Harman Kardon SoundSticks II EMC - CB Certificate ▷ View online
Page 66 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
IEC 60695-11-20
1999
Part 11-20: Test flames – 500 W flame
test methods
test methods
EN 60695-
11-20
11-20
1999
IEC 60730-1
(mod)
(mod)
1999
Automatic electrical controls for
household and similar use
household and similar use
− Part 1:
General requirements
EN 60730-1
2000
IEC 60825-1
1993
Safety of Laser products
− Part 1:
Equipment classification, requirements
and use guide
and use guide
EN 60825-1
+ corr.
February
+ A11
+corr. July
+ corr.
February
+ A11
+corr. July
1994
1995
1995
1996
1997
1997
IEC 60825-2
2000
Part 2: Safety of optical fibre
communication systems
communication systems
EN 60825-2
2000
IEC 60825-9
1999
Part 9: Compilation of maximum
permissible exposure to incoherent
optical radition
permissible exposure to incoherent
optical radition
IEC 60851-3
1996
Winding wires
− Test methods − Part 3:
Mechanical properties
EN 60851-3
1996
IEC 60851-5
1996
Winding wires
− Test methods − Part 5:
Electrical properties
EN 60851-5
1996
IEC 60851-6
1996
Methods of test for winding wires
− Part
6: Thermal properties
EN 60851-6
1996
IEC 60885-1
1987
Electrical test methods for electric cables
− Part 1: Electrical tests for cables, cords
and wires up to and including 450/750V
− Part 1: Electrical tests for cables, cords
and wires up to and including 450/750V
IEC 60990
1999
Methods of measurement of touch
current and protective conductor current
current and protective conductor current
EN 60990
1990
IEC 61058-1
1996
Switches for appliances
− Part 1:
General requirements
IEC 61965
2000
Mechanical safety of cathode ray tubes
EN 61965
2001
ISO 178
1993
Plastics – Determination of flexural
properties
properties
EN ISO 178
1996
ISO 179
Series
Plastics – Determination of Charpy
impact Strength
impact Strength
EN ISO 179
Series
ISO 180
1993
Plastics – Determination of Izod impact
strength
strength
EN ISO 180
2000
ISO 261
1998
ISO general purpose metric screw
threads
threads
− General plan
ISO 262
1998
ISO general purpose metric screw
threads
threads
− Selected sizes for screws,
bolts and nuts
ISO 527
Series
Plastics – Determination of tensile
properties
properties
EN ISO 527
Series
ISO 3864
1984
Safety colours and safety signs
(cont.)
ISO 4892
Series
Plastics – Methods of exposure to
laboratory light sources
laboratory light sources
EN ISO 4892
Series
P
Page 67 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
ISO 7000
1989
Graphical symbols for use on equipment
− Index and synopsis
− Index and synopsis
ISO 8256
1990
Plastics – Determination of tensile-
impact strength
impact strength
EN ISO 8256
1996
ISO
1994
9772 Cellular plastics – Determination of
horizontal burning charactericstics of
small specimens subjected to a small
flame
horizontal burning charactericstics of
small specimens subjected to a small
flame
ISO 9773
1998
Plastics – Determination of burning
behviour of thin flexible vertical
specimens in contact with a samll-flame
ignition source
behviour of thin flexible vertical
specimens in contact with a samll-flame
ignition source
EN ISO 9773
1998
ITU-T
Recommend-
ation K.17
Recommend-
ation K.17
1988
Tests on power-fed repeaters using
solid-state devices in order to check
the arrangements for protection
from external interference.
solid-state devices in order to check
the arrangements for protection
from external interference.
ITU-T
Recommend-
ation K.21
Recommend-
ation K.21
1996
Resistibility of subscribers’ terminals
to overvoltages and overcurrents.
to overvoltages and overcurrents.
(cont.)
1) The HD 21 series is related to, but not directly equivalent with the IEC 60227 series.
2) The HD 22 series is related to, but not directly equivalent with the IEC 60245 series.
3) IEC 60364-4-41:1992 is superseded by IEC 60364-4-41:2001.
4) EN 132400, Sectional Specification: Fixed capacitors for electromagnetic interference suppression
and connection to the supply mains (Assessment level D), and its amendments are related to, but not
directly equivalent to IEC 60384-14.
2) The HD 22 series is related to, but not directly equivalent with the IEC 60245 series.
3) IEC 60364-4-41:1992 is superseded by IEC 60364-4-41:2001.
4) EN 132400, Sectional Specification: Fixed capacitors for electromagnetic interference suppression
and connection to the supply mains (Assessment level D), and its amendments are related to, but not
directly equivalent to IEC 60384-14.
