 
20.2.2 
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N/A 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 N/A 
A.10.2.2 
Humidity treatment carried out for 7 days 
 
N/A 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
B.5.4.1 
e) Where the separation of TNV circuits from other 
circuits relies on protective earthing the 
instructions make it clear that protective earthing is 
essential 
 N/A 
B.8.1 
TNV circuits separated from the mains circuit and from hazardous live parts by either: 
N/A 
 
a) double or reinforced insulation 
 
N/A 
 
b) basic insulation with earthed protective screening 
 N/A 
B.8.2 
TNV circuits separated from circuits other than 
those in B.8.1 and from accessible conductive 
parts by basic insulation meeting the requirements 
for clearances and creepage distances for the 
voltages concerned 
 N/A 
B.9.1.1 
TNV circuit terminals contacts which cannot be touched 
by probe B.1, exempt from the requirements 
inaccessible terminal contacts in 9.1.1 
 N/A 
B.10.1 
Insulation between TNV terminals and antenna 
terminals (including interconnection terminals which may 
be connected to equipment with antenna terminals) 
withstands the 50 discharges of 10.1 
 N/A 
B.14.12 
Surge suppressors between TNV circuits and 
other parts of the equipment have breakdown 
voltage at least 1.8 times the mains voltage 
 N/A 
 
page 22 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
 
 
 
position of the functional switch (W) ...................... : Stand-by 1.1 
 
Operating conditions 
1/8 of max. non-clipping output power (pink noise). The product was built-in acc. to cl. 4.2.1 except that it 
was positioned with a free space of 10cm along the sides, top and back acc. to Users Manual.  
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
254.4 2.70  520 7 
15 
198 2.66 390   
 
 
Loudspeaker impedance (
Ω) ................................ : 8Ω 
 
 
Several loudspeaker systems 
7 channels 
 
 
Marking of loudspeaker terminals 
Minimum Impedance 8 Ohms 
 
monitored point: 
dT (K) 
Permitted dT (K) 
Supply wiring insulation (Not under mechanical stress.) 
22 
60 (50) 
Iron core Main transformer  
38 
— 
Iron core T1 
26 
— 
Iron core Line filter 
16 
— 
Amplifier PCB  
40 
85 (75) 
Thermistor (surge current limiter), Amp. Heat sink 
42 
— 
Button (plastic) 
15 
50 (40) 
Enclosure, rear of top (metallic) 
30 
40 (30) 
Enclosure, middle of top (metallic) 
28 
40 (30) 
Enclosure, front of top (metallic) 
16 
40 (30) 
Enclosure, right side (metallic) 
17 
40 (30) 
Enclosure, middle of ventilation hole right side  
(metallic, not likely to be touched) 
21 
65 (55) 
Enclosure, front (metallic) 
16 
40 (30) 
Permitted dT (K) parenthesis is limit for tropical countries. 
 
page 23 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
Winding temperature rise measurements 
 
Ambient temperature t1 (ºC)  ................................. : 22 
 
 
Ambient temperature t2 (
°C) ................................. : 25 
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
Main Transformer Primary winding 
1.7427 2.0677  48  85 (75) 
Main Transf. Sec.wind. ch.1 orange/black 
0.4299 0.5080  47  85 (75) 
Main Transf. Sec.wind.ch.1 
red/grey
 0.4322 
0.5092 
46 
85 
(75) 
T1 Primary winding 
1617.1 
1832.4 
34 
85 (75) 
T1 Secondary winding 1 
5.99 
6.81 
35 
85 (75) 
T1 Secondary winding 2 
5.98 
6.79 
35 
85 (75) 
Permitted dT (K) parenthesis is limit for tropical countries. 
Note: the fan is mounted in a way that it brings in air from the sides and expels it at the rear side.  
 
page 24 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
7.2 
TABLE: softening temperature of thermoplastics 
N/A 
temperature T of part 
T - normal  
conditions (ºC) 
T - fault  
conditions (ºC) 
T softening 
(ºC) 
 
 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
insulation resistance R between: 
R (M
Ω) 
required R (M
Ω) 
Between the poles of the circuit directly connected to the 
supply mains. 
>10 min 
Reinforced insulation. 
>10 
min 4 
Basic insulation 
>10 min 
Main transformer prim-sec (reinforced insulation). 
>10 min 
 
10.3 TABLE: 
electric 
strength 
measurements 
test voltage applied between: 
test voltage (V) 
Breakdown 
Between the poles of the circuit directly connected to the 
supply mains. 
2120V peak 
No 
Reinforced insulation. 
4240V peak 
No 
Basic insulation. 
2120V peak 
No 
Main transformer prim-sec (reinforced insulation). 
4240V peak 
(break down 10 kV) 
No  
 
 
Page of 55
Display