JBL AVA 7 EMC - CB Certificate ▷ View online
page 13 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.3.3.1
Clearances and creepage distances according to
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
14.3.4.1
Class
ΙΙ transformers have adequate separation
between hazardous live windings and accessible
windings (double or reinforced insulation)
windings (double or reinforced insulation)
Prim-sec (main):
creepage dist/clearance: 9.5mm
(3 layers plastic band).
Prim-sec (T1):
4-44-3024: 9.5mm
PL2.5-24-130B: 9.6mm
4-44-3024: 9.5mm
PL2.5-24-130B: 9.6mm
P
Coil formers and partition walls
≥ 0.4 mm
1.6mm (T1)
P
14.3.4.2
Class
Ι transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
14.3.5.1
Class
ΙΙ transformers have adequate insulation
between hazardous live windings and accessible
parts (double or reinforced insulation)
parts (double or reinforced insulation)
T1:
Prim - sec (via iron core):
min. 5.1 mm + 3 layers tape
around iron core
Prim - sec (via iron core):
min. 5.1 mm + 3 layers tape
around iron core
(Iron core of T1 is not connected
to accessible parts)
to accessible parts)
Line filter:
Prim.– iron core (no accessible
parts) = 3 mm
Prim.– iron core (no accessible
parts) = 3 mm
P
Coil formers and partition walls
≥ 0.4 mm
0.8 mm (T1)
1.0 mm (line filter)
P
14.3.5.2
Class
Ι transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category FV 1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
page 14 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.5
Protective devices
Protective devices used within their ratings
P
External clearance and creepage distances
appropriate for the voltage across the device when
opened
appropriate for the voltage across the device when
opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the
submission
submission
Located in main transformer.
Located on amplifier PCB
Located on amplifier PCB
P
14.5.1.2
a) Thermal links separately approved
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices resettable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
IEC 60127
Mains fuse, F1 (AC PCB)
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : T4AL 250V
(rear side mains fuse
in appliance inlet)
T160mAL 250V
(internal mains
fuse AC PCB)
T2AL 250V
(internal mains fuse
FAN PCB)
T6.3AL 250V
(Amplifier module
fuses)
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ........ :
replacing fuse-links without the use of a tool ........ :
P
14.5.3
PTC-S thermistors comply with IEC 60738
N/A
PTC-S devices (15 W) category FV 1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
N/A
page 15 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.6
Switches
(See appended table)
14.6.1 Permanently
connected
equipment
provided
with
an all-pole mains switch unless 5.4.2 is met
N/A
14.6.2
Manually operated mechanical switch (MOMS),
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
No N/A
Switch readily accessible and not in mains cord
N/A
Exception for automatic switching
Can be controlled by data link
P
Exception for continuous operation
N/A
14.6.3
Manually operated mechanical switch (MOMS):
switch indication On position clearly discernible
switch indication On position clearly discernible
(Blue LED’s on standby switch)
N/A
Indication by marking meets Cl. 5
N/A
Indication
of
the
OFF
position
N/A
14.6.4
Manually operated mechanical switch (MOMS)
fitted, is there a Stand-by mode ............................ :
fitted, is there a Stand-by mode ............................ :
N/A
Stand-by mode clearly discernible ........................ : (Red LED‘s on standby switch)
N/A
Exception for low Stand-by current < 0.7 mA (peak)
N/A
14.6.5
Components bridging contacts of mains switches
comply with 14.1 a) or 14.2.2
comply with 14.1 a) or 14.2.2
N/A
14.6.6
Manually operated mechanical switches (MOMS)
separately approved to IEC 61058-1
separately approved to IEC 61058-1
N/A
Manually operated mechanical switch (MOMS)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
Peak surge current for relays:
K1 = 70A (measured)
K2 = 7A (measured)
K1 = 70A (measured)
K2 = 7A (measured)
P
14.7
Safety interlocks
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9
Motors
14.9.1
Endurance test on motors
Low voltage fan motor
N/A
Motor
start
test
N/A
Dielectric
strength
test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
P
14.9.4
Motors with phase-shifting capacitors, three-phase
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60950, Annex B
motors and series motors meet Cl. B.8, B.9 and
B.10 of IEC 60950, Annex B
N/A
page 16 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.10
Batteries
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
N/A
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.11
Optocouplers
Optocouplers comply with Cl. 8
N/A
N/A
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
(see list of critical components)
P
15.1.2
Connectors for antenna, earth, audio, video or data:
No risk of insertion in mains socket-outlets
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
N/A
15.1.3
Output terminals of AC adaptors or similar devices
not compatible with household mains socket-
outlets
not compatible with household mains socket-
outlets
N/A
15.2
Provision for protective earthing
Accessible conductive parts of Class
Ι equipment
reliably connected to earth terminal, within
equipment
equipment
P
Class
Ι supply equipment with non-hazardous live
output voltage: output circuit not connected to
earth
earth
N/A
Protective earth conductors correctly coloured
P
Equipment with non-detachable mains cord
provided with separate protective earth terminal
near mains input
provided with separate protective earth terminal
near mains input
N/A
Protective earth terminal resistant to corrosion
P
Earth resistance (
Ω) ≤ 0.1 Ω at 25 A ..................... : ≤ 0.03
P