DOWNLOAD Harman Kardon SoundSticks II Service Manual ↓ Size: 3.58 MB | Pages: 105 in PDF or view online for FREE

Model
SoundSticks II
Pages
105
Size
3.58 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
soundsticks-ii.pdf
Date

Harman Kardon SoundSticks II EMC - CB Certificate ▷ View online

 
 
 
 
Page 2 of 91  
ST-05368 
 
TRF No.: IECEN60950_1A 
 
 
 
Particulars: test item vs. test requirements 
Equipment mobility  ..................................... : Movable (Transportable)  
Operating condition ..................................... : Continuous  
Mains supply tolerance (%) ......................... : + 6 %, + 10 % and – 10 % (the test voltage + 10 % is 
required by the manufacturer) 
Tested for IT power systems  ...................... : Yes  
IT testing, phase-phase voltage (V)  ........... : 230 V for Norway 
Class of equipment ..................................... : Class II 
Mass of equipment (kg) ............................... : 0.23kg 
Protection against ingress of water  ............ : IP20 
Test case verdicts 
 
Test case does not apply to the test object  : N/A (Not Applicable) 
Test item does meet the requirement ......... : P (Pass) 
Test item does not meet the requirement ... : F (Fail) 
Testing 
 
Date of receipt of test item .......................... : December 27, 2005 
Date(s) of performance of test .................... : December 27, 2005 
∼ December 28, 2005 
General remarks 
“This report is not valid as a CB Test Report unless appended by an approved CB Testing 
Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02”.
The test result presented in this report relate only to the object(s) tested. 
This report shall not be reproduced, except in full, without the written approval of the Issuing testing 
laboratory. 
“(see Appendix #)” refers to additional information appended to the report.  
“(see appended table #)” refers to a table appended to the report. 
Throughout this report a comma (point) is used as the decimal separator. 
Additional information 
Additional special deviations of CN (China) of IEC 60950, 3rd ed. are checked. 
 
 
 
 
Page 3 of 91  
ST-05368 
 
TRF No.: IECEN60950_1A 
 
 
 
Copy of marking plate and summary of test results (information/comments): 
(Representative) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note:  
 
The above markings are the minimum requirements required by the safety standard. For the final 
production samples, the additional markings which do not give rise to misunderstanding may be added. 
 
 
I.T.E. POWER SUPPLY 
Model No.: NU40-2100400-I3 
Input: 100-240 V
 50/60 Hz 1.2 A 
Output: 10 V
 4.0 A 
             
   
LEI 
 
 
 
I.T.E. POWER SUPPLY 
Model No.: NU40-2100400-I3 
Input: 100-240 V
 50/60 Hz 1.2 A 
Output: 10 V
 4.0 A 
       
     
  
 
 
LEI  
 
 
I.T.E. POWER SUPPLY 
Model No.: NU40-2240050-I3 
Input: 100-240 V
 50/60 Hz 1.2 A 
Output: 24 V
 0.5 A 
             
   
LEI 
 
 
 
I.T.E. POWER SUPPLY 
Model No.: NU40-2240050-I3 
Input: 100-240 V
 50/60 Hz 1.2 A 
Output: 24 V
 0.5 A 
       
   
    
   
 
LEI  
 
 
I.T.E. POWER SUPPLY 
Model No.: NU40-2050400-I3 
Input: 100-240 V
 50/60 Hz 1.2 A 
Output: 5 V
 4 A 
             
   
LEI 
 
 
 
I.T.E. POWER SUPPLY 
Model No.: NU40-2050400-I3 
Input: 100-240 V
 50/60 Hz 1.2 A 
Output: 5 V
 4 A 
       
   
     
 
 
LEI  
 
 
 
 
Page 4 of 91  
ST-05368 
 
TRF No.: IECEN60950_1A 
 
 
 
Summary of testing: 
1.6.2                      Input current test 
1.7.13                    Marking durability test 
2.1.1.1 b                Finger test 
2.1.1.1 c                Pin test 
2.1.1.5                   Energy hazards test 
2.1.1.7                   Stored discharge on capacitors test 
2.2.2                      Voltages under normal conditions test 
2.2.3                      Voltages under fault conditions test 
2.4                         Limited current circuits test 
2.5                         Limited power sources test 
2.9.2                      Humidity conditioning test 
2.10.2                    Determination of working voltage test 
2.10.3, 2.10.4        Clearances and creepage distances measurements 
2.10.5                    Distance through insulation measurements 
4.1                         EUT stabilization – 10
° tilted test  
4.2.2                      Mechanical strength – steady force test, 10 N 
4.2.4                      Mechanical strength – steady force test, 250 N 
4.2.5                      Mechanical strength – steel ball impact test 
4.2.6                      Mechanical strength – drop test 
4.2.7                      Mechanical strength – stress relief test 
4.5.1                      Normal operating test 
4.5.2                      Ball pressure test 
5.1                         Touch current test 
5.2                         Electric strength test 
5.3                         Abnormal operating and fault conditions test 
 
General product information: 
 For Model NU40-2******-I3: 
a.   The 1
st
 to 3
rd
 “*” denote the output voltage, which can be 050 (5.0 Vdc) to 240 (24 Vdc). 
b.   The 4
th
 to 6
th
 “*” denote the output current, which can be 050 (0.5 A) to 400 (4 A). 
Models NU40-2100400-I3, NU40-2240050-I3 and NU402050400-I3 are tested as the representatives of this 
series. 
.
 
 
 
 
Page 5 of 91 
ST-05368 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.: IECEN60950_1A 
 
 
 
1 GENERAL 
 
 
1.5 Components 
 
1.5.1 General 
 
 
Comply with IEC 60950-1 or relevant component 
standard  
(see appended table 1.5.1) 
1.5.2 
Evaluation and testing of components 
 
1.5.3 
Thermal controls 
No such devices within the EUT 
N/A 
1.5.4 
Transformers 
(see also Annex C) 
1.5.5 Interconnecting 
cables 
The output cord is evaluated at 
the relevant parts of this report 
1.5.6 
Capacitors in primary circuits ............................. : Approved X capacitor, CX1 
(see appended table 1.5.1) 
1.5.7 
Double insulation or reinforced insulation bridged 
by components 
Double or reinforced insulation 
between primary and 
secondary bridged by Y1 
capacitor, CY3 
1.5.7.1 General 
 
1.5.7.2 
Bridging capacitors 
Approved Y1 capacitor, CY3   
(see appended table 1.5.1) 
1.5.7.3 
Bridging resistors 
No such devices within the EUT 
N/A 
1.5.7.4 Accessible 
parts 
 
N/A 
1.5.8 
Components in equipment for IT power systems 
 
N/A 
 
1.6 Power 
interface 
 
1.6.1 
AC power distribution systems 
TN, TT or IT (only for Norway) 
1.6.2 Input 
current 
(see 
appended table 1.6.2)  
1.6.3 
Voltage limit of hand-held equipment 
The EUT is not hand-held 
equipment 
N/A 
1.6.4 
Neutral conductor  
 
 
Page of 105