5.4.4 Test
protocol
Operation mode:
pink noise - 1/8 power
Remarks: N/A
Date:
Date:
14. April 05
Tested by:
Peter Bauer
Result: passed
Testconditions: 230 V / 50 Hz / Phase: L1 / Observations: 24 x 1 min / Ztest: (0.40+j0.25) Oh
Time
Pmax
Pst
Sliding Plt d(t)>3.30% [s] dmax [%] dc [%] PASS FAIL
15:59:47
0.582
0.2060
- . - - - -
0.000
0.405
0.401
X
16:00:47
3.499
0.4190
- . - - - -
0.000
1.105
0.401
X
16:01:47
12.290
0.7170
- . - - - -
0.000
1.891
0.398
X
16:02:47
17.480
0.8610
0.6482
0.000
2.338
0.558
X
16:03:47
22.240
0.9630
0.7902
0.000
2.762
0.555
X
16:04:47
24.180
1.0110
0.9018
0.000
2.838
0.533
X
16:05:47
25.470
1.0300
0.9706
0.000
3.021
0.534
X
16:06:47
26.270
1.0420
1.0124
0.000
3.010
0.524
X
16:07:47
27.140
1.0690
1.0384
0.000
3.011
0.524
X
16:08:47
27.660
1.0770
1.0548
0.000
3.040
0.458
X
16:09:47
27.220
1.0640
1.0632
0.000
3.100
0.510
X
16:10:47
27.350
1.0680
1.0695
0.000
3.173
0.510
X
16:11:47
26.270
1.0430
1.0631
0.000
3.067
0.383
X
16:12:47
28.780
1.0970
1.0683
0.000
3.182
0.379
X
16:13:47
28.390
1.0920
1.0754
0.000
3.088
0.452
X
16:14:47
27.860
1.0800
1.0784
0.000
3.214
0.451
X
16:15:47
26.980
1.0580
1.0820
0.000
3.143
0.376
X
16:16:47
29.500
1.1070
1.0845
0.000
3.145
0.433
X
16:17:47
27.570
1.0750
1.0803
0.000
3.152
0.433
X
16:18:47
27.610
1.0770
1.0795
0.000
3.100
0.492
X
16:19:47
28.200
1.0870
1.0866
0.000
3.240
0.491
X
16:20:47
28.820
1.0970
1.0841
0.000
3.167
0.491
X
16:21:47
28.910
1.0990
1.0901
0.000
3.116
0.491
X
16:22:47
28.400
1.0920
1.0938
0.000
3.211
0.429
X
Limits:
1.000
0.650
0.500
6.000
3.300
Plt: 1.019297
Evaluated: dmax average (2.903 %)
FLICKER: Test PASS!
Time
Pmax
Pst
Sliding Plt d(t)>3.30% [s] dmax [%] dc [%] PASS FAIL
15:59:47
0.000
0.0140
- . - - - -
0.000
0.013
- . - - -
X
16:00:47
0.002
0.0340
- . - - - -
0.000
0.029
- . - - -
X
16:01:47
0.007
0.0590
- . - - - -
0.000
0.050
- . - - -
X
16:02:47
0.009
0.0680
- . - - - -
0.000
0.058
- . - - -
X
16:03:47
0.011
0.0760
- . - - - -
0.000
0.067
- . - - -
X
16:04:47
0.012
0.0780
- . - - - -
0.000
0.069
- . - - -
X
16:05:47
0.013
0.0810
- . - - - -
0.000
0.073
- . - - -
X
16:06:47
0.013
0.0820
- . - - - -
0.000
0.076
- . - - -
X
16:07:47
0.013
0.0820
- . - - - -
0.000
0.076
- . - - -
X
16:08:47
0.014
0.0840
- . - - - -
0.000
0.077
- . - - -
X
16:09:47
0.013
0.0820
- . - - - -
0.000
0.077
- . - - -
X
16:10:47
0.014
0.0840
- . - - - -
0.000
0.079
- . - - -
X
16:11:47
0.013
0.0810
- . - - - -
0.000
0.079
- . - - -
X
16:12:47
0.014
0.0860
- . - - - -
0.000
0.079
- . - - -
X
16:13:47
0.014
0.0840
- . - - - -
0.000
0.079
- . - - -
X
16:14:47
0.014
0.0850
- . - - - -
0.000
0.081
- . - - -
X
16:15:47
0.014
0.0830
- . - - - -
0.000
0.081
- . - - -
X
16:16:47
0.014
0.0850
- . - - - -
0.000
0.081
- . - - -
X
16:17:47
0.013
0.0830
- . - - - -
0.000
0.082
- . - - -
X
16:18:47
0.013
0.0820
- . - - - -
0.000
0.082
- . - - -
X
16:19:47
0.014
0.0850
- . - - - -
0.000
0.082
- . - - -
X
16:20:47
0.014
0.0840
- . - - - -
0.000
0.083
- . - - -
X
16:21:47
0.014
0.0840
- . - - - -
0.000
0.083
- . - - -
X
16:22:47
0.014
0.0850
- . - - - -
0.000
0.083
- . - - -
X
Plt: 0.079245
Evaluated: PST <= 0.4 dmax < 20% dmax1
FLICKER: Source test PASS!
