page 22 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.06 times rated voltage  ...........: 220-240 
 
 
Ambient temperature (
°C) ......................................: 22 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC) ..................................: 22 
 
 
Ambient temperature t2 (ºC) ..................................: 22 
 
No.  Component 
No. 
Fault 
Test voltage 
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
100% 
output 
 
 
254.4 2.5h F1 4.2 
Pin = 760W Iin = 4.2A Uout = 78V  
After 25 min. the amplifier switch 
of and then on after 5 more min. 
The test was interrupted after 2.5 
h. when temperatures was stable. 
No high temperature. 
BR400 
-
 - 
+
 
sc 
254.4 / 198 
F1 
F1 opened immediately. OK 
BR400 
 - 
 
sc 
254.4 / 198 
F1 
F1 opened immediately. OK 
C407 sc  254.4  1min 
 F1  - 
Normal 
conditions 
C421 
sc 
254.4 / 198 
F1 
F1 opened immediately. OK
 
C402 sc 
254.4 
5min F1  - 
Relay R1 turns on and off  OK
 
C415 
sc 
254.4 
- F1 - 
Turns off immediately.Q406 and 
D402 broke down. OK 
Speaker 
sc 
254.4 
- F1 - 
Several components broke down. 
OK 
 
 
 
page 23 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
14 
TABLE: list of critical components and materials 
Object/part No. 
Manufacturer/ 
trademark 
Type/model 
Technical data 
Standard 
Mark(s) of 
conformity 
Transformer  
Keen Ocean 
Ind. 
TTO-14459-00 
230V 50Hz 
IEC 60065 
Tested in the 
appliance 
with thermal link 
Seki Controls 
Co., Ltd. 
ST-22 
105°C 5A  230V
IEC 60691 
VDE 
Disconnectable 
crimp, terminal    
housing 
Chyao Shiunn 
              
JS-2430BS-2H   
JS-2430A-06 
94V-2 
IEC 60065 
Tested in the 
appliance 
Mains fuse F1 
Conquer 
Electronics 
UTE 
T3.5AL  250V 
IEC 60127 
VDE 
Appliance  inlet 
Chily 
3516 
10A 250V 
IEC 60320 
VDE 
Cordset 
Plug 
Cord 
connector 
Dongguan Well 
Shin 
 
 
WS-019 
H05VV-F 
WS-002E 
 
16A 125V 
2x1mm² 
10A 125V 
IEC 60799 
 
IEC 61058-1 
 
Mains switch 
Rong Feng 
RF-1003 
10(4)A  250V, 
8/80A 
IEC 60065 
Annex G.1.1 
NEMKO 
Mains capacitor, 
across the line. 
CXAC1 and 
CXAC2 
UTX HQX 
0.22
µF 275V 
X2 
IEC 60384-14 
2:nd edition 
 
Alt. mains 
capacitor, 
across the line. 
CXAC1 and 
CXAC2 
TEAPO XG-VS 
0.22
µF 275V 
X2 
IEC 60384-14 
2:nd edition 
 
Line filter 
L13 
Elytone 
Electronic 
YT-10778 342µH IEC 
60065 
Annex G.1.3 
Tested in the 
appliance 
Line filter 
L17 
Elytone 
Electronic 
YT-13192 155µH IEC 
60065 
Annex G.1.3 
Tested in the 
appliance 
 
 
page 24 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
Object/part No. 
Manufacturer/ 
trademark 
Type/model 
Technical data 
Standard 
Mark(s) of 
conformity 
Tube over L17 
(plastic material) 
Sumitomo ELY0411 Rated 
VW-1 
Complies 
with 
IEC 60707:1981 
FV 1 
Tested in the 
appliance 
PCB Goodwell 
various 
94V-0 
Complies 
with 
IEC 60707:1981 
FV 1 
Tested in the 
appliance 
 
 
 
page 25 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
 
 GROUP DIFFERENCES (COMMON MODIFICATIONS) TO IEC 60065   
 
 
CONTENTS 
Add the following annexes: 
Annex ZB (normative) Special national conditions 
Annex ZC (informative) A-deviations 
 P 
1.1.1 
Replace the text of note 1 by: 
NOTE 1  This standard can be used as a guide for 
the testing of battery operated apparatus. 
 P 
3.1 Delete 
the 
note. 
Add the following indent: 
Exposure to excessive sound pressures from 
headphones or earphones  
NOTE  A new method is under consideration by 
CENELEC/TC 206 
 P 
15.1.1 
Delete notes 1 and 2. 
Add to note 4: 
Attention is drawn to the fact that a standard is 
under preparation (presently prEN 50074) for 
socket-outlets which allow connection of Class II 
appliances only. 
 P 
15.2 
Delete note 2. 
 
16.1 
Delete note 1. 
 
16.2 Delete 
the 
note. 
 
20 
Delete note 2. 
 
Annex B 
Delete note 2. 
 
B.5.4.1e) 
Delete notes 1 and 2. 
 
B.8.1 
Delete notes 1, 2 and 3. 
 
B.8.2 Delete 
the 
note. 
 
B.14.12 
Delete notes 1 and 2. 
 
Annex G 
Delete the note. 
 
 
Page of 47