JBL AVA 7 EMC - CB Certificate ▷ View online

 
page 13 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
14.3.3.1 
Clearances and creepage distances according to 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
14.3.4.1 
Class 
ΙΙ transformers have adequate separation 
between hazardous live windings and accessible 
windings (double or reinforced insulation) 
Prim-sec (main):  
creepage dist/clearance: 9.5mm 
(3 layers plastic band).  
Prim-sec (T1): 
4-44-3024: 9.5mm 
PL2.5-24-130B: 9.6mm 
 
Coil formers and partition walls 
≥ 0.4 mm 
1.6mm (T1) 
14.3.4.2 
Class 
Ι transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 N/A 
14.3.5.1 
Class 
ΙΙ transformers have adequate insulation 
between hazardous live windings and accessible 
parts (double or reinforced insulation) 
T1: 
Prim - sec (via iron core):  
min. 5.1 mm + 3 layers tape 
around iron core 
(Iron core of  T1 is not connected 
to accessible parts) 
Line filter:  
Prim.– iron core (no accessible 
parts) = 3 mm  
 
Coil formers and partition walls 
≥ 0.4 mm 
0.8 mm (T1) 
1.0 mm (line filter) 
14.3.5.2 
Class 
Ι transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N/A 
 
Component meets category FV 1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N/A 
 
page 14 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
 
External clearance and creepage distances 
appropriate for the voltage across the device when 
opened 
 P 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
Located in main transformer. 
Located on amplifier PCB  
14.5.1.2 
a) Thermal links separately approved 
 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices resettable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to 
IEC 60127 
Mains fuse, F1 (AC PCB) 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : T4AL 250V 
(rear side mains fuse 
in appliance inlet) 
T160mAL  250V 
(internal mains 
fuse AC PCB) 
T2AL  250V 
(internal mains fuse 
FAN PCB) 
T6.3AL  250V
 (Amplifier module 
fuses)
 
14.5.2.3 
Not possible to connect fuses in parallel ............... :  
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ........ :
 P 
14.5.3 
PTC-S thermistors comply with IEC 60738 
 
N/A 
 
PTC-S devices (15 W) category FV 1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 N/A 
 
 
page 15 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
14.6 
Switches 
     (See appended table) 
14.6.1 Permanently 
connected 
equipment 
provided 
with 
an all-pole mains switch unless 5.4.2 is met 
 N/A 
14.6.2 
Manually operated mechanical switch (MOMS), 
required where power consumption > 15 W and/or 
peak voltage > 4 kV; MOMS required ................... :
No N/A 
 
Switch readily accessible and not in mains cord 
 
N/A 
 
Exception for automatic switching 
Can be controlled by data link 
 
Exception for continuous operation 
 
N/A 
14.6.3 
Manually operated mechanical switch (MOMS): 
switch indication On position clearly discernible 
(Blue LED’s on standby switch) 
N/A 
 
Indication by marking meets Cl. 5 
 
N/A 
 Indication 
of 
the 
OFF 
position 
 
N/A 
14.6.4 
Manually operated mechanical switch (MOMS) 
fitted, is there a Stand-by mode  ............................ :
 N/A 
 
Stand-by mode clearly discernible  ........................ : (Red LED‘s on standby switch) 
N/A 
 
Exception for low Stand-by current < 0.7 mA (peak) 
 N/A 
14.6.5 
Components bridging contacts of mains switches 
comply with 14.1 a) or 14.2.2 
 N/A 
14.6.6 
Manually operated mechanical switches (MOMS) 
separately approved to IEC 61058-1 
 N/A 
 
Manually operated mechanical switch (MOMS) 
tested as part of the equipment complies with 
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8 
and/or 14.6.9 and Annex G (G1.1) 
Peak surge current for relays: 
K1 = 70A (measured) 
K2 = 7A (measured) 
14.7 
Safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
N/A 
14.8 
Voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 N/A 
14.9 
Motors 
14.9.1 
Endurance test on motors 
Low voltage fan motor 
N/A 
 Motor 
start 
test 
 
N/A 
 Dielectric 
strength 
test 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 
N/A 
14.9.3 
Protection against moving parts 
 
14.9.4 
Motors with phase-shifting capacitors, three-phase 
motors and series motors meet Cl. B.8, B.9 and 
B.10 of IEC 60950, Annex B 
 N/A 
 
page 16 of 37 
Ref.No.:503878 
  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
14.10 
Batteries 
14.10.1 
Batteries mounted with no risk of accumulation of 
flammable gases 
 N/A 
14.10.2 
No possibility of recharging non-rechargeable 
batteries 
 N/A 
14.10.3 
Recharging currents and times within 
manufacturers limits 
 N/A 
 
Lithium batteries discharge and reverse currents 
within the manufacturers limits 
 N/A 
14.11 
Optocouplers 
 
Optocouplers comply with Cl. 8 
 
N/A 
 
 
N/A 
 
15 TERMINALS 
 
15.1.1 
Mains plug, appliance inlet, interconnection 
couplers and mains socket-outlet meet the 
appropriate standard 
(see list of critical components) 
15.1.2 
Connectors for antenna, earth, audio, video or data: 
 
No risk of insertion in mains socket-outlets 
 
 
No risk of insertion into audio or video: outlets 
marked with the symbol of 5.2 
 N/A 
15.1.3 
Output terminals of AC adaptors or similar devices 
not compatible with household mains socket-
outlets 
 N/A 
15.2 
Provision for protective earthing 
 
Accessible conductive parts of Class 
Ι equipment 
reliably connected to earth terminal, within 
equipment 
 
Class 
Ι supply equipment with non-hazardous live 
output voltage: output circuit not connected to 
earth 
 N/A 
 
Protective earth conductors correctly coloured 
 
 
Equipment with non-detachable mains cord 
provided with separate protective earth terminal 
near mains input 
 N/A 
 
Protective earth terminal resistant to corrosion 
 
 
Earth resistance (
Ω) ≤ 0.1 Ω at 25 A ..................... : ≤ 0.03 