Document
EMC - CB Certificate
Brand
Device
Audio
File
soundsticks-ii.pdf
Date

Harman Kardon SoundSticks II EMC - CB Certificate ▷ View online

 
 
 
 
Page 38 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
1.6.2 
TABLE: electrical data (in normal conditions) 
fuse # 
Irated 
(A) 
U (V) 
P (W) 
I (mA) 
Ifuse 
(mA) 
condition/status 
Tested on model NU40-2100400-I3 
F1 
— 
90 V (50 / 60 Hz) 
48.7 / 48.7
920 / 940 920 / 940 Maximum rated output load 
F1 
1.2 
100 V (50 / 60 Hz) 
48.0 / 48.0
842 / 866 842 / 866 Maximum rated output load 
F1 
1.2 
240 V (50 / 60 Hz) 
46.9 / 46.9
461 / 451 461 / 451 Maximum rated output load 
F1 
— 
254.4 V (50 / 60 Hz)  46.9 / 46.9
440 / 431 440 / 431 Maximum rated output load 
F1 
— 
264 V (50 / 60 Hz) 
46.9 / 46.9
426 / 417 426 / 417 Maximum rated output load 
Tested on model NU40-2240050-I3 
F1 
— 
90 V (50 / 60 Hz) 
10.0 / 10.0
321 / 317 321 / 317 Maximum rated output load 
F1 
1.2 
100 V (50 / 60 Hz) 
10.1 / 10.1
261 / 291 261 / 291 Maximum rated output load 
F1 
1.2 
240 V (50 / 60 Hz) 
18.1 / 17.8
161 / 161 161 / 161 Maximum rated output load 
F1 
— 
254.4 V (50 / 60 Hz)  17.8 / 17.6
156 / 156 156 / 156 Maximum rated output load 
F1 
— 
264 V (50 / 60 Hz) 
17.6 / 17.6
152 / 153 152 / 153 Maximum rated output load 
Tested on model NU40-2050400-I3 
F1 
— 
90 V (50 / 60 Hz) 
22.7 / 22.7
533 / 550 533 / 550 Maximum rated output load 
F1 
1.2 
100 V (50 / 60 Hz) 
22.6 / 22.6
511 / 508 511 / 508 Maximum rated output load 
F1 
1.2 
240 V (50 / 60 Hz) 
22.3 / 22.3
258 / 252 258 / 252 Maximum rated output load 
F1 
— 
254.4 V (50 / 60 Hz)  22.3 / 22.3
244 / 240 244 / 240 Maximum rated output load 
F1 
— 
264 V (50 / 60 Hz) 
22.3 / 22.3
237 / 233 237 / 233 Maximum rated output load 
 
 
 
 
Page 39 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
2.1.1.5 
TABLE: energy hazards measurements 
Measured 
between 
Max. V (Uoc)  Max. A (Isc)
V of Max. 
power 
A of Max. 
power 
Max. power 
Bridged by 
test finger 
Tested on model NU40-2100400-I3 
Output  
10.31 Vdc 
5.24 A 
9.13 Vdc 
4.4 A 
40.17 VA 
No 
Tested on model NU40-2240050-I3 
Output  
24.41 Vdc 
3.3 A 
23.83 Vdc 
2.4 A 
57.19 VA 
No 
Tested on model NU40-2050400-I3 
Output  
5.2 Vdc 
6.9 A 
4.58 Vdc 
4.7 A 
21.52 VA 
No 
 
 
 
 
Page 40 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
2.10.3 and 
2.10.4 
TABLE: clearance and creepage distance measurements 
clearance cl and creepage 
distance dcr at/of: 
Up 
(V) 
U r.m.s. 
 (V) 
required cl
 (mm) 
cl 
 (mm) 
required 
 dcr (mm) 
dcr 
(mm) 
On PCB solder side: 
Line and Neutral before 
current fuse (F1) (FI) 
340 
240  1.5  3.1 2.5 3.1 
Two ends of the current fuse 
(F1) (FI) 
340 
240  1.5  4.5 2.5 4.5 
Primary and secondary (two 
sides of CY3) (RI) 
340 
240  4.0  6.5 5.0 6.5 
Primary and secondary (two 
sides of U2) (RI) 
340 
240  4.0  6.0 5.0 6.0 
Primary traces and secondary 
heatsink (RI) 
340 
240  4.0  9.6 5.0 9.6 
On PCB component side: 
Line and Neutral before 
current fuse (F1) (FI) 
340 
240  1.5  4.3 2.5 4.3 
Two ends of the current fuse 
(F1) (FI) 
340 
240  1.5  5.4 2.5 5.4 
Primary and secondary (two 
sides of CY3) (RI) 
340 
240  4.0  6.7 5.0 6.7 
Primary and secondary (two 
sides of U2) (RI) 
340 
240  4.0  6.2 5.0 6.2 
Primary component (D3) to 
secondary heatsink 
3)
 (RI) 
340 240  4.0  > 
10 
4) 
5.0 > 
10 
4) 
Primary component (U2) to 
secondary heatsink 
3)
 (RI) 
340 240  4.0  9.1 
4) 
5.0 9.1 
4) 
Primary components to user 
accessible parts 
3)
 (RI)
 
340 
240  4.0  8.0 5.0 8.0 
 
 
 
 
Page 41 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
2.10.3 and 
2.10.4 
(cont.) 
TABLE: clearance and creepage distance measurements 
clearance cl and creepage 
distance dcr at/of: 
Up 
(V) 
U r.m.s. 
 (V) 
required cl
 (mm) 
cl 
 (mm) 
required 
 dcr (mm) 
dcr 
(mm) 
Transformer (T1): 
Primary traces to secondary 
traces on PCB solder side 
(RI)
 
520 
249  4.4  8.7 5.0 8.7 
Primary winding to secondary 
winding (RI)
 
520 
249  4.4  6.5 5.0 6.5 
Secondary winding to core 
2) 
(RI) 
520 
249  4.4  7.0 5.0 7.0 
Secondary components
 3)
 
(D2) to core 
2)
 (RI) 
520 
249  4.4  8.5 5.0 8.5 
Note: 
1)  FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation. 
2)  The core of transformer (T1) is considered as primary winding, the TIW is used in secondary winding of 
transformer (T1). 
3)  A force of 10 N is applied to the internal components and 30 N is applied to the enclosure when 
measuring the distances. 
4)  Heatsink (HS1) is enclosed by two layers the insulating tape. 
 
.2.10.5 
TABLE: distance through insulation measurements 
distance through insulation di at/of: 
Up 
(V) 
test voltage 
 (V) 
required di 
 (mm) 
di 
(mm) 
Optocoupler (U2) (RI) 
340 
3000 Vac 
0.4 Min. 
0.4 
Enclosure (RI) 
340 
3000 Vac 
0.4 Min. 
2.0 
thin sheet material at/of: 
Up 
(V) 
test voltage 
(V) 
required 
layer(s) 
layer(s) 
 
Insulating tape around the outer side 
2)
 of 
transformer (T1) (RI) 
520 
3000 Vac / 
1 layer 
2 2 
Insulating tape around the shielding metal (RI) 
340 
3000 Vac / 
1 layer 
2 2 
Note: 
1)  FI: Functional insulation; BI: Basic insulation; SI: Supplementary insulation; RI: Reinforced insulation. 
2)  The core of transformer (T1) is considered as primary winding. 