JBL ARRAY EMC - CB Certificate ▷ View online
page 22 of 32
Ref. No.: 515845
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0.9 or 1.06 times rated voltage ...........: 220-240
Ambient temperature (
°C) ......................................: 22
Winding temperature rise measurements
Ambient temperature t1 (ºC) ..................................: 22
Ambient temperature t2 (ºC) ..................................: 22
No. Component
No.
Fault
Test voltage
(V)
Test
time
Fuse No.
Fuse
current
(A)
Result
1
-
100%
output
254.4 2.5h F1 4.2
Pin = 760W Iin = 4.2A Uout = 78V
After 25 min. the amplifier switch
of and then on after 5 more min.
The test was interrupted after 2.5
h. when temperatures was stable.
No high temperature.
of and then on after 5 more min.
The test was interrupted after 2.5
h. when temperatures was stable.
No high temperature.
2
BR400
-
-
+
sc
254.4 / 198
-
F1
-
F1 opened immediately. OK
2
BR400
-
sc
254.4 / 198
-
F1
-
F1 opened immediately. OK
3
C407 sc 254.4 1min
F1 -
Normal
conditions
4
C421
sc
254.4 / 198
-
F1
-
F1 opened immediately. OK
5
C402 sc
254.4
5min F1 -
Relay R1 turns on and off OK
6
C415
sc
254.4
- F1 -
Turns off immediately.Q406 and
D402 broke down. OK
D402 broke down. OK
7
Speaker
sc
254.4
- F1 -
Several components broke down.
OK
OK
page 23 of 32
Ref. No.: 515845
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14
TABLE: list of critical components and materials
P
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Transformer
Keen Ocean
Ind.
TTO-14459-00
230V 50Hz
IEC 60065
Tested in the
appliance
with thermal link
Seki Controls
Co., Ltd.
ST-22
105°C 5A 230V
IEC 60691
VDE
Disconnectable
crimp, terminal
housing
Chyao Shiunn
JS-2430BS-2H
JS-2430A-06
94V-2
IEC 60065
Tested in the
appliance
Mains fuse F1
Conquer
Electronics
UTE
T3.5AL 250V
IEC 60127
VDE
Appliance inlet
Chily
3516
10A 250V
IEC 60320
VDE
Cordset
Plug
Cord
connector
Dongguan Well
Shin
WS-019
H05VV-F
WS-002E
16A 125V
2x1mm²
10A 125V
IEC 60799
IEC 61058-1
Mains switch
Rong Feng
RF-1003
10(4)A 250V,
8/80A
IEC 60065
Annex G.1.1
NEMKO
Mains capacitor,
across the line.
CXAC1 and
CXAC2
UTX HQX
0.22
µF 275V
X2
IEC 60384-14
2:nd edition
Alt. mains
capacitor,
across the line.
CXAC1 and
CXAC2
TEAPO XG-VS
0.22
µF 275V
X2
IEC 60384-14
2:nd edition
Line filter
L13
Elytone
Electronic
YT-10778 342µH IEC
60065
Annex G.1.3
Tested in the
appliance
Line filter
L17
Elytone
Electronic
YT-13192 155µH IEC
60065
Annex G.1.3
Tested in the
appliance
page 24 of 32
Ref. No.: 515845
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Tube over L17
(plastic material)
Sumitomo ELY0411 Rated
VW-1
Complies
with
IEC 60707:1981
FV 1
Tested in the
appliance
PCB Goodwell
various
94V-0
Complies
with
IEC 60707:1981
FV 1
Tested in the
appliance
page 25 of 32
Ref. No.: 515845
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
GROUP DIFFERENCES (COMMON MODIFICATIONS) TO IEC 60065
CONTENTS
Add the following annexes:
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations
P
1.1.1
Replace the text of note 1 by:
NOTE 1 This standard can be used as a guide for
the testing of battery operated apparatus.
the testing of battery operated apparatus.
P
3.1 Delete
the
note.
Add the following indent:
-
Exposure to excessive sound pressures from
headphones or earphones
headphones or earphones
NOTE A new method is under consideration by
CENELEC/TC 206
CENELEC/TC 206
P
15.1.1
Delete notes 1 and 2.
Add to note 4:
Attention is drawn to the fact that a standard is
under preparation (presently prEN 50074) for
socket-outlets which allow connection of Class II
appliances only.
under preparation (presently prEN 50074) for
socket-outlets which allow connection of Class II
appliances only.
P
15.2
Delete note 2.
P
16.1
Delete note 1.
P
16.2 Delete
the
note.
P
20
Delete note 2.
P
Annex B
Delete note 2.
P
B.5.4.1e)
Delete notes 1 and 2.
P
B.8.1
Delete notes 1, 2 and 3.
P
B.8.2 Delete
the
note.
P
B.14.12
Delete notes 1 and 2.
P
Annex G
Delete the note.
P
Click on the first or last page to see other ARRAY service manuals if exist.