Harman Kardon SB 26 (serv.man3) EMC - CB Certificate ▷ View online
Page 6 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
National Differences – Japan, J60065 (H23)
1.1.3
Add the following as a NOTE after the first sentence.
NOTE 1 In Japan, the requirements for regions
with moderate apply.
with moderate apply.
Pass
2.4.9
In NOTE 1, replace “see 4.2.2 of IEC 62151” by
“see 4.2.2 of IEC 62151 [27]”.
“see 4.2.2 of IEC 62151 [27]”.
N/A
2.6.2A
Add this sub clause.
CLASS 0I EQUIPMENT: Equipment which has, as
for protection against electric shock,
for protection against electric shock,
- at least using BASIC INSULATION, and
- providing a means of connecting to the
protective earthing conductor in the building wiring
those conductive parts that are otherwise capable
of assuming HAZARDOUS VOLTAGES if the
BASIC INSULATION fails, and
protective earthing conductor in the building wiring
those conductive parts that are otherwise capable
of assuming HAZARDOUS VOLTAGES if the
BASIC INSULATION fails, and
- using a supply cord without earthing conductor
or a plug without earthing pin.
Apparatus provided with a cord set having a two-
pin type plug with a lead wire for earthing or having
three pin - tow pin adaptor is also regarded as
Class 0I.
NOTE Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation.
or a plug without earthing pin.
Apparatus provided with a cord set having a two-
pin type plug with a lead wire for earthing or having
three pin - tow pin adaptor is also regarded as
Class 0I.
NOTE Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation.
N/A
3.2
Add the “Class 0I equipment” in the first sentence of
this sub-clause.
this sub-clause.
N/A
3.2
Add the following after the first sentence of this
sub-clause.
NOTE Equipment often transported and used
should not be Class I equipment nor Class 0I
equipment.
sub-clause.
NOTE Equipment often transported and used
should not be Class I equipment nor Class 0I
equipment.
N/A
4.2.8
Delete this clause.
N/A
4.3.4, b)
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
(corresponding to IEC 60730-1).
N/A
4.3.12
Delete this clause.
N/A
4.3.13
Replace “250 V a.c.” by “the maximum of the
variable range”.
variable range”.
N/A
Page 7 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
National Differences – Japan, J60065 (H23)
5.4.2A
For CLASS 0I EQUIPMENT, the following
instruction shall be indicated where readily visible
on the mains plug or the product:
“WARNING: Provide an earthing connection”
Example in Japanese:
instruction shall be indicated where readily visible
on the mains plug or the product:
“WARNING: Provide an earthing connection”
Example in Japanese:
Moreover, for CLASS 0I EQUIPMENT, the
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
“WARNING: Provide an earthing connection
before the mains plug is connected to the mains.
And, when disconnecting the earthing connection,
be sure to disconnect after pulling out the mains
plug from the mains.”
Example in Japanese:
N/A
6.2
In NOTE 1, replace IEC 61040 [10] by JIS C
6181:1995 [10].
6181:1995 [10].
N/A
7.1.5
Add the words, “without dimensions restrictions”
after the figure, “65 K” in the first sentence of
Condition “b” in Table 3 as follows.
For parts not likely to be touched during intended
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
after the figure, “65 K” in the first sentence of
Condition “b” in Table 3 as follows.
For parts not likely to be touched during intended
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
N/A
Page 8 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
National Differences – Japan, J60065 (H23)
7.1.5
Add the following paragraph as 2
nd
paragraph of
Condition “d “in Table 3.
For materials which are not listed in Table 3,
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements for
the Electrical Appliance and Material. Permissible
temperature rise of “Supply cords and wiring
insulation” is applicable only to the materials used
in supply cords complying with JIS C 3662
(corresponding to IEC 60227) or JIS C 3663
(corresponding to IEC 60245). Materials used in
other wiring shall comply with item 3 of detailed
regulations, 1.(1).b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements for
the Electrical Appliance and Material.
For materials which are not listed in Table 3,
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements for
the Electrical Appliance and Material. Permissible
temperature rise of “Supply cords and wiring
insulation” is applicable only to the materials used
in supply cords complying with JIS C 3662
(corresponding to IEC 60227) or JIS C 3663
(corresponding to IEC 60245). Materials used in
other wiring shall comply with item 3 of detailed
regulations, 1.(1).b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements for
the Electrical Appliance and Material.
Pass
7.1.5
In the first paragraph of Condition “f” of Table 3,
add ”JIS K 7206:1999 or” before the reference,
ISO 306.
add ”JIS K 7206:1999 or” before the reference,
ISO 306.
Pass
7.1.5
In Condition “f,” 1) of Table 3, add ”JIS K
7206:1999 or” before the reference, ISO 306.
