page 33 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
B.5.4.1
NO: marking required for equipment connected to
a communications network other than the public
telecommunications network, where separation
between the mains and the network relies upon a
safety earth connection
a communications network other than the public
telecommunications network, where separation
between the mains and the network relies upon a
safety earth connection
N/A
NO: marking to state equipment must be
connected to an earthed mains socket-outlet
connected to an earthed mains socket-outlet
N/A
SE: marking required on equipment connected to
a telecommunication network, where separation
between the mains and the network relies on
connection to protective earth
a telecommunication network, where separation
between the mains and the network relies on
connection to protective earth
N/A
SE: marking to state equipment must be
connected to an earthed mains socket-outlet
connected to an earthed mains socket-outlet
N/A
B.8.1
DK: method b) of 8.1 is permitted only for
permanently connected equipment
permanently connected equipment
N/A
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N/A
B.14.12
DK: surge suppressors between
telecommunications network and accessible parts
permitted only for permanently connected
equipment
telecommunications network and accessible parts
permitted only for permanently connected
equipment
N/A
NO: surge suppressors between TNV circuits and
accessible parts of Class
accessible parts of Class
Ι equipment permitted
only if the equipment is marked stating it must be
connected to an earthed mains socket-outlet
connected to an earthed mains socket-outlet
N/A
SE: surge suppressors between TNV circuits and
accessible parts of Class
accessible parts of Class
Ι equipment permitted
only if the equipment is marked stating it must be
connected to an earthed mains socket-outlet, the
marking text is: "Apparaten skall anslutas till jordat
uttag"
connected to an earthed mains socket-outlet, the
marking text is: "Apparaten skall anslutas till jordat
uttag"
N/A
page 34 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS
5
DE: additional markings required in German language:
N/A
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
N/A
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N/A
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: certification number on the back cover
N/A
6.1
DE: ionizing radiation from TV receivers not
exceeding 1
exceeding 1
µSv/h (= 7.2 pA/kg = 0.1 mR/h) at
10 cm
N/A
page 35 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
National differences SINGAPORE
IEC 60065, 6
th
edition
NOTE: (These differences are taken from IEC 60065:1993 and adopted to
IEC 60065:1998)
CB / SG 2004 I
Throughout the standard, whenever the words
"white pine board" appear, insert the words "or
plywood board" to it.
"white pine board" appear, insert the words "or
plywood board" to it.
P
SS143 Amendment No. 1 and No. 2
4.1.3
(4.1.3)*
Delete "45 % to 75 % and insert "65 ± 5 %".
75% maximum in IEC
60065:1998
60065:1998
P
7.1
(7.1)
Resistance to heat without external forces.
Adopt the temperature specified for the tropical
conditions.
conditions.
P
8.6
(9.3.4)
Delete the note "A Quality Assessment System
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
for capacitors complying with Subclause 14.2 is
under consideration in the IEC".
This is not in IEC 60065:1998
P
10.2
(10.2)
Humidity treatment
Adopt the testing conditions designed for tropical
conditions.
Adopt the testing conditions designed for tropical
conditions.
120h at a relative humidity
of 93%.
P
16
(16)
External flexible cords
Delete "IEC Publication 60227: Polyvinyl Chloride
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC publication 60245:
Rubber insulated Cables of rated up to and
including 450/750 V " and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Insulated Cables of Rated Voltages up to and
Including 450/750 V and IEC publication 60245:
Rubber insulated Cables of rated up to and
including 450/750 V " and insert "Singapore
Standard 236: Flexible Cords", whenever they
appear in this clause.
Delete "CEE Publication 13, CEE Publication 2
and IEC Publication 60173: Colours of the Cores
of Flexible Cables and Cords" whenever they
appear in this clause.
and IEC Publication 60173: Colours of the Cores
of Flexible Cables and Cords" whenever they
appear in this clause.
P
16.2
(16.2)
Delete the notes in small print and insert "A
nominal cross-sectional area of 0,75 mm² will
satisfy this requirement".
nominal cross-sectional area of 0,75 mm² will
satisfy this requirement".
This is not in IEC 60065:1998
P
page 36 of 37
Ref.No.:503878
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
16.3b
(16.4b)
Delete “Subclause 3.1 of IEC Publication 60227-
2: Part 2: Test Methods“ and insert “Subclause
9.1 of SS 236“:
2: Part 2: Test Methods“ and insert “Subclause
9.1 of SS 236“:
9.1 Flexing test (except for tinsel cords, twisted
twin and single core cords). The test shall be
carried out by means of the apparatus shown in
Figure 5. This apparatus has a carrier C
supporting two pulleys A and B arranged so that
the cord is horizontal between the pulleys. The
carrier moves backward and forward over a
distance of 1 m at an approximately constant
speed of 0.33 m/s.
twin and single core cords). The test shall be
carried out by means of the apparatus shown in
Figure 5. This apparatus has a carrier C
supporting two pulleys A and B arranged so that
the cord is horizontal between the pulleys. The
carrier moves backward and forward over a
distance of 1 m at an approximately constant
speed of 0.33 m/s.
A sample of flexible cord about 5 m long shall be
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
given in Table 1.
stretched over the pulleys as shown in the figure,
each end being loaded with a weight. The weight
and the diameter of the pulleys A and B shall be
given in Table 1.
Screen cords in accordance with Table 7 shall be
tested before application of the screen and outer
sheath.
tested before application of the screen and outer
sheath.
The pulleys shall have a semi-circular shaped
groove for circular cords and a flat groove for
parallel twin cords. The restraining clamps D shall
be fixed so that the pull is always applied by the
weight from which the carrier is moving away.
The carrier shall make 30 000 backward and
forward movements (60 000 single strokes). Each
conductor of the sample shall be loaded with the
current specified in Table 2.
For twin cords and for light PVC-sheated 3-core
cords, the voltage between the conductors shall
be approximately 230 V a.c. For all other cords
having three or more cores a three-phase a.c.
voltage of about 400 V shall be applied to three
conductors, any additional conductors being
connected to the neutral.
During the test no open-circuit in any core or
short-circuit between cores shall occur.
groove for circular cords and a flat groove for
parallel twin cords. The restraining clamps D shall
be fixed so that the pull is always applied by the
weight from which the carrier is moving away.
The carrier shall make 30 000 backward and
forward movements (60 000 single strokes). Each
conductor of the sample shall be loaded with the
current specified in Table 2.
For twin cords and for light PVC-sheated 3-core
cords, the voltage between the conductors shall
be approximately 230 V a.c. For all other cords
having three or more cores a three-phase a.c.
voltage of about 400 V shall be applied to three
conductors, any additional conductors being
connected to the neutral.
During the test no open-circuit in any core or
short-circuit between cores shall occur.
After the test, any sheath on cords having three
or more cores shall be removed. The cord, or the
laid up cores, shall then withstand the voltage test
specified in Subclause 8.2 or 8.3 as appropriate,
but with a test voltage not exceeding 2000 V.
or more cores shall be removed. The cord, or the
laid up cores, shall then withstand the voltage test
specified in Subclause 8.2 or 8.3 as appropriate,
but with a test voltage not exceeding 2000 V.
TABLE 1, TABLE 2, FIGURES 4 and 5, see the
CB BULLETIN
P
* in parenthesis: clauses acc. to IEC 60065:1993