DOWNLOAD Harman Kardon SoundSticks II Service Manual ↓ Size: 3.58 MB | Pages: 105 in PDF or view online for FREE

Model
SoundSticks II
Pages
105
Size
3.58 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
soundsticks-ii.pdf
Date

Harman Kardon SoundSticks II EMC - CB Certificate ▷ View online

 
 
 
 
Page 42 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
4.5 
TABLE: maximum temperatures 
 
test voltage (V) ................................:
90.0 254.4  264 
 
 
t
amb1 
(
°C) ..........................................:
32.7 41.5 41.1 
 
 
t
amb2 
(
°C) ..........................................:
41.5 41.1 39.6 
 
maximum temperature T of part/at:: 
T (
°C) 
allowed T
max
 (
°C)
Tested on model: NU40-2240050-I3 
Appliance inlet 
47.4 
49.1 
47.2 
70 
PCB under NTC1 
59.2 
59.9 
58.4 
130 (PCB) 
PCB under BD1 
59.9 
64.0 
58.4 
130 (PCB) 
L2 
56.9 61.0 62.5 120 
(130-10) 
CX1  
57.1 
62.8 
59.6 
100 
L1 
52.1 55.1 61.4 120 
(130-10) 
C1 58.8 
63.9 
62.5 
105 
PCB under Q1 
58.6 
70.0 
65.7 
130 (PCB) 
T1 coil 
61.8 
68.8 
67.5 
110 (120-10, B) 
T1 core  
60.1 
67.0 
65.7 
110 (120-10, B) 
CY3 59.9 
66.4 
65.0 
100 
PCB under U2 
59.8 
68.0 
63.9 
130 (PCB) 
PCB under D2 
59.6 
67.6 
63.3 
130 (PCB) 
Output cord / U3 
59.3 
67.7 
63.5 
105 
C5 / C4 
58.8 
67.4 
63.1 
105 
PCB under U1 
62.6 
68.1 
66.9 
130 (PCB) 
L3 
56.4 60.5 59.2 120 
(130-10) 
Enclosure inside near T1/ heatsink Q1 
54.9 
60.3 
59.2 
For stress relief 
test 
Enclosure outside near T1 
51.4 
55.4 
54.2 
95 (plastic) 
temperature T of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
T (
°C) 
allowed 
T
max
 (
°C) 
insulation 
class 
— 
— — — — — 
Note: 
Max. operation ambient is considered as 40 
°C which declared by the manufacturer. 
 
 
 
 
 
Page 43 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
4.5 (cont.)  TABLE: maximum temperatures 
 
test voltage (V) ................................:
90.0 254.4  264 
 
 
t
amb1 
(
°C) ..........................................:
39.8 39.7 40.7 
 
 
t
amb2 
(
°C) ..........................................:
39.7 40.7 41.5 
 
maximum temperature T of part/at:: 
T (
°C) 
allowed T
max
 (
°C)
Tested on model: NU40-2100400-I3 
Appliance inlet 
63.5 
57.4 
58.3 
70 
PCB under NTC1 
97.4 
77.9 
78.6 
130 (PCB) 
PCB under BD1 
105.6 
85.2 
85.7 
130 (PCB) 
L2 
98.0 80.3 81.2 120 
(130-10) 
CX1  
94.9 
82.6 
83.4 
100 
L1 
77.7 68.4 69.3 120 
(130-10) 
C1 101.8 
88.5 
89.4 
105 
PCB under Q1 
103.2 
89.7 
90.9 
130 (PCB) 
T1 coil 
106.4 
95.8 
96.9 
110 (120-10, B) 
T1 core  
102.7 
92.2 
93.2 
110 (120-10, B) 
CY3 96.1 
87.0 
88.1 
100 
PCB under U2 
100.1 
92.4 
93.4 
130 (PCB) 
PCB under D2 
102.5 
94.6 
95.5 
130 (PCB) 
Output cord / U3 
89.7 
84.3 
85.4 
105 
C5 / C4 
88.7 
83.1 
84.1 
105 
PCB under U1 
99.5 
88.1 
89.2 
130 (PCB) 
L3 
78.7 74.6 75.7 120 
(130-10) 
Enclosure inside near T1/ heatsink Q1 
90.3 
79.2 
80.3 
For stress relief 
test 
Enclosure outside near T1 
76.4 
68.7 
69.6 
95 (plastic) 
temperature T of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
T (
°C) 
allowed 
T
max
 (
°C) 
insulation 
class 
— 
— — — — — 
Note: 
Max. operation ambient is considered as 40 
°C which declared by the manufacturer. 
 
