Page 6 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
1.7 
Marking and instructions 
 
1.7.1 Power 
rating 
 
 
 
Rated voltage(s) or voltage range(s) (V) ............ : 100 – 240 Vac 
 
Symbol for nature of supply, for d.c. only............ : The EUT is supplied by AC 
mains 
N/A 
 
Rated frequency or rated frequency range (Hz)  : 50 / 60 Hz 
 Rated 
current 
(mA 
or A) ..................................... : 1.2 A 
 
Manufacturer’s name or trademark or 
identification mark  .............................................. :
LEI P 
 
Type/model or type reference ............................. : NU40-2******-I3 P 
 
Symbol of for Class II equipment only  ............... :
 
 Other 
symbols 
....................................................: Symbols are used according to 
IEC 60417-1 
 Certification 
marks ............................................. :  
N/A 
1.7.2 
Safety instructions 
The English “I.T.E. POWER 
SUPPLY” will be provided with 
the unit  
1.7.3 
Short duty cycles 
The EUT is continuous 
operating type 
N/A 
1.7.4 
Supply voltage adjustment ................................. : Only one power supply voltage 
range 
N/A 
1.7.5 
Power outlets on the equipment  ........................ : No such components within the 
EUT 
N/A 
1.7.6 Fuse 
identification .............................................. : The “F1” and “T2AL 250V” are 
marked adjacent to the main 
fuse  
1.7.7 Wiring 
terminals 
 
1.7.7.1 Protective 
earthing 
and bonding terminals  ........ : Approved appliance coupler is 
provided 
N/A 
1.7.7.2 
Terminal for a.c. mains supply conductors  
 
N/A 
1.7.7.3 
Terminals for d.c. mains supply conductors 
 
N/A 
1.7.8 Controls 
and 
indicators 
 
1.7.8.1 
Identification, location and marking .................... : No control and indicator within 
the EUT 
N/A 
 
 
 
 
Page 7 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
1.7.8.2 Colours 
 .............................................................. : The LED is illuminated when 
the EUT is operating and colour 
is only used for functional 
indicator 
1.7.8.3 Symbols 
according to IEC 60417........................ :  
N/A 
1.7.8.4 
Markings using figures   ...................................... : No figures used as marking 
N/A 
1.7.9 
Isolation of multiple power sources .................... : Only one power supply 
N/A 
1.7.10 
IT power distribution systems  
Only for Norway 
1.7.11 
Thermostats and other regulating devices  
No such devices within the EUT 
N/A 
1.7.12 Language 
........................................................... : English and local language to 
each country that would be 
marketed 
 
1.7.13 Durability 
 
1.7.14 
Removable parts 
No such parts 
N/A 
1.7.15 
Replaceable batteries 
No battery within the EUT 
N/A 
 Language ............................................................ :  
 
1.7.16 
Operator access with a tool ................................ : No such areas 
N/A 
1.7.17 
Equipment for restricted access locations .......... : The EUT is not such types 
N/A 
 
 
 
 
 
Page 8 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
PROTECTION FROM HAZARDS 
 
 
2.1 
Protection from electric shock and energy hazards 
 
2.1.1 
Protection in operator access areas  
 
2.1.1.1 
Access to energized parts 
See comment below  
 
Test by inspection .............................................. : The concerned hazardous parts 
are not accessible 
 
Test with test finger ............................................ : The concerned hazardous parts 
are not accessible 
 
Test with test pin  ................................................ : Hazardous live parts are not 
accessible 
 
Test with test probe ............................................ : No TNV circuit within the EUT 
N/A 
2.1.1.2 Battery 
compartments ........................................ : No battery compartment within 
the EUT 
N/A 
2.1.1.3 
Access to ELV wiring 
No ELV circuit within the EUT 
N/A 
 
Working voltage (V); minimum distance (mm) 
through insulation 
 
 
2.1.1.4 
Access to hazardous voltage circuit wiring 
 
N/A 
2.1.1.5 Energy 
hazards 
.................................................. : (see appended table 2.1.1.5) 
2.1.1.6 
Manual controls 
No such devices 
N/A 
2.1.1.7 
Discharge of capacitors in equipment 
 
 
Time-constant (s); measured voltage (V)............ : 1 s, 52 Vpeak (limit: measured 
max. voltage 348 Vpeak x 37% 
= 128.7 Vpeak) 
 
2.1.2 
Protection in service access areas 
 
N/A 
2.1.3 
Protection in restricted access locations 
 
N/A 
 
2.2 SELV 
circuits 
 
2.2.1 General 
requirements 
 
2.2.2 
Voltages under normal conditions (V)................. : Measured max. 24.41 Vdc 
2.2.3 
Voltages under fault conditions (V) ..................... : Measured max. 24.35 Vdc  
(see also appended table 5.3) 
2.2.3.1 
Separation by double insulation or reinforced 
insulation (method 1) 
 P 
 
 
 
 
Page 9 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
2.2.3.2 
Separation by earthed screen (method 2) 
 
N/A 
2.2.3.3 
Protection by earthing of the SELV circuit 
(method 3) 
 N/A 
2.2.4 
Connection of SELV circuits to other circuits....... : SELV circuits only connected to 
SELV circuits 
 
2.3 TNV 
circuits 
 
2.3.1 
Limits 
No TNV circuit within the EUT 
N/A 
 
Type of TNV circuits............................................ :  
 
2.3.2 
Separation from other circuits and from 
accessible parts 
 
N/A 
 Insulation 
employed ............................................ :  
 
2.3.3 Separation 
from hazardous voltages 
 
N/A 
 Insulation 
employed ............................................ :  
 
2.3.4 
Connection of TNV circuits to other circuits 
 
N/A 
 Insulation 
employed ............................................ :  
 
2.3.5 
Test for operating voltages generated externally 
 
N/A 
 
2.4 
Limited current circuits 
 
2.4.1 General 
requirements 
 
2.4.2 Limit 
values 
 
 Frequency 
(Hz) ................................................... : See the Note on next page 
 
 Measured 
current (mA) ....................................... : See the Note on next page 
 
 Measured 
voltage 
(V).......................................... : See the Note on next page 
 
 
Measured capacitance (
µF) ................................: Measured max. 3300 pF 
 
2.4.3 
Connection of limited current circuits to other 
circuits 
 N/A 
Page of 105