Gepr üft mit EMC tes t s oftware V2.3f / PAS5000 von Spi tzenber ger + Spies GmbH & Co. KG, Schmidstr 32-34, D-94234 Vi ec htac h, 14.04.2005
File
No.
F25715-01-00BA
, page 20 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
5.5
Immunity requirements - S2
For test instruments and accessories used see section 6 Part S 2.
5.5.1
Description of the test location
Test location:
AV1
5.5.2
Photo documentation of the test set-up
5.5.3 Test
result
MODE TERMINAL
CHANNEL
MONITORING
CHECK
S/N
RESULT
LINE CH1
CH1 left
left
Speaker CH1
Sound
91
DATA !
LINE CH2
CH2 left
left
Speaker CH2
Sound
96
> 6 dB o.L.
LINE CH3
CH3 left
left
Speaker CH3
Sound
82
> 6 dB o.L.
LINE CH4
CH4 left
left
Speaker CH4
Sound
79
> 6 dB o.L.
LINE CH5
CH5 left
left
Speaker CH5
Sound
79
> 6 dB o.L.
LINE CH6
CH6 left
left
Speaker CH6
Sound
73
DATA !
LINE CH7
CH7 left
left
Speaker CH7
Sound
75
DATA !
LINE CH1
LINE CH1
left
Speaker CH1
Sound
88
> 6 dB o.L.
LINE CH2
LINE CH2
left
Speaker CH2
Sound
89
> 6 dB o.L.
LINE CH3
LINE CH3
left
Speaker CH3
Sound
80
> 6 dB o.L.
LINE CH4
LINE CH4
left
Speaker CH4
Sound
79
> 6 dB o.L.
LINE CH5
LINE CH5
left
Speaker CH5
Sound
77
> 6 dB o.L.
LINE CH6
LINE CH6
left
Speaker CH6
Sound
72
> 6 dB o.L.
LINE CH7
LINE CH7
left
Speaker CH7
Sound
74
> 6 dB o.L.
LINE
MAINS
left
Speaker CH1
Sound
71
> 6 dB o.L.
LINE
MAINS
left
Speaker CH3
Sound
73
> 6 dB o.L.
LINE
MAINS
left
Speaker CH5
Sound
73
> 6 dB o.L.
LINE
MAINS
left
Speaker CH7
Sound
73
> 6 dB o.L.
The requirements are FULFILLED.
File
No.
F25715-01-00BA
, page 21 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
5.6
Immunity requirements - S3
For test instruments and accessories used see section 6 Part S 3.
5.6.1
Description of the test location
Test location:
AV1
5.6.2
Photo documentation of the test set-up
5.6.3 Test
result
MODE CHANNEL
MONITORING
CHECK
S/N
RESULT
LINE left
Speaker
CH1
Sound
96
DATA
!
LINE left
Speaker
CH2
Sound
94
DATA
!
LINE left
Speaker
CH3
Sound
88
DATA
!
LINE left
Speaker
CH4
Sound
87
DATA
!
LINE left
Speaker
CH5
Sound
90
DATA
!
LINE left
Speaker
CH6
Sound
92
DATA
!
LINE left
Speaker
CH7
Sound
74
DATA
!
The requirements are FULFILLED.
Remarks:
For detailed results, please see the attachment.
File
No.
F25715-01-00BA
, page 22 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
5.7
Electrostatic discharge
For test instruments and accessories used see section 6 Part I 2.
5.7.1
Description of the test location
Test location:
Shielded Room S3
5.7.2
Photo documentation of the test set-up
5.7.3
Legend C: Contact discharge A: Air discharge
C
A