DOWNLOAD JBL AVA 7 Service Manual ↓ Size: 2.72 MB | Pages: 55 in PDF or view online for FREE

Model
AVA 7
Pages
55
Size
2.72 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
ava-7.pdf
Date

JBL AVA 7 EMC - CB Certificate ▷ View online

 
page 25 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.06 times rated voltage  .......... : Rated 220-240V 
 
 
Ambient temperature (
°C) ..................................... : 22 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 22 
 
 
Ambient temperature t2 (ºC)  ................................. : 25 
 
Sc = shut circuit, d = disconnected 
No.  Component 
No. 
Fault 
Test voltage
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
- 100% 
output
 
254.4 5h 
 
14 min.
Sec F1/F2
each 
channel 
amplifier 
2.7/2.7 
I
in
=6.6A  P
in
=1360W 
Fuse in appliance inlet F1= 6.6A  
Fuse F1 Fan PCB prim = 0.4-1.9A
AC PCB fuse F1 = 21mA     
U
out
=31V  P
out
=120W 
After 1h 18min main transformer 
shut down (thermal cut-out) after 
52 min it switched on again 
automatic. After 3h 10min the 
thermal cut-out in transformer 
opened again. Repeated in a 
cycle. Max temperature rises was 
measured after 5h 14min: 
Main transf prim winding dT= - K  
Main transf sec.wind. dT= 98-100K
T1 wind. dT=40K 
T1 wind. dT=43K 
PCB dT=56K  
Heatsink thermistor dT=45K 
Enclosure, rear part top dT=29K      
Enclosure, front dT=23K 
Knobs plastic dT=19K             
No hazard. 
2 Speaker 
output 
(any 
channel) 
sc 
254.4 - - - 
Channel 
circuit 
protection 
shut 
down immediately, after 5 s 
channel continued to switch off 
and on in a cycle.  
No hazard.  
 
page 26 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
No.  Component 
No. 
Fault 
Test voltage
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
Fan 
locked 
left fan 
254.4 1h 
 
30 min.
Sec F1/F2
each 
channel 
amplifier 
1.0/1.0 
I
in
=2.7-1.6A  P
in
=520-305W 
Fuse in appliance inlet F1= 2.7A  
Fuse F1 Fan PCB prim = 0.4-1.9A
AC PCB fuse F1 = 21mA     
U
out
=11V  P
out
=15W 
After 23min. five channels on and 
after 1h 30min. three channels on. 
Max temperature rises: 
Mains transf. winding dT=36K 
T1 winding dT=45K 
PCB dT=35K  
Left fan motor unit dT=20K 
Enclosure, back part top dT=29K 
Enclosure, front dT=13K           
No remarks. 
Ventilation 
Vent. 
holes 
covered 
254.4 4h 
Sec F1/F2
each 
channel 
amplifier 
1.0/1.0 
I
in
=2.7-1.6A  P
in
=520-305W 
Fuse in appliance inlet F1= 2.7A  
Fuse F1 Fan PCB prim = 0.4-1.9A
AC PCB fuse F1 = 21mA     
U
out
=11V  P
out
=15W 
After 36min. five channels on and 
1h 6min. two channels on.  
Max temperature rises: 
Main transf. winding dT=39-42K 
T1 winding dT=60K 
PCB dT=40K  
Enclosure, med. part top dT=32K 
Enclosure, front dT=26K           
No remarks. 
DBR1 
Channel 1 
(+ -  −) 
sc 
198 / 254.4
Mains fuse
>8.4 
Mains fuse opened immediately. 
No remarks.  
C16 
Channel 1 
 
sc 
198 / 254.4
Mains fuse
>8.4 
Mains fuse opened immediately. 
No remarks.  
 
page 27 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
No.  Component 
No. 
Fault 
Test voltage
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
D4 
Channel 1 
sc 254.4 1h 
Sec F1 
Sec F2 
channel 1 
amplifier 
4 - 12 
0 - 12 
in short 
times 
I
in
=2.66A  P
in
=390W 
Fuse in appliance inlet F1= 2.66A 
Fuse F1 Fan PCB prim = 0.4-1.9A
AC PCB fuse F1 = 21mA     
U
out
=11V  P
out
=15W 
Channel 1 circuit protection shut 
down immediately and channel 1 
continued to switch off and on in a 
cycle. After 1 hour max temp.rises: 
Main transf iron core dT= 46K  
T1 iron core dT = 40K 
PCB dT = 38K  
Heatsink channel 1 dT = 40K 
No hazard. 
Q13  
(C – E) 
(Channel 1) 
sc 198 
20 
min.
Sec F1 
Sec F2 
channel 1
 
