Report No.: ACSCBAV13004
ATTACHMENT 1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
13.3.1
NO: To the second paragraph the following is
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
N/A
15.1.1
(A11:2008)
(A11:2008)
Denmark
The text of the Danish SNC in EN 60065:2002 has
been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with the
Heavy Current Regulations, Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet DKA
1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
Justification: Heavy Current Regulations, Section
107-2-D1
The text of the Danish SNC in EN 60065:2002 has
been modified as follows:
To the first paragraph the following is added:
In Denmark, supply cords of single-phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with the
Heavy Current Regulations, Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall be in accordance with the Heavy Current
Regulation, Section 107-2-D1 standard sheet DKA
1-4a.
Other current ratings socket outlets shall be in
compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DKA 1-3a or DKA
1-3b.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulation,
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a
or DK 1-7a.
Justification: Heavy Current Regulations, Section
107-2-D1
Pass
15.1.1
IE: Apparatus which is fitted with a flexible cable or
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification: SI 525: 1997
N/A
Page 14 of 15
Report No.: ACSCBAV13004
ATTACHMENT 1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
15.1.1
NO: Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as a applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as a applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
§ 24 Mechanical strength
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall be
tested
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall be
tested
Justification: Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
N/A
15.1.1
UK: Apparatus which is fitted with a flexible cable
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification: SI 1768: 1994
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification: SI 1768: 1994
Pass
Page 15 of 15
Report No.: ACSCBAV13004
ATTACHMENT 1
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
J.2
NO: After Table J.1 the following is added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
N/A
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN)
-
5.1
IT: Additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT:User instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: Certification number on the back cover
N/A
6.1
DE: The following requirement applies:
For the operation of any cathode ray tube intended
for the display of visual images operating at an
acceleration voltage exceeding 40 kV, authorization
is required, or application of type approval
(Bauartzulassung) and marking.
Justification: German ministerial decree against
ionizing radiation (Röntgenverordnung), in force
since 2002-07-01, implementing the European
Directive 96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt,
Bundesallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet: http://www.ptb.de
For the operation of any cathode ray tube intended
for the display of visual images operating at an
acceleration voltage exceeding 40 kV, authorization
is required, or application of type approval
(Bauartzulassung) and marking.
Justification: German ministerial decree against
ionizing radiation (Röntgenverordnung), in force
since 2002-07-01, implementing the European
Directive 96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt,
Bundesallee 100, D-38116 Braunschweig, Tel.:
Int+49-531-592-6320, Internet: http://www.ptb.de
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
thermostats, relays and level controllers are not
allowed.
Justification: Ordinance (1990:944) on Prohibition
in Connection with handling. Importation and
exportation of Chemical Products (Certain Cases)
N/A
Page 1 of 15
Report No.: ACSCBAV13004
ATTACHMENT 2
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
ZZ
Australian Deviation (CB Bulletin data base April 26, 2010)
-
7.15
Alternative to the method described in footnote f)
N/A
7.2
Alternative to the method described in footnote h)
N/A
15.1.1
Plugs for the connection of apparatus to mains-
powered socket-outlets shall comply with AS/NZS
3112 or AS/NZS 3123.
powered socket-outlets shall comply with AS/NZS
3112 or AS/NZS 3123.
See appended table 14.
(SB26 SUB)
(SB26 SUB)
Pass
15.3.5
In Table 15, in the second and third rows of the first
column replace ‘6’ with ‘7.5’
column replace ‘6’ with ‘7.5’
Detachable supply cord.
(SB26 SUB)
(SB26 SUB)
N/A
16.2
In Table 18, in the second and third rows of the first
column replace ‘6’ with ‘7.5’.
column replace ‘6’ with ‘7.5’.
Pass
16.3
A flexible cord complying with AS/NZS 3191 need
not undergo this test.
not undergo this test.
N/A
20.1.4
In Table 21, in the third and fourth columns change
both ‘HB75’ and ‘No requirement’ to ‘V-1’.
both ‘HB75’ and ‘No requirement’ to ‘V-1’.
Pass
20.201
Resistance to fire - Alternative tests
N/A
20.201.1
General – “Parts of non-metalic material”
N/A
a) Exemption for components contained in an
enclosure of material V-0 to AS/NZS 60695.11.10
with openings not exceeding 1 mm in width
enclosure of material V-0 to AS/NZS 60695.11.10
with openings not exceeding 1 mm in width
No PIS.
N/A
b) Exemption for small components as defined in
20.201.1
20.201.1
N/A
20.201.2 Tests
N/A
20.201.2.1 Testing of non-metalic parts
N/A
Part of non-metallic material shall be subject to the
glow-wire test of AS/NZS 60695.2.11
which shall be carried out at 550°C.
glow-wire test of AS/NZS 60695.2.11
which shall be carried out at 550°C.
N/A
20.201.2.2 Testing of insulated parts
N/A
Part of insulating material supporting
POTENTIAL
IGNITION SOURCES
shall be subject to the glow wire
test of AS/NZS 60695.2.11 which shall be carried
out at 750°C.
The test shall be also carried out on other parts of
insulating material which are within a
distance of 3 mm of the connection.
out at 750°C.
The test shall be also carried out on other parts of
insulating material which are within a
distance of 3 mm of the connection.
N/A
For parts which withstand the glow-wire test but
produce a flame, other parts above the
connection within the envelope of a vertical cylinder
having a diameter of 20 mm and a height of 50 mm
shall be subjected to the needle-flame test.
However, parts shielded by a barrier
which meets the needle-flame test need not be
tested.
The needle-flame test shall be made in accordance
with AS/NZS 4695.2.2 with the following
modifications: Clause of AS/NZS 4695.2.2
(“5/Severities”, “8/Test procedure”,
“10/Evaluation of test results”)
produce a flame, other parts above the
connection within the envelope of a vertical cylinder
having a diameter of 20 mm and a height of 50 mm
shall be subjected to the needle-flame test.
However, parts shielded by a barrier
which meets the needle-flame test need not be
tested.
The needle-flame test shall be made in accordance
with AS/NZS 4695.2.2 with the following
modifications: Clause of AS/NZS 4695.2.2
(“5/Severities”, “8/Test procedure”,
“10/Evaluation of test results”)
N/A
Click on the first or last page to see other SB 26 (serv.man3) service manuals if exist.