Harman Kardon SoundSticks II EMC - CB Certificate ▷ View online
Page 22 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
4.6.3
Doors or covers in fire enclosures
No such devices within the
EUT
EUT
N/A
4.6.4
Openings in transportable equipment
No openings at all
N/A
4.6.5
Adhesives for constructional purposes
No barriers or screen provided
to complying with the relevant
requirements of sub-clause
4.6.1, 4.6.2 or 4.6.4
to complying with the relevant
requirements of sub-clause
4.6.1, 4.6.2 or 4.6.4
N/A
Conditioning temperature (
°C)/time (weeks).......:
4.7
Resistance to fire
4.7.1
Reducing the risk of ignition and spread of flame
P
Method 1, selection and application of
components wiring and materials
components wiring and materials
(see appended table 4.7)
P
Method 2, application of all of simulated fault
condition tests
condition tests
N/A
4.7.2
Conditions for a fire enclosure
Fire enclosure is provided
P
4.7.2.1
Parts requiring a fire enclosure
P
4.7.2.2
Parts not requiring a fire enclosure
N/A
4.7.3 Materials
P
4.7.3.1 General
P
4.7.3.2
Materials for fire enclosures
(see appended table 1.5.1)
P
4.7.3.3 Materials
for
components and other parts outside
fire enclosures
N/A
4.7.3.4
Materials for components and other parts inside
fire enclosures
fire enclosures
(see appended table 1.5.1)
P
4.7.3.5
Materials for air filter assemblies
No such devices within the
EUT
EUT
N/A
4.7.3.6
Materials used in high-voltage components
No such devices within the
EUT
EUT
N/A
Page 23 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
5
ELECTRICAL REQUIREMENTS AND SIMULATED ABNORMAL CONDITIONS
5.1
Touch current and protective conductor current
5.1.1 General
P
5.1.2
Equipment under test (EUT)
P
5.1.3
Test circuit
Test circuit as in figure 5A is
used
used
P
5.1.4
Application of measuring instrument
Measuring instrument as in
annex D.1 is used
annex D.1 is used
P
5.1.5 Test
procedure
P
5.1.6 Test
measurements
P
Test
voltage (V) ..................................................:
Input voltage: 264 Vac, 60 Hz
Measured touch current (mA) ............................:
U2 / 500 = 0.165 mA
Max.
allowed
touch current (mA) .......................:
0.25 mA
Measured protective conductor current (mA) ....:
Max. allowed protective conductor current (mA) :
5.1.7
Equipment with touch current exceeding
3.5 mA ..............................................................:
3.5 mA ..............................................................:
No such equipments
N/A
5.1.8
Touch currents to and from telecommunication
networks and cable distribution systems and from
telecommunication networks
networks and cable distribution systems and from
telecommunication networks
No TNV circuit within the EUT
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network and a cable
distribution system
telecommunication network and a cable
distribution system
No TNV circuit within the EUT
N/A
Test
voltage (V) ..................................................:
Measured touch current (mA) ............................:
Max.
allowed
touch current (mA) .......................:
5.1.8.2
Summation of touch currents from
telecommunication networks.............................. :
telecommunication networks.............................. :
No TNV circuit within the EUT
N/A
5.2 Electric
strength
5.2.1
General
(see appended table 5.2)
P
5.2.2
Test procedure
(see appended table 5.2)
P
Page 24 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
5.3
Abnormal operating and fault conditions
5.3.1
Protection against overload and abnormal
operation
operation
(see appended table 5.3)
P
5.3.2
Motors
No such devices
N/A
5.3.3
Transformers
(see appended table 5.3 and
Annex C)
Annex C)
P
5.3.4 Functional
insulation ...........................................: Methods a), b) and c)
P
5.3.5
Electromechanical components
No such components within
EUT
EUT
N/A
5.3.6
Simulation of faults
(see appended table 5.3)
P
5.3.7
Unattended equipment
There are no thermostats and
similar components within the
EUT
similar components within the
EUT
N/A
5.3.8
Compliance criteria for abnormal operating and
fault conditions
fault conditions
P
Page 25 of 91
ST-05368
IEC 60950-1 / EN 60950-1
Clause
Requirement – Test
Result – Remark
Verdict
TRF No.: IECEN60950_1A
6
CONNECTION TO TELECOMMUNICATION NETWORKS
6.1
Protection of telecommunication network service persons, and users of
other equipment connected to the network, from hazards in the equipment
other equipment connected to the network, from hazards in the equipment
6.1.1
Protection from hazardous voltages
N/A
6.1.2
Separation of the telecommunication network from earth
N/A
6.1.2.1 Requirements
N/A
Test
voltage (V) ..................................................:
Current in the test circuit (mA) .........................:
6.1.2.2 Exclusions ...........................................................:
N/A
6.2
Protection of equipment users from overvoltages on telecommunication
networks
networks
6.2.1 Separation
requirements
N/A
6.2.2
Electric strength test procedure
N/A
6.2.2.1 Impulse
test
N/A
6.2.2.2 Steady-state
test
N/A
6.2.2.3 Compliance
criteria
N/A
6.3
Protection of the telecommunication wiring system from overheating
Max. output current (A) .......................................:
Current
limiting method.......................................:
Click on the first or last page to see other SoundSticks II service manuals if exist.