P
Page 68 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
National Differences Australia (AU)
IEC 60950-1, 1st ed.
Annex ZZ
(normative)
Variations to IEC 60950-1:2001 for application in Australia
and New Zealand
and New Zealand
P
ZZ1 Introduction
This Annex sets out variations between this Standard and IEC
60950-1:2001. These variations indicate national variations for
purposes of the IECEE CB Scheme and will be published in
the IECEE CB Bulletin. These variations are indicated within
the body of the Standard.
60950-1:2001. These variations indicate national variations for
purposes of the IECEE CB Scheme and will be published in
the IECEE CB Bulletin. These variations are indicated within
the body of the Standard.
P
ZZ.2 Variations
The variations are as follows:
CLAUSE
P
1.2
Between the definitions for ‘Person, service’ and
‘Range, rated frequency’ insert the following:
‘Range, rated frequency’ insert the following:
l ignition source 1.2.12.201
P
1.2.12.15
After the definition of 1.2.12.15, add the following:
1.2.12.201 potential ignition source: Possible fault
which can start a fire if the open-circuit voltage
measured across an interruption or faulty contact
exceeds a value of 50 V (peak) a.c. or d.c. and
the product of the peak value of this voltage and
the measured r.m.s current under normal
operating conditions exceeds 15 VA.
which can start a fire if the open-circuit voltage
measured across an interruption or faulty contact
exceeds a value of 50 V (peak) a.c. or d.c. and
the product of the peak value of this voltage and
the measured r.m.s current under normal
operating conditions exceeds 15 VA.
Such a faulty contact or interruption in an
electrical connection includes those which may
occur in conductive patterns on printed boards.
electrical connection includes those which may
occur in conductive patterns on printed boards.
NOTE 201 An electronic protection circuit may be
used to prevent such a fault from becoming a
POTENTIAL IGNITION SOURCE.
used to prevent such a fault from becoming a
POTENTIAL IGNITION SOURCE.
NOTE 202 This definition is from AS/NZS
60065:2003.
60065:2003.
P
1.5.1
Add the following to the end of first paragraph: ‘or
the relevant Australian/New Zealand Standard’.
the relevant Australian/New Zealand Standard’.
P
Page 69 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
1.5.2
Add the following to the end of first and third dash
items:
items:
‘or the relevant Australian/New Zealand
Standard’.
Standard’.
P
2.1 Delete
the
Note.
P
3.2.3 Delete
Note
2.
N/A
3.2.5.1
Modify Table 3B as follows:
Delete the first four rows and replace with
Minimum conductor sizes
RATED CURRENT OF
EQUIPMENT
A
Nominal cross-
section area
mm
2
AWG or Kcmil
(cross-section
area in mm
2
)
See note 1
Over 0.2 up to and including 3
Over 3 up to and including 7.5
Over 7.5 up to and including 10
Over 10 up to and including 16
0,5
1)
0,75
(0,75)
2)
1,00
(1,0 )
3)
1,5
18 [0,8]
16 [1,3]
16 [1,3]
14 [2]
Replace footnote 1) with the following:
1) This nominal cross-sectional area is only
allowed for Class II appliances if the length of the
power supply cord, measured between the point
where the cord, or cord guard, enters the
appliance, and the entry to the plug does not
exceed 2 m (0.5 mm
allowed for Class II appliances if the length of the
power supply cord, measured between the point
where the cord, or cord guard, enters the
appliance, and the entry to the plug does not
exceed 2 m (0.5 mm
2
three-core supply flexible
cords are not permitted; see AS/NZS 3191).
Delete Note 1.
N/A
4.3.6
Replace paragraph three with:
Equipment with a plug portion, suitable for
insertion into a 10 A 3-pin flat-pin socket-outlet
complying with AS/NZS 3112, shall comply with
the requirements in AS/NZS 3112 for equipment
with integral pins for insertion into socket-outlets.
insertion into a 10 A 3-pin flat-pin socket-outlet
complying with AS/NZS 3112, shall comply with
the requirements in AS/NZS 3112 for equipment
with integral pins for insertion into socket-outlets.
The EUT is not direct plug-in
equipment
equipment
N/A
4.3.13.5
Add the following to the end of the first
paragraph:
paragraph:
‘, or AS/NZS 2211.1’.“.
P
4.7
Add the following paragraph:
For alternative tests refer to Clause 4.7.201.
N/A
4.7.201
Add the following after Clause 4.7.3.6.
4.7.201 Resistance to fire – Alternative tests
N/A
Click on the first or last page to see other SoundSticks II service manuals if exist.