Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.5.2.2
Add the following sentence before the last
paragraph.
For Fuses according to Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, all that needs to be marked is the rated
current.
paragraph.
For Fuses according to Appendix 3 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material, all that needs to be marked is the rated
current.
N/A
14.5.3
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
(corresponding to IEC 60730-1).
N/A
14.5.4
Replace IEC 60127 by “IEC 60127 or JIS C 6575”.
N/A
14.6.1
Add the following paragraph after NOTE.
The following manually operated mechanical
switches shall meet the requirements specified in
item a) or b) below.
- the controlling current exceeds 0.2 A r.m.s a.c.
The following manually operated mechanical
switches shall meet the requirements specified in
item a) or b) below.
- the controlling current exceeds 0.2 A r.m.s a.c.
or d.c.
- the voltage across the open switch contacts
exceeds 35 Vpeak ac or 24 Vdc.
N/A
14.6.1
In item a), replace IEC 61058-1 by “IEC 61058-1 or
JIS C 4526-1:1999”.
JIS C 4526-1:1999”.
N/A
14.6.2
In item a), replace IEC 61058-1 by “IEC 61058-1 or
JIS C 4526-1:1999”.
JIS C 4526-1:1999”.
N/A
14.6.3
In item a), replace IEC 61058-1 by “IEC 61058-1 or
JIS C 4526-1:1999”.
JIS C 4526-1:1999”.
N/A
14.6.5
In item a), replace IEC 61058-1 by “IEC 61058-1 or
JIS C 4526-1:1999”.
JIS C 4526-1:1999”.
N/A
14.7
Replace IEC 60950 by JIS C 6950:2006.
N/A
Page 11 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
15.1.1
Replace the first and second paragraph by the
following.
Plugs and appliance couplers for the connection of
the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
relevant JIS standards for plugs, socket-outlets,
appliance couplers or interconnection couplers. If
there is no appropriate JIS standard, they shall
comply with the relevant IEC standards.
Appliance connectors, interconnection outlets and
interconnection plug-connectors compiled with
Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material are accepted. In that case,
if due to the shape the contact parts are
connectable to those specified in standard sheets
of IEC 60320-1, they shall comply with dimensions
and ratings specified in the relevant standard
sheets of IEC 60320-1.
Examples of relevant specifications and standards:
- Plugs / Socket-outlets: Appendix 4 of Article 1 of
following.
Plugs and appliance couplers for the connection of
the apparatus to the MAINS and socket-outlets
and interconnection couplers for providing MAINS
power to other apparatus shall comply with the
relevant JIS standards for plugs, socket-outlets,
appliance couplers or interconnection couplers. If
there is no appropriate JIS standard, they shall
comply with the relevant IEC standards.
Appliance connectors, interconnection outlets and
interconnection plug-connectors compiled with
Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material are accepted. In that case,
if due to the shape the contact parts are
connectable to those specified in standard sheets
of IEC 60320-1, they shall comply with dimensions
and ratings specified in the relevant standard
sheets of IEC 60320-1.
Examples of relevant specifications and standards:
- Plugs / Socket-outlets: Appendix 4 of Article 1 of
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. Article
2 (corresponding to IEC 60884) of the
Ordinance.
requirements for the Electrical Appliance. Article
2 (corresponding to IEC 60884) of the
Ordinance.
- Appliance couplers: Appendix 4 of Article 1 of
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. Article
2 (corresponding to IEC 60320-1) of the
Ordinance.
requirements for the Electrical Appliance. Article
2 (corresponding to IEC 60320-1) of the
Ordinance.
- Appliance inlets: IEC 60320-1
- Interconnection outlets: Appendix 4 of Article 1 of
- Interconnection outlets: Appendix 4 of Article 1 of
the Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance. IEC
60320-2-2.
requirements for the Electrical Appliance. IEC
60320-2-2.
- Interconnection couplers: Appendix 4 of Article 1
of the Ministerial Ordinance on stipulating
technical requirements for the Electrical
Appliance.
technical requirements for the Electrical
Appliance.
Delete NOTE 1 and NOTE 2.
See appended table 14.
Pass
15.1.1
Replace the paragraph after NOTE 2 by the
following.
MAINS socket-outlets and interconnection
couplers mounted on CLASS 0I and CLASS II
apparatus shall not permit connection of CLASS I
apparatus.
following.
MAINS socket-outlets and interconnection
couplers mounted on CLASS 0I and CLASS II
apparatus shall not permit connection of CLASS I
apparatus.
N/A
Page 12 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
15.1.1
Replace the paragraph before NOTE 3 by the
following.
MAINS socket-outlets and interconnection
couplers mounted on CLASS I apparatus shall be
provided with protective earthing contacts which
are reliably connected to the PROTECTIVE
EARTHING TERMINAL or contact of the
apparatus. If not, it shall not permit connection of
CLASS I apparatus.
following.
MAINS socket-outlets and interconnection
couplers mounted on CLASS I apparatus shall be
provided with protective earthing contacts which
are reliably connected to the PROTECTIVE
EARTHING TERMINAL or contact of the
apparatus. If not, it shall not permit connection of
CLASS I apparatus.
