3.4 Performance 
level 
 
The test results shall be classified in terms of the loss of function or degradation of performance of the equipment 
under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed 
between the manufacturer and the purchaser of the product. 
 
Definition related to the performance level: 
 
 
 
based on the used product standard 
 
 
based on the declaration of the manufacturer, requestor or purchaser 
 
Criterion A:  
Definition: normal performance within limits specified by the manufacturer, requestor or purchaser: 
 
The equipment shall continue to operate as intended during the test. No change of actual operating state (for 
example change of channel) is allowed as a result of the application of the test. The criterion of compliance with 
the requirement is a wanted to unwanted audio signal ratio of 
≥ 40 dB at a wanted audio signal level of 50 mW, 
or at another audio signal level specified by the manufacturer. No degradation of test picture is allowed. 
 
Criterion B:  
Definition: temporary loss of function or degradation of performance which ceases after the disturbance ceases, and from which the equipment 
under test recovers its normal performance, without operator intervention: 
 
After the test, the equipment shall continue to operate as intended without operator intervention. No loss of  
function is allowed after the test when the apparatus is used as intended, but failures which are recovered  
automatically but which cause temporary delay in processing, are permissible. No change of actual operating state
is allowed as a result of the application of the test. During the test, degradation of performance is allowed. 
 
Criterion C:  
Definition: temporary loss of function or degradation of performance, the correction of which requires operator intervention: 
 
 
 
 
 
Criterion D:  
Definition: loss of function or degradation of performance, which is not recoverable, owing to damage to hardware or software, or loss of data: 
 
 
 
 
 
 
 
File No. 
F25715-01-00BA
, page 8 of 28 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.4 
4   T E S T  E N V I R O N M E N T  
4.1 
Address of the test laboratory 
 
 
MIKES BABT Product Service GmbH 
 Ohmstrasse 
2-4 
 94342 
Strasskirchen 
 Germany 
 
 
 
 
4.2 Environmental 
conditions 
 
During the measurement the environmental conditions were within the listed ranges: 
 
Temperature: 
15-35 ° C 
 
 
 
 
Humidity: 30-60 
 
 
 
 
Atmospheric pressure: 
86-106 kPa 
 
 
 
 
4.3 
Statement of the measurement uncertainty 
 
The data and results referenced in this document are true and accurate. The reader is cautioned that there may 
be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated 
for all measurements listed in this test report acc. to CISPR 16-4-2 /11.2003 „Uncertainties, statistics and limit 
modelling – Uncertainty in EMC measurements“ and is documented in the MIKES BABT Product Service GmbH 
quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar 
to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued 
compliance of the device. 
 
  
 
 
File No. 
F25715-01-00BA
, page 9 of 28 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.4 
5   T E S T   C O N D I T I O N S   A N D   R E S U L T S  
5.1 Conducted 
disturbance 
For test instruments and accessories used see section 6 Part A 4
5.1.1 
Description of the test location 
 
Test location: 
 
5.1.2 
Photo documentation of the test set-up 
 
 
 
5.1.3 Test 
result 
 
Frequency range: 
0.15 MHz - 30 MHz 
 
Min. limit margin 
>5 dB 
 
The requirements are FULFILLED. 
 
Remarks: 
Only the worst results are shown, even all tests have been done.  
 
 
For detailed results, please see the following page(s).  
 
 
 
 
 
 
 
 File 
No. 
F25715-01-00BA
, page 10 of 28 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.4 
5.1.4 Test 
protocol 
 
Test point  
L1 
Operation mode: 
1 kHz - 1/8 power 
Remarks: N/A 
Date: 
15. April 05 
Tested by: 
Peter Bauer 
Result: passed 
 
 
Freq
QP- L
D -Limit 
Freq
AV-L
D -Limit 
Freq
QP- L
D -Limit 
Freq
AV-L
D -Limit 
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
160
46,1
19,4 no Result
200
41,4
22,2
250
35,9
25,9
335
35,1
24,2
370
34,6
23,9
450
34,5
22,4
570
35,2
20,8
665
31,9
24,1
dB [µV]
PK: 
AV:
QP:
 
AV: 
×
 0.15
1
10
20
30  [MHz]
 Detector:
Legend 
QP  LIMIT
AV   LIMIT
0
10
20
30
40
50
60
70
80
 
  