DOWNLOAD JBL ARRAY Service Manual ↓ Size: 3.04 MB | Pages: 47 in PDF or view online for FREE

Model
ARRAY
Pages
47
Size
3.04 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
array.pdf
Date

JBL ARRAY EMC - CB Certificate ▷ View online

 
 
page 30 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
 
 
National differences  KOREA 
IEC 60065:1998 
 
CB Bulletin 107A / KR 04 I 
 
 
5.101 Addition 
Other marking; 
Wording “            “ ( See the CB Bulletine) or an 
information regulated in IEC Publication 60417 
giving high voltage warning to layman shall be 
marked, if an apparatus contains a part more 
than 600 volts. 
 N/A 
15.1.1 
Plugs for the connection of the apparatus to the 
supply mains and socket outlets for providing 
mains power to other apparatus shall comply with 
the Korean requirements (KSC 8300 and 8305). 
10-16A IEC approved plug 
accepted. 
31 
Radio frequency Interference 
The apparatus shall comply with the relevant 
CISPR requirements. (EMC=EMI + EMS) 
Not checked 
N/A 
 
 
 
page 31 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
National differences  SINGAPORE   
(These differences are taken from IEC 60065:1993 and adopted to IEC 60065:1998)
 
 
 
IEC 60065: 1998 
Clauses:  4, 7, 9, 10 and 16.                                                                                                             
 
 
IEC 60065 
Cl. 
Requirement - Test 
Result - Remark 
Verdict 
 
 
Throughout the standard, whenever the words "white pine board" appear, insert  
the words "or plywood board" to it. 
 
SS143 Amendment No. 1 and No. 2 
 
4.1.3 
(4.1.3)* 
Delete "45 % to 75 %" and insert 65 ± 5 %. 
75% maximum in IEC 60065: 
1998 
7.1 
(7.1) 
Resistance to heat without external forces. 
Adopt the temperature specified for the tropical 
conditions. 
 P 
8.6 
(9.3.4) 
Delete the note " A Quality Assessment System 
for capacitors complying with Subclause 14.2 is 
under consideration in the IEC". 
This is not in IEC 60065:1998. 
10.2 
(10.2) 
Humidity treatment 
Adopt the testing conditions designed for tropical 
conditions. 
120 h at a relative humidity of 
93% 
16 
(16) 
External flexible cords 
Delete "IEC Publication 60227: Polyvinyl Chloride 
Insulated Cables of Rated Voltages up to and 
Including 450/750 V and IEC publication 60245: 
Rubber insulated Cables of rated up to and 
including 450/750 V " and insert "Singapore 
Standard 236: Flexible Cords", whenever they 
appear in this clause. 
Delete "CEE Publication 13, CEE Publication 2 
and IEC Publication 60173: Colours of the Cores 
of Flexible Cables and Cords" whenever they 
appear in this clause. 
 P 
16.2 
(16.2) 
Delete the notes in small print and insert  "A 
nominal cross-sectional area of  0.75 mm² will 
satisfy this requirement". 
This is not in IEC 60065:1998. 
 
* in parenthesis: clauses acc. to IEC 60065:1993 
 
 
 
page 32 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
16.3b 
(16.4b) 
 
Delete “Subclause 3.1 of IEC Publication 60227-
2: Part 2: Test Methods“ and insert “Subclause 
9.1 of SS 236“: 
9.1 Flexing test (except for tinsel cords, twisted 
twin and single core cords). The test shall be 
carried out  by means of the apparatus shown in 
Figure 5. This apparatus has a carrier C 
supporting two pulleys A and B arranged so that 
the cord is horizontal between the pulleys. The 
carrier moves backward and forward over a 
distance of 1 m at an approximately constant 
speed of 0.33 m/s.                                                 
A sample of flexible cord about 5 m long shall be 
stretched over the pulleys as shown in the figure, 
each end being loaded with a weight. The weight 
and the diameter of the pulleys A and B shall be 
given in  
The pulleys shall have a semi-circular shaped 
groove for circular cords and a flat groove for 
parallel twin cords. The restraining clamps D shall 
be fixed so that the pull is always applied by the 
weight from which the carrier is moving away. 
The carrier shall make 30 000 backward and 
forward movements (60 000 single strokes). Each 
conductor of the sample shall be loaded with the 
current specified in Table 2.                                
For twin cords and for light PVC-sheated 3-core 
cords, the voltage between the conductors shall 
be approximately 230 V a.c. For all other cords 
having three or more cores a three-phase a.c. 
voltage of about 400 V shall be applied to three 
conductors, any additional conductors being 
connected to the neutral.                                
During the test no open-circuit in any core or 
short-circuit between cores shall occur.                   
After the test, any sheath on cords having three 
or more cores shall be removed. The cord, or the 
laid up cores, shall then withstand the voltage test 
specified in Subclause 8.2 or 8.3 as appropriate, 
but with a test voltage not exceeding 2000 V. 
TABLE 1, TABLE 2, FIGURES 4 and  5, see the   
CB BULLETIN 
 P 
 
Page of 47
Display

Click on the first or last page to see other ARRAY service manuals if exist.