6   U S E D   T E S T   E Q U I P M E N T   A N D   A C C E S S O R I E S  
 
All test instruments used, in addition to the test accessories, are calibrated and verified regularly. 
 
 
  Test ID 
Model / Type 
Kind of Equipment 
Manufacturer 
Equipment No. 
 
  A4 
ESH 2 - Z 5 
LISN 
Rohde & Schwarz GmbH & Co  04-07/60-03-078 
 
ESH 3 - Z 2 
Pulse Limiter 
Rohde & Schwarz GmbH & Co  04-07/60-03-079 
 
N2000N 
RF Cable 
Huber + Suhner 
04-07/60-04-004 
 
N4000BNC 
RF Cable 
Huber + Suhner 
04-07/60-04-005 
 
ESHS 30 
Test Receiver 
Rohde & Schwarz GmbH & Co  04-07/63-04-002 
 
  A7 
RG 223/U 
RF Cable 5 m 
Huber + Suhner 
04-07/60-02-036 
 
MDS-21 
Absorbing Clamp 
Schwarzbeck  Mess-Elektronik  04-07/60-95-291 
 
ESCS-30 
Test Receiver 
Rohde & Schwarz GmbH & Co  04-07/63-03-001 
 
  H & Fl. 
PAS 10000 
4-Quadrant-Amplifier 
Spitzenberger + Spies GmbH & 04-07/68-03-002 
 
ARS 16/3 
Analyzer Reference Syst 
Spitzenberger + Spies GmbH & 04-07/74-03-004 
 
  I2 
THL-313 
Thermo-Hygrometer 
PTL Dr. Grabenhorst GmbH 
04-07/53-03-001 
 
NSG 435 
ESD Generator 
Schaffner Elektrotest GmbH 
04-07/75-04-001 
 
  I3 
URV 5 
RF Voltmeter 
Rohde & Schwarz GmbH & Co  04-07/31-02-001 
 
LMV-1817 
Noise Meter 
Leader 
04-07/31-86-025 
 
N-800-N 
RF Cable 
MBPS GmbH 
04-07/60-04-064 
 
N-1000-N 
RF Cable 
MBPS GmbH 
04-07/60-04-071 
 
N-1000-N 
RF Cable 
MBPS GmbH 
04-07/60-04-072 
 
N-1000-N 
RF Cable 
MBPS GmbH 
04-07/60-04-075 
 
N-1500-N 
RF Cable 
MBPS GmbH 
04-07/60-04-076 
 
URV 5 - Z 2 
RF Probe 10 V 
Rohde & Schwarz GmbH & Co  04-07/60-96-402 
 
URV 5 - Z 2 
RF Probe 10 V 
Rohde & Schwarz GmbH & Co  04-07/60-96-403 
 
7/12 
A2 Rosenberger 
Rosenberger HF-Technik 
04-07/60-96-405 
 
3 m 
Antenna Cable 
Rosenberger HF-Technik 
04-07/60-96-406 
 
HFRM - 301 
RF Relais Matrix 
SBF electronic 
04-07/60-98-003 
 
50 Ohm / 10 dB 
Attenuator 
Huber + Suhner 
04-07/60-98-025 
 
CBL 6140 A 
Bilog Antenna 
Schaffner Elektrotest GmbH 
04-07/62-02-002 
 
SMT 03 
Signal Generator 
Rohde & Schwarz GmbH & Co  04-07/64-01-005 
 
BLWA 2050-500 
RF Amplifier 
Bonn Elektronik GmbH 
04-07/66-93-245 
 
  I4 
NSG 2025 
Burst Generator 
Schaffner Elektrotest GmbH 
04-07/75-03-005 
 
  S2 
NRVS 
Power Meter 
Rohde & Schwarz GmbH & Co  04-07/32-97-084 
 
CS 10 V 
Oscilloscope 
Voltcraft 
04-07/38-04-001 
 
STT 400 
Isol. Transformer 
BÜRKLIN 
04-07/55-03-004 
 
6 dB / 25 W 
RF Attenuator 
Huber + Suhner 
04-07/60-03-061 
 
Switchingbox 
Switching Box 
MBPS GmbH 
04-07/60-04-026 
 
RCo 8 Ohm 
RC Network 
Fiedler Meßtechnik 
04-07/60-04-029 
 
RCi 47 kOhm 
RC Network 
Fiedler Meßtechnik 
04-07/60-04-033 
 
MSF 
Mains Filter 
Fiedler Meßtechnik 
04-07/60-04-041 
 
Type 1481 
RF Filter 
MBPS GmbH 
04-07/60-04-043 
 
URV 5 - Z 4 
100 V - Insertion Unit 
Rohde & Schwarz GmbH & Co  04-07/60-04-232 
 
50 Ohm / 6 Watt 
Terminator 
Huber + Suhner 
04-07/60-98-023 
 
SML 01 
Signal Generator 
Rohde & Schwarz GmbH & Co  04-07/64-03-009 
 
6000 N 
RF Amplifier 
PMM 
04-07/66-03-008 
 
UPA 
Audio Analyser 
Rohde & Schwarz GmbH & Co  04-07/74-03-002 
 
 
 
