DOWNLOAD Harman Kardon SoundSticks II Service Manual ↓ Size: 3.58 MB | Pages: 105 in PDF or view online for FREE

Model
SoundSticks II
Pages
105
Size
3.58 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
soundsticks-ii.pdf
Date

Harman Kardon SoundSticks II EMC - CB Certificate ▷ View online

 
 
 
 
Page 46 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
5.2 
TABLE: electric strength tests, impulse tests and voltage surge tests 
test voltage applied between: 
test voltage (V) 
a.c. / d.c. 
breakdown 
 Yes / No 
RI: L/N and secondary circuits  
4242 Vdc 
No 
RI: L/N and plastic enclosure covered with metal foil 
3000 Vac 
No 
RI: Transformer: primary and secondary 
3000 Vac 
No 
RI: Transformer: secondary and core 
3) 
3000 Vac 
No 
RI: Insulating tape around the outer side of transformer (T1)  
3000 Vac 
No 
FI: Line and Neutral after current fuse (F1) opened 
1500 Vac 
No 
supplementary information 
Note: 
1)  FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation. 
2)  Test voltage a.c. / d.c. 
3)  The core of transformer (T1) is considered as primary winding. 
 
 
 
 
 
Page 47 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
5.3 
TABLE: fault condition tests 
 
ambient temperature (
°C) .................................... : 25 
 
 
model/type of power supply  ................................ : See page 1 
 
 
manufacturer of power supply ............................. : See page 1 
 
 
rated markings of power supply  .......................... : See page 1 
 
No. 
component  
No. 
fault 
test vol-
tage 
 (V) 
test time 
fuse
No. 
fuse current 
(A) 
result 
Tested on model NU40-2240050-I3 
U2, pin 1-2 
264 
1 hour 
F1 
0.364 
Observation: Normal operation. 
No hazards. 
Damaged: 
 
Temp: 61.5 ºC 
Max. Voltage: 
24.29 Vdc
 
U2, pin 1 
264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
C6, ZD1, U1. 
Temp: 
 
Max. Voltage: 
 
U2, pin 3-4 
264 
10 min. 
F1 
0.044 
Observation: Unit shut down. 
No hazards. 
Damaged: 
 
Temp: 
 
Max. Voltage: 
 
U2, pin 4 
264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
U1, R22, C4. 
Temp: 
 
Max. Voltage: 
 
5 BD1  S 
264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
 
Temp: 
 
Max. Voltage: 
 
6 C1  S 
264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
 
Temp: 
 
Max. Voltage: 
 
7 Q1 
(D-S)  S  264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
U1, R21. 
Temp: 
 
Max. Voltage: 
 
8 Q1 
(D-G)  S  264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
U1, R21. 
Temp: 
 
Max. Voltage: 
 
U1, pin 7-8 
264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
U1. 
Temp: 
 
Max. Voltage: 
 
10 D1  S 
264 
hour 
F1 0.364 
Observation: Normal operation. 
No hazards. 
Damaged: 
 
Temp: 61.5 ºC 
Max. Voltage: 
24.31 Vdc
 
 
 
 
 
Page 48 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
5.3 (cont.)  TABLE: fault condition tests 
 
ambient temperature (
°C) ....................................: 25 
 
 
model/type of power supply .................................: See page 1 
 
 
manufacturer of power supply  .............................: See page 1 
 
 
rated markings of power supply  ..........................: See page 1 
 
No. 
component  
No. 
fault 
test vol-
tage 
 (V) 
test time 
fuse
No. 
fuse current 
(A) 
result 
11 R21  S 264 1 
hour 
F1 0.043 
Observation: Normal operation. 
No hazards. 
Damaged: 
 
Temp: 61.5 ºC 
Max. Voltage: 
24.35 Vdc
 
12 ZD1  S 264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
C6, U1, R18, R19. 
Temp: 
 
Max. Voltage: 
 
13 Output  O/L 264 
Steady 
state 
F1 0.5 
Total testing duration: 6.5 
hours.  
Damaged: 
 
Temp: 105 ºC 
Max. Voltage: 
24.0 Vdc
 
14 T1 
secondary  O/L 
264 
Steady 
state 
F1 0.512 
Total testing duration: 6 hours. 
Damaged: 
 
Temp: 107 ºC 
Max. Voltage: 
24.0 Vdc
 
15 Output  S  264 10 
min. F1  0.107 
Observation: Unit shut down. 
No hazards. 
Damaged: 
 
Temp: 
 
Max. Voltage: 
 
16  T1 secondary 
264 
10 min. 
F1 
0.328 
Observation: Unit shut down. 
No hazards. 
Damaged: 
 
Temp: 
 
Max. Voltage: 
 
Tested on model NU40-2100400-I3 
17 
U2, pin 1-2 
264 
1 hour 
F1 
0.408 
Observation: Normal operation. 
No hazards. 
Damaged: 
 
Temp: 91.9 ºC 
Max. Voltage: 
10.29 Vdc
 
18 
U2, pin 1 
264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
R18, R19, R21. 
Temp: 
 
Max. Voltage: 
 
19 
U2, pin 3-4 
264 
1 hour 
F1 
0.406 
Observation: Normal operation. 
No hazards. 
Damaged: 
 
Temp: 91.9 ºC 
Max. Voltage: 
10.3 Vdc
 
20 
U2, pin 4 
264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
R18, R19, R21. 
Temp: 
 
Max. Voltage: 
 
 
 
 
 
Page 49 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
5.3 (cont.)  TABLE: fault condition tests 
 
ambient temperature (
°C) ....................................: 25 
 
 
model/type of power supply .................................: See page 1 
 
 
manufacturer of power supply  .............................: See page 1 
 
 
rated markings of power supply  ..........................: See page 1 
 
No. 
component  
No. 
fault 
test vol-
tage 
 (V) 
test time 
fuse
No. 
fuse current 
(A) 
result 
21 BD1  S 264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
 
Temp: 
 
Max. Voltage: 
 
22 C1  S 264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
 
Temp: 
 
Max. Voltage: 
 
23 Q1 
(D-S)  S  264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
U1, R21. 
Temp: 
 
Max. Voltage: 
 
24 Q1 
(D-G)  S 
264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
U1, R21. 
Temp: 
 
Max. Voltage: 
 
25 
U1, pin 7-8 
264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
U1. 
Temp: 
 
Max. Voltage: 
 
26 D1  S 264 1 
hour 
F1 0.364 
Observation: Normal operation. 
No hazards. 
Damaged: 
 
Temp: 61.5 ºC 
Max. Voltage: 
24.31 Vdc
 
27 R21  S 264 1 
hour 
F1 0.043 
Observation: Normal operation. 
No hazards. 
Damaged: 
 
Temp: 61.5 ºC 
Max. Voltage: 
24.35 Vdc
 
28 ZD1  S 264 
< 1 s 
F1 
> 5 
Observation: F1 opened. 
Damaged: 
C6, U1, R18, R19. 
Temp: 
 
Max. Voltage: 
 
29 Output  O/L 264 
Steady 
state 
F1 0.472 
Total testing duration: 6 hours. 
Damaged: 
 
Temp: 91 ºC 
Max. Voltage: 
9.5 Vdc
 
30 T1 
secondary  O/L 
264 
Steady 
state 
F1 0.476 
Total testing duration: 5.5 
hours.  
Damaged: 
 
Temp: 95 ºC 
Max. Voltage: 
9.5 Vdc
 
Page of 105
Display