 
 
 
Page 44 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
4.5 (cont.)  TABLE: maximum temperatures 
 
test voltage (V) ................................:
90.0 254.4  264 
 
 
t
amb1 
(
°C) ..........................................:
40.2 40.6 41.1 
 
 
t
amb2 
(
°C) ..........................................:
40.6 41.1 40.2 
 
maximum temperature T of part/at:: 
T (
°C) 
allowed T
max
 (
°C)
Tested on model: NU40-2050400-I3 
Appliance inlet 
58.8 
57.2 
57.2 
70 
PCB under NTC1 
80.0 
69.0 
68.2 
130 (PCB) 
PCB under BD1 
78.3 
74.2 
74.4 
130 (PCB) 
L2 
75.6 71.8 71.9 120 
(130-10) 
CX1  
77.6 
75.8 
76.0 
100 
L1 
68.7 66.8 66.8 120 
(130-10) 
C1 83.6 
84.1 
81.6 
105 
PCB under Q1 
78.1 
80.2 
77.6 
130 (PCB) 
T1 coil 
83.3 
86.1 
83.4 
110 (120-10, B) 
T1 core  
79.8 
79.3 
79.6 
110 (120-10, B) 
CY3 76.2 
76.0 
76.2 
100 
PCB under U2 
91.7 
91.1 
91.2 
130 (PCB) 
PCB under D2 
93.1 
92.7 
92.8 
130 (PCB) 
Output cord / U3 
77.1 
77.2 
77.2 
105 
C5 / C4 
81.5 
81.2 
81.3 
105 
PCB under U1 
87.3 
85.8 
85.9 
130 (PCB) 
L3 
73.8 73.6 73.8 120 
(130-10) 
Enclosure inside near T1/ heatsink Q1 
69.8 
68.4 
68.6 
For stress relief 
test 
Enclosure outside near T1 
62.1 
61.0 
61.0 
95 (plastic) 
temperature T of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
T (
°C) 
allowed 
T
max
 (
°C) 
insulation 
class 
— 
— — — — — 
Note: 
Max. operation ambient is considered as 40 
°C which declared by the manufacturer. 
 
 
 
 
Page 45 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
4.5.2 
TABLE: ball pressure test of thermoplastic parts 
 allowed 
impression 
diameter (mm)  ..................... :
≤ 2 mm 
 
part 
test temperature 
(
°C) 
impression diameter 
(mm) 
Bobbin of T1 for material type CP-J-8800 
125 
1.1 
Bobbin of T1 for material type T375J 
125 
0.8 
Bobbin of T1 for material types PM-9820 / PM-9630 
125 
0.8 
PCB  
125 
0.9 
 
4.7 
TABLE: resistance to fire 
part 
manufacturer of material 
type of material 
thickness 
(mm) 
flammability
class 
Enclosure 
GE Plastics 
SE100X, SE1X, 
940(f1), 945(GG), 
N300, N300X 
Min. 2.0 mm   Min. V-1 
Alt. 
Bayer AG 
6485(f1), 6870 
Min. 2.0 mm   Min. V-1 
Bobbin of T1  
Hitachi Chemical 
CP-J-8800 
Min. 0.75 mm  V-0 
Alt. 
Chang Chun 
T375J 
Min. 0.75 mm  V-0 
Alt. 
Sumitomo Bakelite 
PM-9820, PM-9630
Min. 0.75 mm  V-0 
PCB 
various 
various 
Min. 1.5 mm 
Min. V-1 
 
Page of 105
Display