Harman Kardon SB 26 (serv.man3) EMC - CB Certificate ▷ View online
Page 2 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
The needle-flame test shall not be carried out on
parts of material classified as V-0 or V-1
according to AS/NZS 60695.11.10 provided that
the sample tested was not thicker than the
relevant part.
parts of material classified as V-0 or V-1
according to AS/NZS 60695.11.10 provided that
the sample tested was not thicker than the
relevant part.
N/A
20.201.2.3 Testting by needle-flame test
N/A
If parts, other than enclosures, do not withstand the
glow wire tests of 20.201.2.2, by failure to
extinguish within 30 s after the removal of the glow-
wire tip, the needle-flame test detailed in
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of
50 mm or which are likely to be impinged upon by
flame during the tests of 20.201.2.2.
glow wire tests of 20.201.2.2, by failure to
extinguish within 30 s after the removal of the glow-
wire tip, the needle-flame test detailed in
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of
50 mm or which are likely to be impinged upon by
flame during the tests of 20.201.2.2.
N/A
20.201.2.4 Testing of printed boards
N/A
Material of printed circuit boards on which the
available power exceeds 15 VA at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets V-
1 or better to AS/NZS 60695.11.10, unless used in a
fire enclosure
available power exceeds 15 VA at a voltage
between 50 V and 400 V (peak) a.c. or d.c. meets V-
1 or better to AS/NZS 60695.11.10, unless used in a
fire enclosure
N/A
Material of printed circuit boards on which the
available power exceeds 15 VA at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to AS/NZS
60695.11.10
available power exceeds 15 VA at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to AS/NZS
60695.11.10
N/A
21.201.3
For open circuit voltages greater than 4kV
N/A
Potential
ignition
sources
with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
enclosure to V-1
N/A
ANNEX B Apparatus to be connected to the
TELECOMMUNICATION NETWORKS
For Australia only, this Annex is replaced by the
requirements of the Telecommunications
Labelling Notice issued under the
Telecommunications Act.
For Australia only, this Annex is replaced by the
requirements of the Telecommunications
Labelling Notice issued under the
Telecommunications Act.
Not connected to
telecommunication network
telecommunication network
N/A
Page 3 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
ZZ.2
Australian differences (Amend. No.1 to AS/NZS 60065:2003)
-
19.201
Additional stability requirements for television
receivers
(This clause forms part of the Standard 12
months from 31 January, 2008)
receivers
(This clause forms part of the Standard 12
months from 31 January, 2008)
N/A
19.201.1
Warning notice in instructions
N/A
Warning notice on the apparatus
N/A
19.201.2 Restraining
device
(This clause forms part of the Standard 18
months from 31 January, 2008)
months from 31 January, 2008)
N/A
19.201.2.1 Television receiver is provided with a restraining
device
N/A
19.201.2.2 Information and capable of withstanding a pull of
100N
N/A
Label on the product
N/A
19.201.3 Glass
slide
test
(This clause forms part of the Standard 5 years
from 31 January, 2008)
from 31 January, 2008)
N/A
-
Korea Deviation (CB Bulletin, May 31, 2012)
-
5.101
Other Marking: Wording
or an information
regulated in IEC Publication 417 giving high voltage
warning to layman shall be marked, if an apparatus
contains a part more than 600 volts.
warning to layman shall be marked, if an apparatus
contains a part more than 600 volts.
N/A
15.1.1
Plugs for the connection of the apparatus to the
supply mains and socket outlets for providing mains
power to other apparatus shall comply with the
Korean requirement (KSC8300 and 8305)
power to other apparatus shall comply with the
Korean requirement (KSC8300 and 8305)
Shall be evaluated when
submitted for national
approval.
submitted for national
approval.
N/A
31.
Radio frequency interference
The apparatus shall comply with the relevant
The apparatus shall comply with the relevant
CISPR requirements (EMC=EMI+EMS)
Note: The measurement of
radio frequency interference is
not covered in this test report.
radio frequency interference is
not covered in this test report.
