JBL ARRAY EMC - CB Certificate ▷ View online
page 2 of 32
Ref. No.: 515845
TRF No.: I60065__C
Test item
Description ........................................ : Powered Subwoofer
Trademark......................................... :
Model and/or type reference ............. : 1500 Array/230
Manufacturer ..................................... : HARMAN CONSUMER GROUP
Rating(s)............................................ : AC 220-240V , 50-60Hz, 1000W, Class
ΙΙ
Test case verdicts
Test case does not apply to the test object..................: N/A (Not Applicable)
Test item does meet the requirement ..........................: P (Pass)
Test item does not meet the requirement ....................: F (Fail)
Testing
Date of receipt of test item ..........................................: 3 October 2005
Date(s) of performance of test .....................................: 18 October – 10 November 2004
General remarks
“This report is not valid as a CB Test Report unless appended to a CB Test Certificate issued by a NCB, in
accordance with IECEE 02”.
accordance with IECEE 02”.
This test report shall not be reproduced except in full without the written approval of the testing laboratory.
The test results presented in this report relate only to the item tested.
“(see remark #)” refers to a remark appended to the report.
“(see appended table)” refers to a table appended to the report.
Throughout this report a point is used as the decimal separator.
page 3 of 32
Ref. No.: 515845
TRF No.: I60065__C
Copy of marking plate
page 4 of 32
Ref. No.: 515845
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
3 GENERAL
REQUIREMENTS
Safety class of the apparatus ................................ : Class II
P
4
GENERAL CONDITIONS OF TESTS
4.1.4
Ventilation instructions require the use of the test
box
box
No, not for this product.
N/A
5 MARKING
Comprehensible and easily discernible
P
Permanent durability against water and petroleum
spirit
spirit
P
5.1
Identification, maker, model .................................. :
, 1500 Array/230
P
Class
ΙΙ symbol
P
Rated supply voltage and symbol ......................... : 220-240V , 50-60Hz
P
Rated current or power consumption .................... : (1000W)
N/A
5.2 Earth
terminal
N/A
Hazardous live terminals
N/A
Supply output terminals (other than mains)
N/A
5.3
Use of triangle with exclamation mark
N/A
5.4
Instructions for use
5.4.1
Mains powered equipment not exposed to dripping
or splashing
or splashing
P
Hazardous live terminals, instructions for wiring
N/A
Instructions for replacing lithium battery
N/A
Explanation of marking of the manually operated
mechanical switch (MOMS)
mechanical switch (MOMS)
N/A
5.4.2
Instructions for permanently connected equipment
N/A
6 HAZARDOUS
RADIATION
6.1
Ionizing radiation
≤ 36 pA/kg (0.5 mR/h)
N/A
6.2
Laser radiation, emission limits to IEC 60825 ....... :
N/A
Emission limits under fault conditions
N/A
page 5 of 32
Ref. No.: 515845
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
7
HEATING UNDER NORMAL OPERATING CONDITIONS (See appended table)
7.1
Temperature rises not exceeding specified values,
no operation of fuse links
no operation of fuse links
P
7.1.1
Temperature rise of accessible parts
P
7.1.2
Temperature rise of parts providing electrical
insulation
insulation
P
7.1.3
Temperature rise of parts acting as a support or as
a mechanical barrier
a mechanical barrier
P
7.1.4
Temperature rise of windings
P
7.1.5
Parts not subject to a limit under 7.1.1 to 7.1.4
P
7.2
Softening temperature of insulating material
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
supporting parts conductively connected to the
mains carrying a current > 0.2 A at least 150 ºC
See list of critical component
P
8
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION
AGAINST ELECTRIC SHOCK
AGAINST ELECTRIC SHOCK
8.1
Conductive parts covered by lacquer, paper,
untreated textile oxide films and beads etc.
considered to be bare
untreated textile oxide films and beads etc.
considered to be bare
PCB P
8.2
No shock hazard when changing voltage setting
device, fuse-links or handling drawers etc.
device, fuse-links or handling drawers etc.
N/A
8.3
Insulation of hazardous live parts not provided by
hygroscopic material
hygroscopic material
Not used
P
8.4
No risk of electric shock following the removal of a
cover which can be removed by hand
cover which can be removed by hand
P
8.5
Class
Ι equipment
Basic insulation between hazardous live parts and
earthed accessible parts
earthed accessible parts
N/A
Capacitors bridging basic insulation complying with
14.2.1a
14.2.1a
N/A
Basic insulation bridged by components complying
with 14.3.4.3
with 14.3.4.3
N/A
Class
ΙΙ equipment and Class ΙΙ constructions within Class Ι equipment
8.6
Reinforced or double insulation between
hazardous live parts and accessible parts
hazardous live parts and accessible parts
P
Components bridging reinforced or double
insulation complying with 14.1 a) or 14.3
insulation complying with 14.1 a) or 14.3
Mains transformer
P
Basic and supplementary insulation each being
bridged by a capacitor complying with 14.2.1 a)
bridged by a capacitor complying with 14.2.1 a)
N/A