JBL AVA 7 (serv.man2) EMC - CB Certificate ▷ View online
File
No.
F25715-01-00BA
, page 11 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
Test point:
N
Operation mode:
1 kHz - 1/8 power
Remarks: N/A
Date:
Date:
15. April 05
Tested by:
Peter Bauer
Result: passed
Freq
QP- L
D -Limit
Freq
AV-L
D -Limit
Freq
QP- L
D -Limit
Freq
AV-L
D -Limit
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
kHz
dB[µV]
QP [dB]
kHz
dB[µV]
AV [dB]
165
44,6
20,6 no Result
190
42,3
21,7
230
36,2
26,2
dB [µV]
PK:
AV:
QP:
♦
AV:
×
0.15
1
10
20
30 [MHz]
Detector:
Legend
QP LIMIT
AV LIMIT
0
10
20
30
40
50
60
70
80
File
No.
F25715-01-00BA
, page 12 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
5.2 Disturbance
power
For test instruments and accessories used see section 6 Part A 7.
5.2.1
Description of the test location
Test location:
Shielded Room S7
5.2.2
Photo documentation of the test set-up
5.2.3 Test
result
Frequency range:
30 MHz - 300 MHz
Min. limit margin
>5 dB
The requirements are FULFILLED.
Remarks:
For detailed results, please see the following page(s).
File
No.
F25715-01-00BA
, page 13 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
5.2.4 Test
protocol
Test point:
AC power line
Operation mode:
1 kHz - 1/8 power
Remarks: N/A
Date:
Date:
24. Feb. 05
Tested by:
Peter Bauer
Result: passed
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
QP
AV
< 25 dBpW
File
No.
F25715-01-00BA
, page 14 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
Test point:
speaker cables
Operation mode:
1 kHz - 1/8 power
Remarks: N/A
Date:
Date:
24. Feb. 05
Tested by:
Peter Bauer
Result: passed
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
QP
AV
< 25 dBpW