N/A
Page 4 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
ATTACHMENT TO TEST REPORT IEC 60065
MALAYSIA NATIONAL DIFFERENCES
Audio, Video and similar apparatus
Differences according to ...............:
IEC 60065
Attachment Form No......................:
MY_ND_IEC60065A
Attachment Originator ...................:
SIRIM QAS International Sdn. Bhd.
Master Attachment .........................:
2008-05
Copyright © 2008 IEC System for Conformity Testing and Certification of Electrical Equipment
(IECEE), Geneva, Switzerland. All rights reserved.
(IECEE), Geneva, Switzerland. All rights reserved.
No.
Requirement - Test
Result - Remark
Verdict
Special
Requirements
-
1.
Appliance shall be subjected to test under tropical
conditions as specified in the related standards
conditions as specified in the related standards
Considered. Pass
2.
Appliance shall be marked with rated voltage 240 V
or voltage range incorporating 240V
Marking at 220V or 230V only is not allowed
or voltage range incorporating 240V
Marking at 220V or 230V only is not allowed
100-240V Pass
3.
Mains frequency is 50Hz
50/60Hz
Pass
4.
Tests shall be conducted at 240V
Pass
5.
Tests shall be conducted at 25 ± 5 ºC, unless
otherwise specified in the standards
otherwise specified in the standards
Pass
6.
The rated power input shall be the corresponding
value measured at 240 V, 50 Hz
value measured at 240 V, 50 Hz
Pass
7.
Appliances shall use the following plug:
Pass
a) 13A fused plugs complying to MS 589 or
BS1363 OR
BS1363 OR
See appended Table 14.
Pass
b) 2.5A, 250V, flat non rewireable two pole plugs
with cord for connection of class II equipment
complying to MS 1578 or BS EN 50075 OR
with cord for connection of class II equipment
complying to MS 1578 or BS EN 50075 OR
See appended Table 14.
Pass
c) 15A, plugs complying to MS 1577
N/A
8.
Class 0 and 01 are not allowed
Class II equipment.
Pass
9.
The supply cords shall comply to MS 140 or BS
6500 or IEC 60227-5 (PVC insulated cords) or IEC
60245-4 (Rubber insulated cords)
6500 or IEC 60227-5 (PVC insulated cords) or IEC
60245-4 (Rubber insulated cords)
Pass
10.
Standard colour code of supply cables: "Brown"
for Live, "Blue" for Neutral, “Green” or
"combination of Green &Yellow" for Earth
for Live, "Blue" for Neutral, “Green” or
"combination of Green &Yellow" for Earth
Pass
11.
Instruction manual shall be in Malay Language
and /or English
and /or English
English. Pass
Specific Requirements to IEC 60065
-
5 MARKING
5.1
Identification and supply ratings
Pass
Page 5 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Rated current or power consumption .....................:
Pass
Measured consumption at 240 V, 50Hz not
exceeding the marked value by more than 10%
exceeding the marked value by more than 10%
Pass
7
HEATING UNDER NORMAL CONDITIONS
7.1
Temperature rises not exceeding specified values
(Table 3 – Normal Conditions)
For tropical climates; permissible temperatures
shall be reduced with 10K
The values of the temperature rises are based on a
maximum ambient temperature of 45
(Table 3 – Normal Conditions)
For tropical climates; permissible temperatures
shall be reduced with 10K
The values of the temperature rises are based on a
maximum ambient temperature of 45
°C for tropical
climates
Pass
10 INSULATION
REQUIREMENTS
10.2 Humidity
treatment
For tropical conditions; 120 hours, 90-95% RH,
40
40
±2°C
Pass
10.3
Insulation resistance and dielectric strength
Pass
11 FAULT
CONDITIONS
11.2
Heating under fault conditions
Temperature rises not exceeding specified values
(Table 3 – Fault conditions)
For tropical climates; permissible temperatures
shall be reduced with 10K
Temperature rises not exceeding specified values
(Table 3 – Fault conditions)
For tropical climates; permissible temperatures
shall be reduced with 10K
Pass