7206:1999 or” before the reference, ISO 306.
Pass
7.2
In NOTE 2, add “or JIS standard (identical to or
modified IEC)” after the word, IEC standard.
modified IEC)” after the word, IEC standard.
N/A
8.5
In the first paragraph, add “and Class 0I
Equipment” after the words, Class I Equipment.
Equipment” after the words, Class I Equipment.
N/A
8.5
In the six paragraph (before NOTE 3), add the
following to the end of the first sentence.
CLASS 0I EQUIPMENT shall be provided with a
protective earthing terminal at any point outside
the apparatus where easily visible or a protective
external earth wire from mains plug.
following to the end of the first sentence.
CLASS 0I EQUIPMENT shall be provided with a
protective earthing terminal at any point outside
the apparatus where easily visible or a protective
external earth wire from mains plug.
N/A
8.11
In NOTE 2, c), add “or JIS C 2107, JIS C 2336, JIS
C 2338” after the reference, IEC 60454.
C 2338” after the reference, IEC 60454.
N/A
9.1.1.1
In the last paragraph, add the following sentence
after the first sentence.
For CLASS 0I EQUIPMENT, the r.m.s. TOUCH-
CURRENT to earth shall not be more than 1.0 mA.
after the first sentence.
For CLASS 0I EQUIPMENT, the r.m.s. TOUCH-
CURRENT to earth shall not be more than 1.0 mA.
N/A
10
In NOTE, replace “IEC 60664-1 and IEC 60664-4
[9]” by “JIS C 0664:2003 and IEC/TR3 60664-4 [8]”
[9]” by “JIS C 0664:2003 and IEC/TR3 60664-4 [8]”
Pass
10.1
Add “CLASS 0I EQUIPMENT and” to the head of
the first paragraph.
the first paragraph.
N/A
Page 9 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
In Table 5, add the following values to the sub-
table of NOTE.
table of NOTE.
Test voltage (peak)
Operating
Voltage U
(peak)
Curve A Curve B
142 V
1 414 V
2 828 V
10.3.2
See appended table 10.3.
Pass
11.2.1
Add the following after the original NOTE.
NOTE 2 Fuses except for the ones according to
IEC 60127 shall be tested in consideration of the
characteristic.
NOTE 2 Fuses except for the ones according to
IEC 60127 shall be tested in consideration of the
characteristic.
See appended table 11.2.
Pass
11.2.3
Add “and CLASS 0I” after the words, CLASS I.
N/A
13.4
In NOTE 2 of Table 11, replace IEC 60664-1 by
JIS C 0664:2003 (corresponding to IEC 60664-1).
JIS C 0664:2003 (corresponding to IEC 60664-1).
See appended table 11.2.
Pass
14.3.3.2
In the second sentence of the first paragraph, add
“or JIS C 2107, JIS C 2336 and JIS C 2338” after
the reference, IEC 60454.
“or JIS C 2107, JIS C 2336 and JIS C 2338” after
the reference, IEC 60454.
N/A
14.5.1.1
In item a), add “JIS C 9730 series or” before the
reference, IEC 60730 series.
reference, IEC 60730 series.
N/A
14.5.1.2
In the first sentence of item a), replace “IEC
60691” by “IEC 60691, JIS C 6691:2003 or
Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material”.
60691” by “IEC 60691, JIS C 6691:2003 or
Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material”.
N/A
14.5.1.2
After the second sentence of item a), replace “IEC
60691” by “JIS C 6691:2003 or IEC 60691”.
60691” by “JIS C 6691:2003 or IEC 60691”.
N/A
14.5.2.1
Replace the first and the second sentence as
follows:
Fuse-links, DIRECTLY CONNECTED TO THE
MAINS, used in order to prevent the apparatus
from becoming unsafe within the sense of this
standard shall comply with
- the relevant part of IEC 60127 or JIS C 6575,
unless they have a rated current outside the range
specified in that standard. In the latter case, they
shall comply with the relevant part of IEC 60127 or
JIS C 6575 as far as applicable, or
- Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material (limited to Fuses with the
rated current of 1 A or more).
follows:
Fuse-links, DIRECTLY CONNECTED TO THE
MAINS, used in order to prevent the apparatus
from becoming unsafe within the sense of this
standard shall comply with
- the relevant part of IEC 60127 or JIS C 6575,
unless they have a rated current outside the range
specified in that standard. In the latter case, they
shall comply with the relevant part of IEC 60127 or
JIS C 6575 as far as applicable, or
- Appendix 3 of the Ministerial Ordinance on
stipulating technical requirements for the Electrical
Appliance and Material (limited to Fuses with the
rated current of 1 A or more).
See appended table 14.
Pass