Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
ATTACHMENT 2 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.5.2.2 
Add the following sentence before the last 
paragraph. 
For Fuses according to Appendix 3 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance and 
Material, all that needs to be marked is the rated 
current. 
 N/A 
14.5.3 
Replace IEC 60730-1 by JIS C 9730-1 
(corresponding to IEC 60730-1). 
 N/A 
14.5.4 
Replace IEC 60127 by “IEC 60127 or JIS C 6575”.  
N/A 
14.6.1 
Add the following paragraph after NOTE. 
The following manually operated mechanical 
switches shall meet the requirements specified in 
item a) or b) below. 
-  the controlling current exceeds 0.2 A r.m.s a.c. 
or d.c. 
-  the voltage across the open switch contacts 
exceeds 35 Vpeak ac or 24 Vdc.   
 N/A 
14.6.1 
 
 
In item a), replace IEC 61058-1 by “IEC 61058-1 or 
JIS C 4526-1:1999”. 
 N/A 
14.6.2 
In item a), replace IEC 61058-1 by “IEC 61058-1 or 
JIS C 4526-1:1999”. 
 N/A 
14.6.3 
In item a), replace IEC 61058-1 by “IEC 61058-1 or 
JIS C 4526-1:1999”. 
 N/A 
14.6.5 
In item a), replace IEC 61058-1 by “IEC 61058-1 or 
JIS C 4526-1:1999”. 
 N/A 
14.7 
Replace IEC 60950 by JIS C 6950:2006. 
 
N/A 
Page 11 of 15 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
ATTACHMENT 2 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
15.1.1 
Replace the first and second paragraph by the 
following. 
Plugs and appliance couplers for the connection of 
the apparatus to the MAINS and socket-outlets 
and interconnection couplers for providing MAINS 
power to other apparatus shall comply with the 
relevant JIS standards for plugs, socket-outlets, 
appliance couplers or interconnection couplers. If 
there is no appropriate JIS standard, they shall 
comply with the relevant IEC standards. 
Appliance connectors, interconnection outlets and 
interconnection plug-connectors compiled with 
Appendix 3 of the Ministerial Ordinance on 
stipulating technical requirements for the Electrical 
Appliance and Material are accepted. In that case, 
if due to the shape the contact parts are 
connectable to those specified in standard sheets 
of IEC 60320-1, they shall comply with dimensions 
and ratings specified in the relevant standard 
sheets of IEC 60320-1. 
Examples of relevant specifications and standards:
- Plugs / Socket-outlets: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. Article 
2 (corresponding to IEC 60884) of the 
Ordinance. 
-  Appliance couplers: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. Article 
2 (corresponding to IEC 60320-1) of the 
Ordinance. 
-  Appliance inlets: IEC 60320-1 
- Interconnection outlets: Appendix 4 of Article 1 of 
the Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance. IEC 
60320-2-2.  
- Interconnection couplers: Appendix 4 of Article 1 
of the Ministerial Ordinance on stipulating 
technical requirements for the Electrical 
Appliance.  
Delete NOTE 1 and NOTE 2. 
See appended table 14. 
Pass 
15.1.1 
Replace the paragraph after NOTE 2 by the 
following. 
MAINS socket-outlets and interconnection 
couplers mounted on CLASS 0I and CLASS II 
apparatus shall not permit connection of CLASS I 
apparatus. 
 N/A 
Page 12 of 15 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
ATTACHMENT 2 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
15.1.1 
Replace the paragraph before NOTE 3 by the 
following. 
MAINS socket-outlets and interconnection 
couplers mounted on CLASS I apparatus shall be 
provided with protective earthing contacts which 
are reliably connected to the PROTECTIVE 
EARTHING TERMINAL or contact of the 
apparatus. If not, it shall not permit connection of 
CLASS I apparatus. 
 N/A 
15.1.1 
Replace NOTE 4 by the following. 
NOTE 4  Socket-outlets not allowing the 
connection of CLASS I apparatus can be 
designed, for instance, similar to IEC 60906-1, 
standard sheets 3-1 or 3-2, or according to IEC 
60320-2-2, standard sheets D or H. 
 N/A 
15.1.2 
Delete the following sentence in NOTE.  
An example of a connector not meeting the 
requirements of this sub clause is the so-called 
"banana" plug. 
 N/A 
15.1.3 
Replace the references, “IEC 60083 [1], IEC 
60320, IEC 60884, IEC 60906” by “JIS C 8282 
(corresponding to IEC 60884), JIS C 8303, IEC 
60320 and IEC 60906”. 
 N/A 
15.2 
Add “and CLASS 0I EQUIPMENT” after the words, 
“CLASS I EQUIPMENT” 
 N/A 
15.2 
Add the following paragraphs after the first 
paragraph. 
The external earth wire of plug with an external 
earth wire shall not be earthed by a clip. 
Rated voltage of plug with an protective external 
earth wire shall be less 150 Vac. 
 N/A 
15.2 
Delete the following paragraph. 
In SUPPLY APPARATUS of CLASS I with non-
HAZARDOUS LIVE output voltage, output circuits 
shall not be connected to the protective earthing 
conductor. 
 N/A 
15.3.1 
In the first paragraph, replace IEC 60998-2-2 by 
“IEC 60998-2-2 or JIS C 2814-2-2:2001”. 
 N/A 
15.3.1 
In the first paragraph, replace IEC 60999 by IEC 
60999-1. 
 N/A 
15.3.1 
In the third paragraph, replace IEC 60335-1 by JIS 
C 9335-1:2003 (corresponding to IEC 60335-1). 
 N/A 
15.3.3 
Replace “ISO 261 or ISO 262” by “JIS B 0205-
2:2001 or JIS B 0205-3:2001”. 
 N/A 
15.3.5 
In the second paragraph, replace IEC 60950 by 
JIS C 6950:2006. 
 N/A 
Page 13 of 15 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
ATTACHMENT 2 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Replace Table 15 by the following. 
 
