JBL ARRAY EMC - CB Certificate ▷ View online

 
 
page 10 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
14 COMPONENTS 
 
14.1 
Resistors 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
 N/A 
 
a) Resistors separately approved ......................... :  
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
b) Resistors separately approved ......................... :  
N/A 
14.2 
Capacitors and RC units 
 
Capacitors separately approved 
Yes  
14.2.1 
Y capacitors tested to IEC 60384-14, 2:nd Edition :  
N/A 
14.2.2 
X capacitors tested to IEC 60384-14, 2:nd Edition : CXAC1 and CXAC2 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ..................... :
 N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm
3
 
where short-circuit current exceeds 0.2 A: 
compliance with IEC 60384-1, 4.38 category B or 
better ..................................................................... :
 N/A 
 
Capacitors with volume exceeding 1750 mm
3
mounted closer to a potential ignition source than 
Table 5 permits: compliance with IEC 60384-1, 
4.38 category B or better ....................................... :
 N/A 
 
Shielded by a barrier to FV 0 or metal  .................. :  
N/A 
14.3 
Inductors and windings 
14.3.1 
Transformers and inductors marked with 
manufacturer’s name and type  ............................. :
Keen Ocean 
TTO-14459-00 
 
Transformers and inductors separately approved  : No 
N/A 
14.3.2 
Isolating transformer complies with 14.3.3, 
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
 P 
 
Separating transformer complies with 14.3.3, 
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
 N/A 
 
Flammability test of insulating material acc. To 
20.1.4 (except in thin sheet form) 
 N/A 
14.3.3.1 
Clearances and creepage distances according to 
clause 13 
 P 
14.3.3.2 
Transformers meet the constructional 
requirements 
 P 
 
 
page 11 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
14.3.4.1 
Class 
ΙΙ transformers have adequate separation 
between hazardous live windings and accessible 
windings (double or reinforced insulation) 
Prim-sec: 
>10mm 
 
Coil formers and partition walls 
≥ 0.4 mm 
Min. three layers thin sheet 
insulation. 
14.3.4.2 
Class 
Ι transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
 N/A 
14.3.4.3 
Separating transformers with at least basic insulation 
 N/A 
14.3.5.1 
Class 
ΙΙ transformers have adequate insulation 
between hazardous live windings and accessible 
parts (double or reinforced insulation) 
Mains transformer          
(internal iron core) 
 
Coil formers and partition walls 
≥ 0.4 mm 
  
14.3.5.2 
Class 
Ι transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
 N/A 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 N/A 
 
Component meets category FV 1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 N/A 
 
 
page 12 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
14.5 
Protective devices 
 
Protective devices used within their ratings 
 
 
External clearance and creepage distances 
appropriate for the voltage across the device when 
opened 
 P 
14.5.1.1 
a) Thermal cut-outs separately approved 
 
N/A 
 
b) Thermal cut-outs tested as part of the submission 
 N/A 
14.5.1.2 
a) Thermal links separately approved 
 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices resettable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 60127 
 P 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : F1 T3.15AL,  250V 
14.5.2.3 
Not possible to connect fuses in parallel ............... :  
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ........ :
Tools are required 
14.5.3 
PTC-S thermistors comply with IEC 60738 
 
N/A 
 
PTC-S devices (15 W) category FV 1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 N/A 
 
 
page 13 of 32 
Ref. No.: 515845  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
14.6 
Switches 
     (See appended table) 
14.6.1 Permanently 
connected 
equipment 
provided 
with 
an all-pole mains switch unless 5.4.2 is met 
 N/A 
14.6.2 
Manually operated mechanical switch (MOMS), 
required where power consumption > 15 W and/or 
peak voltage > 4 kV; MOMS required ................... :
Yes  
 
Switch readily accessible and not in mains cord 
On the rear panel 
(Accepted for this product group)
 
 Exception 
for 
automatic 
switching 
 
N/A 
 
Exception for continuous operation 
 
N/A 
14.6.3 
Manually operated mechanical switch (MOMS): 
switch indication On position clearly discernible 
I, On 
 
Indication by marking meets Cl. 5 
 
 
Indication of the OFF position 
O, Off 
14.6.4 
Manually operated mechanical switch (MOMS) 
fitted, is there a Stand-by mode  ............................ :
 N/A 
 
Stand-by mode clearly discernible ........................ :  
N/A 
 
Exception for low Stand-by current < 0.7 mA 
(peak) 
 N/A 
14.6.5 
Components bridging contacts of mains switches 
comply with 14.1 a) or 14.2.2 
 N/A 
14.6.6 
Manually operated mechanical switches (MOMS) 
separately approved to IEC 61058-1 
Current consumption: 0.9A 
Peak surge current 
(measured): 47A 
 
Manually operated mechanical switch (MOMS) 
tested as part of the equipment complies with 
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8 
and/or 14.6.9 and Annex G (G1.1) 
 N/A 
14.7 
Safety interlocks 
 
Safety interlocks to 2.8 of IEC 60950 
 
N/A 
14.8 
Voltage setting devices 
 
Voltage setting device not likely to be changed 
accidentally 
 N/A 
14.9 
Motors 
14.9.1 
Endurance test on motors 
 
N/A 
 Motor 
start 
test 
 
N/A 
 Dielectric 
strength 
test 
 
N/A 
14.9.2 
Not adversely affected by oil or grease etc. 
 
N/A 
14.9.3 
Protection against moving parts 
 
N/A 