Harman Kardon SB 26 (serv.man3) EMC - CB Certificate ▷ View online

Page 13 of 15 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
ATTACHMENT 1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
13.3.1 
 
NO: To the second paragraph the following is 
added: 
In Norway, due to the IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230 V in case of a single earth fault. 
Justification: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
 N/A 
15.1.1 
(A11:2008) 
 
Denmark  
The text of the Danish SNC in EN 60065:2002 has 
been modified as follows:  
To the first paragraph the following is added:  
In Denmark, supply cords of single-phase 
appliances having a rated current not exceeding 13 
A shall be provided with a plug according to the 
Heavy Current Regulations Section 107-2-D1.  
Appliances of CLASS I provided with socket-outlets 
with earth contact or which are intended to be used 
in locations where protection against indirect 
contact is required according to the wiring rules 
shall be provided with a plug in accordance with the 
Heavy Current Regulations, Section 107-2-D1 
standard sheet DK 2-1a.  
To the second paragraph the following is added:  
Socket outlets intended for providing power to 
CLASS II apparatus with a rated current of 2,5 A 
shall be in accordance with the Heavy Current 
Regulation, Section 107-2-D1 standard sheet DKA 
1-4a.  
Other current ratings socket outlets shall be in 
compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DKA 1-3a or DKA 
1-3b.  
To the third paragraph the following is added:  
Mains socket-outlets with earthing contact shall be 
in compliance with the Heavy Current Regulation, 
Section 107-2-D1 standard sheet DK 1-3a, DK 1-5a 
or DK 1-7a.  
Justification: Heavy Current Regulations, Section 
107-2-D1 
 Pass 
15.1.1 
IE: Apparatus which is fitted with a flexible cable or 
cord shall be provided with a 13 A plug in 
accordance with Statutory Instrument 525:97, “13 A  
Plugs and Conversion Adapters for Domestic Use 
Regulations:1997. 
Justification: SI 525: 1997
 
 N/A 
Page 14 of 15 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
ATTACHMENT 1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
15.1.1 
 
NO: Mains socket-outlets mounted on CLASS II 
apparatus shall comply with the specifications 
given in CEE Publ. 7 as far as a applicable, with 
the following amendments: 
§ 8 Dimensions 
a 2.5 A 250 V two-pole socket-outlets for electronic 
apparatus shall comply with the enclosed Standard 
Sheet I. 
 
§ 24 Mechanical strength 
A 2,5 A 250 V socket-outlets for CLASS II 
electronic apparatus are tested as specified in 
12.1.3 of EN 60065. Also the protecting rim shall be 
tested 
Justification: Act of 24 May 1929 relating to 
supervision of electrical installation (TEA 1929/FEL 
1998). 
 N/A 
15.1.1  
 
 
UK: Apparatus which is fitted with a flexible cable 
or cord and is designed to be connected to a mains 
socket conforming to BS 1363 by means of that 
flexible cable or cord and plug shall be fitted with 
a ”standard plug” in accordance with Statutory 
Instrument 1768: 1994: The Plugs and Sockets etc. 
(Safety) Regulations 1994, unless exempted by 
those Regulations. 
NOTE ”Standard plug” is defined in SI 1768:1994 
and essentially means an approved plug 
conforming to BS 1363 or an approved conversion 
plug. 
Justification: SI 1768: 1994 
 Pass 
Page 15 of 15 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
ATTACHMENT 1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
J.2 
NO: After Table J.1 the following is added: 
In Norway, due to the IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230 V in case of a single earth fault. 
Justification: Based on a use in Norway of an IT 
power distribution system where the neutral is not 
provided. 
 N/A 
 
ZC 
ANNEX ZC TO EN 60065, A-DEVIATIONS (EN) 
- 
5.1 
 
IT: Additional markings on the outside of the TV 
receiver in Italian language 
 N/A 
 
IT:User instructions in Italian language including a 
conformity declaration 
 N/A 
 
IT: Certification number on the back cover 
 
N/A 
6.1 
 
DE: The following requirement applies: 
For the operation of any cathode ray tube intended 
for the display of visual images operating at an 
acceleration voltage exceeding 40 kV, authorization 
is required, or application of type approval 
(Bauartzulassung) and marking. 
Justification: German ministerial decree against 
ionizing radiation (Röntgenverordnung), in force 
since 2002-07-01, implementing the European 
Directive 96/29/EURATOM.  
NOTE Contact address: 
Physikalisch-Technische Bundesanstalt, 
Bundesallee 100, D-38116 Braunschweig, Tel.: 
Int+49-531-592-6320, Internet: http://www.ptb.de 
 N/A 
14 
 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
Justification: Ordinance (1990:944) on Prohibition 
in Connection with handling. Importation and 
exportation of Chemical Products (Certain Cases) 
 N/A 
 
Page 1 of 15 
Report No.: ACSCBAV13004 
 
  
 
 
 
 
 
ATTACHMENT 2 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
ZZ 
Australian Deviation (CB Bulletin data base April 26, 2010) 
- 
7.15 
Alternative to the method described in footnote f) 
 
N/A 
7.2 
Alternative to the method described in footnote h) 
 
N/A 
15.1.1 
Plugs for the connection of apparatus to mains-
powered socket-outlets shall comply with AS/NZS 
3112 or AS/NZS 3123. 
See appended table 14. 
(SB26 SUB) 
Pass 
15.3.5 
In Table 15, in the second and third rows of the first 
column replace ‘6’ with ‘7.5’ 
Detachable supply cord. 
(SB26 SUB) 
N/A 
16.2 
In Table 18, in the second and third rows of the first 
column replace ‘6’ with ‘7.5’. 
 Pass 
16.3 
A flexible cord complying with AS/NZS 3191 need 
not undergo this test. 
 N/A 
20.1.4 
In Table 21, in the third and fourth columns change 
both ‘HB75’ and ‘No requirement’ to ‘V-1’. 
 
Pass 
20.201 
Resistance to fire - Alternative tests 
 
N/A 
20.201.1 
General – “Parts of non-metalic material” 
 
N/A 
 
a) Exemption for components contained in an 
enclosure of material V-0 to AS/NZS 60695.11.10 
with openings not exceeding 1 mm in width 
No PIS. 
N/A 
 
b) Exemption for small components as defined in 
20.201.1 
 N/A 
20.201.2 Tests 
N/A 
20.201.2.1  Testing of non-metalic parts 
 
N/A 
 
Part of non-metallic material shall be subject to the 
glow-wire test of AS/NZS 60695.2.11 
which shall be carried out at 550°C. 
 
N/A 
20.201.2.2  Testing of insulated parts 
 
N/A 
 
Part of insulating material supporting 
POTENTIAL 
IGNITION SOURCES 
shall be subject to the glow wire 
test of AS/NZS 60695.2.11 which shall be carried 
out at 750°C. 
The test shall be also carried out on other parts of 
insulating material which are within a 
distance of 3 mm of the connection. 
 N/A 
 
For parts which withstand the glow-wire test but 
produce a flame, other parts above the 
connection within the envelope of a vertical cylinder 
having a diameter of 20 mm and a height of 50 mm 
shall be subjected to the needle-flame test. 
However, parts shielded by a barrier 
which meets the needle-flame test need not be 
tested. 
The needle-flame test shall be made in accordance 
with AS/NZS 4695.2.2 with the following 
modifications:  Clause of AS/NZS 4695.2.2 
(“5/Severities”, “8/Test procedure”, 
 “10/Evaluation of test results”) 
 N/A 