 
 
 
RATED CURRENT 
CONSUMPTION of the 
apparatus 
a
 
Nominal cross-sectional 
area 
mm
2
 
 
Up to and including 6 
0.75 to 1 
 
Over 6 up to and 
including 10 
1     to  1.5 
 
Over 10 up to and 
including 16 
1.5  to  2.5 
 
 The RATED CURRENT CONSUMPTION 
includes currents which can be drawn from 
socket-outlets providing MAINS power for other 
apparatus. 
15.3.5 
 
 
 
 N/A 
15.3.9 
Add the following to the last of the first paragraph. 
This does not apply to CLASS 0I EQUIPMENT 
with a protective earthing terminal separately. 
 N/A 
15.4.1 
In NOTE 1, replace IEC 60884-1 by JIS C 8282 
(corresponding to IEC 60884-1). 
 N/A 
15.4.1 
In NOTE 2, replace IEC 60083 [1] by JIS C 8303. 
 
N/A 
15.4.2 
In NOTE, replace IEC 60083 [1] by JIS C 
8303:1993 [1]. 
 N/A 
15.4.3 
Add the following NOTE to Table 17. 
NOTE If mains plug is parallel blade, a pull force 
as given in  “Over 10 A up to and including 16 A, 
130/250 V” of Table 17 is applied. 
 N/A 
16.1 
Add the following to the last of first paragraph. 
Or mains cords shall be of the sheathed type 
complying with Appendix 1 of Article 1 of the 
Ministerial Ordinance on stipulating technical 
requirements for the Electrical Appliance..  
Delete NOTE 1. 
Replace the second paragraph by the following. 
Compliance is checked by testing MAINS supply 
flexible cords in accordance with JIS C 3662 
(corresponding to IEC60227) or JIS C 3663 
(corresponding to IEC 60245) or Appendix 1 of 
Article 1 of the Ministerial Ordinance on stipulating 
technical requirements for the Electrical Appliance.  
See appended table 14. 
Pass 
16.1 
In this sub-clause, replace IEC 60227 by JIS C 
3662 (corresponding to IEC 60227). 
In this sub-clause, replace IEC 60245 by JIS C 
3663 (corresponding to IEC 60245). 
 N/A 