JBL ARRAY EMC - CB Certificate ▷ View online
page 10 of 32
Ref. No.: 515845
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14 COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N/A
a) Resistors separately approved ......................... :
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
b) Resistors separately approved ......................... :
N/A
14.2
Capacitors and RC units
Capacitors separately approved
Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2:nd Edition :
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2:nd Edition : CXAC1 and CXAC2
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
N/A
14.2.5
Capacitors with volume exceeding 1750 mm
3
where short-circuit current exceeds 0.2 A:
compliance with IEC 60384-1, 4.38 category B or
better ..................................................................... :
compliance with IEC 60384-1, 4.38 category B or
better ..................................................................... :
N/A
Capacitors with volume exceeding 1750 mm
3
,
mounted closer to a potential ignition source than
Table 5 permits: compliance with IEC 60384-1,
4.38 category B or better ....................................... :
Table 5 permits: compliance with IEC 60384-1,
4.38 category B or better ....................................... :
N/A
Shielded by a barrier to FV 0 or metal .................. :
N/A
14.3
Inductors and windings
14.3.1
Transformers and inductors marked with
manufacturer’s name and type ............................. :
manufacturer’s name and type ............................. :
Keen Ocean
TTO-14459-00
TTO-14459-00
P
Transformers and inductors separately approved : No
N/A
14.3.2
Isolating transformer complies with 14.3.3,
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
P
Separating transformer complies with 14.3.3,
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
N/A
Flammability test of insulating material acc. To
20.1.4 (except in thin sheet form)
20.1.4 (except in thin sheet form)
N/A
14.3.3.1
Clearances and creepage distances according to
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
page 11 of 32
Ref. No.: 515845
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.3.4.1
Class
ΙΙ transformers have adequate separation
between hazardous live windings and accessible
windings (double or reinforced insulation)
windings (double or reinforced insulation)
Prim-sec:
>10mm
P
Coil formers and partition walls
≥ 0.4 mm
Min. three layers thin sheet
insulation.
insulation.
P
14.3.4.2
Class
Ι transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic insulation
N/A
14.3.5.1
Class
ΙΙ transformers have adequate insulation
between hazardous live windings and accessible
parts (double or reinforced insulation)
parts (double or reinforced insulation)
Mains transformer
(internal iron core)
(internal iron core)
P
Coil formers and partition walls
≥ 0.4 mm
N
14.3.5.2
Class
Ι transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category FV 1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
page 12 of 32
Ref. No.: 515845
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.5
Protective devices
Protective devices used within their ratings
P
External clearance and creepage distances
appropriate for the voltage across the device when
opened
appropriate for the voltage across the device when
opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices resettable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC 60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : F1 T3.15AL, 250V
P
14.5.2.3
Not possible to connect fuses in parallel ............... :
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ........ :
replacing fuse-links without the use of a tool ........ :
Tools are required
P
14.5.3
PTC-S thermistors comply with IEC 60738
N/A
PTC-S devices (15 W) category FV 1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
N/A
page 13 of 32
Ref. No.: 515845
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.6
Switches
(See appended table)
14.6.1 Permanently
connected
equipment
provided
with
an all-pole mains switch unless 5.4.2 is met
N/A
14.6.2
Manually operated mechanical switch (MOMS),
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
Yes
P
Switch readily accessible and not in mains cord
On the rear panel
(Accepted for this product group)
P
Exception
for
automatic
switching
N/A
Exception for continuous operation
N/A
14.6.3
Manually operated mechanical switch (MOMS):
switch indication On position clearly discernible
switch indication On position clearly discernible
I, On
P
Indication by marking meets Cl. 5
P
Indication of the OFF position
O, Off
P
14.6.4
Manually operated mechanical switch (MOMS)
fitted, is there a Stand-by mode ............................ :
fitted, is there a Stand-by mode ............................ :
N/A
Stand-by mode clearly discernible ........................ :
N/A
Exception for low Stand-by current < 0.7 mA
(peak)
(peak)
N/A
14.6.5
Components bridging contacts of mains switches
comply with 14.1 a) or 14.2.2
comply with 14.1 a) or 14.2.2
N/A
14.6.6
Manually operated mechanical switches (MOMS)
separately approved to IEC 61058-1
separately approved to IEC 61058-1
Current consumption: 0.9A
Peak surge current
(measured): 47A
Peak surge current
(measured): 47A
P
Manually operated mechanical switch (MOMS)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
N/A
14.7
Safety interlocks
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9
Motors
14.9.1
Endurance test on motors
N/A
Motor
start
test
N/A
Dielectric
strength
test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A