JBL AVA 7 (serv.man2) EMC - CB Certificate ▷ View online
File
No.
F25715-01-00BA
, page 23 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
Test specification:
Contact discharge voltage:
2 kV
/
4 kV
Air discharge voltage:
2 kV
/
4 kV
/
8 kV
Discharge impedance:
330
Ω / 150 pF
Discharge factor:
≥ 1 sec.
Number of discharges:
≥ 10
Type of discharge:
Direct discharge:
- Air discharge
- Contact discharge
Indirect discharge:
- Contact discharge
Polarity:
- negative
- positive
Discharge location:
- all external locations accessible by hand
- horizontal plate (HCP)
- horizontal plate (HCP)
- vertical coupling plate (VCP)
- see photo documentation of the test set-up
- horizontal plate (HCP)
- horizontal plate (HCP)
- vertical coupling plate (VCP)
- see photo documentation of the test set-up
5.7.4 Test
result
The requirements are FULFILLED.
Performance Criterion:
B
Remarks:
During electrostatic discharge sine wave was disturbed.
File
No.
F25715-01-00BA
, page 24 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
5.8 Radiated,
radio-frequency, electromagnetic field
For test instruments and accessories used see section 6 Part I 3.
5.8.1
Description of the test location
Test location:
Anechoic Chamber A2
5.8.2
Photo documentation of the test set-up
5.8.3 Test
specification:
Frequency range:
900 MHz Pulse modulation
Field strength: 3
V/m
EuT - antenna distance: 3
m
Modulation:
PM / square wave: 217 Hz / duty cycle: 12.5 %
Antenna polarisation: -
vertical
5.8.4 Test
result
The requirements are FULFILLED.
Performance Criterion:
A
Remarks:
During the test no deviation was detected to the selected operation mode(s).
File
No.
F25715-01-00BA
, page 25 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
5.9
Electrical fast transients / Burst
For test instruments and accessories used see section 6 Part I 4.
5.9.1
Description of the test location
Test location:
Shielded Room S3
5.9.2
Photo documentation of the test set-up
5.9.3 Test
specification:
Coupling network: 1
kV
Burst frequency: 5.0
kHz
Coupling duration:
≥ 60 sec.
Polarity:
- negative
- positive
File
No.
F25715-01-00BA
, page 26 of 28
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.4
5.9.4 Coupling
points
Cable description:
AC power line
Screening:
Status:
Signal transmission:
unscreened
active
analogue
active
analogue
Length: 1.0
m
5.9.5 Test
result
The requirements are FULFILLED.
Performance Criterion:
B
Remarks:
During fast transients the sine wave was disturbed.
Click on the first or last page to see other AVA 7 (serv.man2) service manuals if exist.