 
 File 
No. 
F25715-01-00BA
, page 28 of 28 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.4 
 
 
  Test ID 
Model / Type 
Kind of Equipment 
Manufacturer 
Equipment No. 
 
 
  S3 
URV 35 
RF Voltmeter 
Rohde & Schwarz GmbH & Co  04-07/31-03-001 
 
NRVS 
Power Meter 
Rohde & Schwarz GmbH & Co  04-07/32-97-083 
 
CS 10 V 
Oscilloscope 
Voltcraft 
04-07/38-03-001 
 
ETR 
Isol. Transformer 
Trafo-Technik Hoppecke Gmb  04-07/55-04-001 
 
Type 1481 
RF Filter 
MBPS GmbH 
04-07/60-03-028 
 
0,5 - 3 kHz 
Bandpass 
Fiedler Meßtechnik 
04-07/60-03-029 
 
BN 754601 
Switch 
Spinner GmbH 
04-07/60-04-021 
 
LBS 
Band-Stop-Filter 
Fiedler Meßtechnik 
04-07/60-04-022 
 
Mains Stop Filter S3 
Mains Stop Filter S3 
Fiedler Meßtechnik 
04-07/60-04-024 
 
URV 5 - Z 4 
100 V - Insertion Unit 
Rohde & Schwarz GmbH & Co  04-07/60-04-232 
 
SML 01 
Signal Generator 
Rohde & Schwarz GmbH & Co  04-07/64-03-005 
 
6000 N 
RF Amplifier 
PMM 
04-07/66-03-009 
 
UPA 
Audio Analyser 
Rohde & Schwarz GmbH & Co  04-07/74-03-002 
 
Open Strip Line 
Open Strip Line 
SBF electronic 
04-07/92-03-001 
 
 
 
 
 
 
 
Immunity conducted voltages (S2)
Manufa./Impo.  :  Harman Consumer
Model  :  AVA-7
E.U.T  :  Power-Amplifier
Serial-No.  :  0001
________________________________________________________________________________________
Report No.  :  F25715
Attachment Page 1 of 25
[dB(µV)]
90
100
110
120
130
140
 0,15 
[MHz]
20
40
60
80
100
120
140
 150 
Test point (injection into) :  CH1 left
Mode of EUT : LINE CH1
Criterion : Sound
Ref.-S/N : 91 dB
Monitoring : Speaker CH1
Output : 53 mW/8 Ohm
Channel : left
Margin : 6 dB
 
Test Engineer : M. Hackl
Date : 24.02.2005
Place : Immunity Site 2
 
 
Frequency       Level           Limit      Margin 
  [MHz]       [dB(µV)]      [dB(µV)]     [dB] 
94,0
125,0
120,0
5,0
95,0
125,0
120,0
5,0
96,0
125,0
120,0
5,0
97,0
125,0
120,0
5,0
98,0
125,0
120,0
5,0
99,0
125,0
120,0
5,0
100,0
124,0
120,0
4,0
101,0
123,0
119,0
4,0
102,0
123,0
119,0
4,0
103,0
124,0
119,0
5,0
104,0
123,0
119,0
4,0
105,0
122,0
118,0
4,0
106,0
123,0
118,0
5,0
110,0
122,0
117,0
5,0
 
Immunity conducted voltages (S2)
Manufa./Impo.  :  Harman Consumer
Model  :  AVA-7
E.U.T  :  Power-Amplifier
Serial-No.  :  0001
________________________________________________________________________________________
Report No.  :  F25715
Attachment Page 2 of 25
[dB(µV)]
90
100
110
120
130
140
 0,15 
[MHz]
20
40
60
80
100
120
140
 150 
Test point (injection into) :  CH2 left
Mode of EUT : LINE CH2
Criterion : Sound
Ref.-S/N : 96 dB
Monitoring : Speaker CH2
Output : 53 mW/8 Ohm
Channel : left
Margin : 6 dB
 
Test Engineer : M. Hackl
Date : 24.02.2005
Place : Immunity Site 2
 
 
Page of 55