<8.4 
>8.4 
Power in 1 min. I
in
=5A, P
in
= 819W  
F1/F2 Amp. Ch.1 =10 and after  
1 min. F2 opened. U
out  
channel
 
1
 
0V. After 20 min. max temp. rises:
Main transf iron core dT= 19K  
T1 iron core dT = 6K 
Heatsink DBR1 channel 1 dT=24K
No hazard. 
Q18  
(C – E) 
(Channel 1) 
sc 198 1h 
 
10 min.
Sec F1 
Sec F2 
channel 1
 
>8.4 
<8.4 
I
in
=2.7A, P
in
= 380W.   
U
out  
channel
 
1
 
= 0V, F1 in channel 
1 opened immediately. After 1h 10 
min. max temp. rises: 
Main transf iron core dT= 46K  
T1 iron core dT = 26K 
PCB under R51-R53  channel 1 dT 
= 104K, Q18 channel 1 dT= 27K 
No hazard. 
10 
C14 
(Channel 1) 
sc 
198 / 254.4
1h 
Sec F1/F2
channel 1
 
0/0 
Ch.1, R32
 opened immediately and 
secondary components damage.  
No high temp. in channel 1 amp.    
No hazard.       
11 
D1 
(+ -  −) 
sc 
198 / 254.4
Fan PCB Fuse F1 opened 
immediately. When fans not 
operate, circuit protection for amp. 
channel shut down.  
No high temperature. 
No remarks.  
      No hazard. 
12 
C1 
sc 
198 / 254.4
Fan PCB Fuse F1 opened 
immediately.            No hazard. 
 
page 28 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
14 
TABLE: list of critical components and materials 
Object/part No. 
Manufacturer/ 
trademark 
Type/model 
Technical data 
Standard 
Mark(s) of 
conformity 
Main 
Transformer (R) 
Amplifier 
Technologies 
56-0271 
240V, 50Hz 
IEC 60065 
Tested in the 
appliance 
Thermal cut-out 
(in main transf.) 
PEPI Type 
J 130°C 
IEC 
60730-1 
 
Accepted in the 
appliance 
Plastic part 
inside main 
transformer 
MDE Nylon 
N6050L, 
N6050HSL 
94V-2 Complies 
with 
FH3-40mm/min 
(IEC 60707:81) 
Accepted in the 
appliance 
Standby 
Transformer  T1 
MCI Transformer 
Corp. 
4-44-3024 
115/230V 
IEC 60065 
Tested in the 
appliance 
Bobbin Standby 
Transformer  T1 
E.I. Dupont De 
Nemours Co. 
FR-530 0.8 
mm 
Complies 
with 
FH3-40mm/min 
(IEC 60707:81) 
Accepted in the 
appliance 
Alt. Standby 
Transformer  T1 
Tamura PL2.5-24-130B 
115/230V, 
50/60Hz 
IEC 60065 
Tested in the 
appliance 
Bobbin in  
Alt. Standby 
Transformer  T1 
E.I. Dupont De 
Nemours Co. 
FR-530 0.8 
mm 
Complies 
with 
FH3-40mm/min 
(IEC 60707:81) 
Accepted in the 
appliance 
AC board PCB 
Amplifier 
Technologies Inc 
17-JBL-AV7-6 V-0 
 
Complies with 
FV-1  
(IEC 60707:81) 
Accepted in the 
appliance 
AC Line Inductor 
Elytone 
YT-15629 ELY 
IEC 60065 
Tested in the 
appliance 
Inductor bobbin 
EI Dupont De 
Nemours 
70G33L 94HB 
Complies 
with 
FH3-40mm/min 
(IEC 60707:81) 
Accepted in the 
appliance 
Inductor board 
PCB 
Jiangsu Suang 
Electronics Co., 
Ltd. 
SH-. 
 
V-0 
(E154554) 
Complies with 
FV-1  
(IEC 60707:81) 
Accepted in the 
appliance 
Thermal cut-out, 
on amplifier board 
(SELCO) 
Uchiya 
UP72 75°C 
IEC 
60065 
sub.cl. 14.5.1.1b)
 
Tested in the 
appliance 
Mains fuse (in 
appliance inlet) 
Wickmann 
Group 
195 
T4AL, 250V 
IEC 60127 
 
Prim. Fuse F1  
(AC  PCB) 
Wickmann 
Group 
195 
T160mAL, 250V
IEC 60127 
 
Sec. Fuse F1/F2 
(on amp. PCB) 
Wickmann 
Group 
195 T6.3AL, 
250V 
IEC 
60065 
 
Capacitor C7 
(across K1, K2) 
Murata KH 
X1, 
0.01µF, 
250V 
IEC 60384-14  
2-edition 
 
Appliance inlet 
Schurter AG 
KEC… 
10A 250V 
IEC 60320 
 
Page of 55