N/A
15.1.1
Replace NOTE 4 by the following.
NOTE 4 Socket-outlets not allowing the
connection of CLASS I apparatus can be
designed, for instance, similar to IEC 60906-1,
standard sheets 3-1 or 3-2, or according to IEC
60320-2-2, standard sheets D or H.
NOTE 4 Socket-outlets not allowing the
connection of CLASS I apparatus can be
designed, for instance, similar to IEC 60906-1,
standard sheets 3-1 or 3-2, or according to IEC
60320-2-2, standard sheets D or H.
N/A
15.1.2
Delete the following sentence in NOTE.
An example of a connector not meeting the
requirements of this sub clause is the so-called
"banana" plug.
An example of a connector not meeting the
requirements of this sub clause is the so-called
"banana" plug.
N/A
15.1.3
Replace the references, “IEC 60083 [1], IEC
60320, IEC 60884, IEC 60906” by “JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906”.
60320, IEC 60884, IEC 60906” by “JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906”.
N/A
15.2
Add “and CLASS 0I EQUIPMENT” after the words,
“CLASS I EQUIPMENT”
“CLASS I EQUIPMENT”
N/A
15.2
Add the following paragraphs after the first
paragraph.
The external earth wire of plug with an external
earth wire shall not be earthed by a clip.
Rated voltage of plug with an protective external
earth wire shall be less 150 Vac.
paragraph.
The external earth wire of plug with an external
earth wire shall not be earthed by a clip.
Rated voltage of plug with an protective external
earth wire shall be less 150 Vac.
N/A
15.2
Delete the following paragraph.
In SUPPLY APPARATUS of CLASS I with non-
HAZARDOUS LIVE output voltage, output circuits
shall not be connected to the protective earthing
conductor.
In SUPPLY APPARATUS of CLASS I with non-
HAZARDOUS LIVE output voltage, output circuits
shall not be connected to the protective earthing
conductor.
N/A
15.3.1
In the first paragraph, replace IEC 60998-2-2 by
“IEC 60998-2-2 or JIS C 2814-2-2:2001”.
“IEC 60998-2-2 or JIS C 2814-2-2:2001”.
N/A
15.3.1
In the first paragraph, replace IEC 60999 by IEC
60999-1.
60999-1.
N/A
15.3.1
In the third paragraph, replace IEC 60335-1 by JIS
C 9335-1:2003 (corresponding to IEC 60335-1).
C 9335-1:2003 (corresponding to IEC 60335-1).
N/A
15.3.3
Replace “ISO 261 or ISO 262” by “JIS B 0205-
2:2001 or JIS B 0205-3:2001”.
2:2001 or JIS B 0205-3:2001”.
N/A
15.3.5
In the second paragraph, replace IEC 60950 by
JIS C 6950:2006.
JIS C 6950:2006.
N/A
Page 13 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Replace Table 15 by the following.
RATED CURRENT
CONSUMPTION of the
apparatus
a
A
Nominal cross-sectional
area
mm
2
Up to and including 6
0.75 to 1
Over 6 up to and
including 10
including 10
1 to 1.5
Over 10 up to and
including 16
including 16
1.5 to 2.5
a
The RATED CURRENT CONSUMPTION
includes currents which can be drawn from
socket-outlets providing MAINS power for other
apparatus.
socket-outlets providing MAINS power for other
apparatus.
15.3.5
N/A
15.3.9
Add the following to the last of the first paragraph.
This does not apply to CLASS 0I EQUIPMENT
with a protective earthing terminal separately.
This does not apply to CLASS 0I EQUIPMENT
with a protective earthing terminal separately.
N/A
15.4.1
In NOTE 1, replace IEC 60884-1 by JIS C 8282
(corresponding to IEC 60884-1).
(corresponding to IEC 60884-1).
N/A
15.4.1
In NOTE 2, replace IEC 60083 [1] by JIS C 8303.
N/A
15.4.2
In NOTE, replace IEC 60083 [1] by JIS C
8303:1993 [1].
8303:1993 [1].
N/A
15.4.3
Add the following NOTE to Table 17.
NOTE If mains plug is parallel blade, a pull force
as given in “Over 10 A up to and including 16 A,
130/250 V” of Table 17 is applied.
NOTE If mains plug is parallel blade, a pull force
as given in “Over 10 A up to and including 16 A,
130/250 V” of Table 17 is applied.
N/A
16.1
Add the following to the last of first paragraph.
Or mains cords shall be of the sheathed type
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance..
Delete NOTE 1.
Replace the second paragraph by the following.
Compliance is checked by testing MAINS supply
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance.
Or mains cords shall be of the sheathed type
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance..
Delete NOTE 1.
Replace the second paragraph by the following.
Compliance is checked by testing MAINS supply
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance.
See appended table 14.
Pass
16.1
In this sub-clause, replace IEC 60227 by JIS C
3662 (corresponding to IEC 60227).
In this sub-clause, replace IEC 60245 by JIS C
3663 (corresponding to IEC 60245).
3662 (corresponding to IEC 60227).
In this sub-clause, replace IEC 60245 by JIS C
3663 (corresponding to IEC 60245).
N/A