ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
2.6.3.3
When subject to impedance testing, protective
earthing and bonding are required to be
subjected to the additional test conditions
specified.
earthing and bonding are required to be
subjected to the additional test conditions
specified.
Class II equipment
N/A
3.2.1.2
Equipment connected to a centralized d.c. power
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instructions requirements.
system, and having one pole of the DC mains
input terminal connected to the main protective
earthing terminal in the equipment, is required to
comply with special earthing, wiring, marking and
installation instructions requirements.
N/A
4.2.8.1
Enclosures around CRTs with a face diameter of
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
160 mm or more are required to reduce the risk of
injury due to the implosion of the CRT.
No such devices within the EUT
N/A
4.3.2
Equipment with handles is required to comply
with special loading tests.
with special loading tests.
No such devices within the EUT
N/A
5.1.8.3
Equipment intended to receive
telecommunication ringing signals is required to
comply with a special touch current measurement
tests.
telecommunication ringing signals is required to
comply with a special touch current measurement
tests.
No TNV circuit within the EUT
N/A
6.2.1
Enamel coating on winding wire not considered
electrical separation unless subjected to special
investigation.
electrical separation unless subjected to special
investigation.
N/A
6.4
Equipment intended for connection to
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
telecommunication network outside plant cable is
required to be protected against overvoltage from
power line crosses in accordance with 6.4 and
Annex NAC.
N/A
6.5
Equipment connected to a telecommunications
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
network and supplied with an earphone intended
to be held against, or in the ear is required to
comply with special acoustic pressure tests.
N/A
M.2
Continuous ringing signals up to 16 mA only are
permitted if the equipment is subjected to special
installation and performance restrictions.
permitted if the equipment is subjected to special
installation and performance restrictions.
No TNV circuit within the EUT
N/A
Page 83 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
National Differences China (CN)
IEC 60950, 3rd ed.
1. Supply tolerance
Item 1.4.5 of IEC 60950 stipulates the tolerance
of rated voltage is +6 % and –10 %, while
GB4943-2001 makes a specification of tolerance
of +10 % and –10 %.
of rated voltage is +6 % and –10 %, while
GB4943-2001 makes a specification of tolerance
of +10 % and –10 %.
P
2. Power rating marking
Item 1.7.1 of IEC 60950 does not specify
concrete figures of markings of supply voltage
and frequency, instead, descriptions are given by
examples. But the examples do not include
China’s mains voltage. GB4943-2001 stipulates
that:
concrete figures of markings of supply voltage
and frequency, instead, descriptions are given by
examples. But the examples do not include
China’s mains voltage. GB4943-2001 stipulates
that:
-
A single rated voltage shall expressed as 220
V
V
-
When a rated voltage range is given, the
range shall cover 220 V
range shall cover 220 V
-
When a variety voltages or rated voltage
ranges are given, one of them shall be set as
220 V when dispatched from the factory
ranges are given, one of them shall be set as
220 V when dispatched from the factory
-
Rated frequency or rated frequency range
shall be 50 Hz or include 50 Hz
shall be 50 Hz or include 50 Hz
-
If a unit is not provided with means of direct
connection to the AC mains supply, it need
not be marked with any electrical rating
connection to the AC mains supply, it need
not be marked with any electrical rating
P
3. Plate and warning marking in Chinese
Item 1.7.12 of GB4943-2001 stipulates:
instructions and equipment markings related to
safety shall be in standardized Chinese.
instructions and equipment markings related to
safety shall be in standardized Chinese.
P
4. Power supply plug
According to China’s particular standard for
power supply plug, it is added in article 3.2.1 of
GB4943-2001 that plug connecting equipment
with AC mains supply shall be in accordance with
requirements of GB1002.
power supply plug, it is added in article 3.2.1 of
GB4943-2001 that plug connecting equipment
with AC mains supply shall be in accordance with
requirements of GB1002.
N/A
Page 84 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
National Differences Korea (KR)
IEC 60950-1, 1st ed.
1.5.101 Addition
Plugs for the connection of the apparatus to the
supply mains shall comply with the Korean
requirement (KSC 8305 and 8305).
supply mains shall comply with the Korean
requirement (KSC 8305 and 8305).
N/A
7 Addition
EMC
The apparatus shall comply with the relevant
CISPR standards.
CISPR standards.
P
Page 85 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
National Differences United States of America (US)
IEC 60950-1, 1st ed.
The United States of America and Canada have
adopted a single, bi–national standard,
CAN/CSA-C22.2 No. 60950-1/UL 60950-1, First
Edition, which is based on IEC 60950-1, First
Edition. This bi–national standard should be
consulted for further details on the national
conditions and differences summarized below.
adopted a single, bi–national standard,
CAN/CSA-C22.2 No. 60950-1/UL 60950-1, First
Edition, which is based on IEC 60950-1, First
Edition. This bi–national standard should be
consulted for further details on the national
conditions and differences summarized below.
P
SPECICAL NATIONAL CONDITIONS
The following is a summary of the key national
differences based on national regulatory
requirements, such as the National Electrical
Code (NEC), ANSI/NFPA 70-2002, which are
referenced in legislation and which from the basis
for the rules and practices followed in electrical
and building installations.
differences based on national regulatory
requirements, such as the National Electrical
Code (NEC), ANSI/NFPA 70-2002, which are
referenced in legislation and which from the basis
for the rules and practices followed in electrical
and building installations.
P
Sub-Clause National Condition
1.1.1
All equipment is to be designed to allow
installation in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70, the
Canadian Electrical Code (CEC), Part I,
CAN/CSA-C22.1, and when applicable, the
National Electrical Safety Code, IEEE C2. Also,
unless marked or otherwise identified, installation
is allowed per the Standard for the Protection of
Electronic Computer/Data-Processing Equipment,
ANSI/NFPA 75.
installation in accordance with the National
Electrical Code (NEC), ANSI/NFPA 70, the
Canadian Electrical Code (CEC), Part I,
CAN/CSA-C22.1, and when applicable, the
National Electrical Safety Code, IEEE C2. Also,
unless marked or otherwise identified, installation
is allowed per the Standard for the Protection of
Electronic Computer/Data-Processing Equipment,
ANSI/NFPA 75.
P
1.4.14
For Pluggable Equipment Type A, the protection
in the installation is assumed to be 20 A.
in the installation is assumed to be 20 A.
P