Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
6 HAZARDOUS 
RADIATION 
Pass 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h) 
No ionizing radiation 
N/A 
6.1 
EN 60065 
European Council Directive 96/29/Euratom of 13 
May 1996 10cm from outer surface of apparatus 
<1µSv/h (0,1mR/h) 
No ionizing radiation 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1  .... : Class 1 
Pass 
 
Emission limits under fault conditions .................... : Laser Optical Pickup:Class 1 
Pass 
 
HEATING UNDER NORMAL OPERATING CONDITIONS 
Pass 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
(see appended table) 
Pass 
7.1.1 
Temperature rise of accessible parts 
(see appended table) 
Pass 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
(see appended table) 
Pass 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
(see appended table) 
Pass 
7.1.4 
Temperature rise of windings 
(see appended table) 
Pass 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
(see appended table) 
Pass 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
No such supporting parts 
N/A 
 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
Pass 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
PCB, windings 
Pass 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
Tools are required 
Pass 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
No hygroscopic material used 
Pass 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
Tools are required 
Pass 
8.5 
Class I equipment 
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N/A 
 
Resistors bridging basic insulation complying with 
14.2.1 a) 
 N/A 
 
 
page 6 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
8.6 
Class II equipment and Class II constructions 
within Class I equipment 
 Pass 
 
Reinforced or double insulation between 
hazardous live parts and accessible parts 
 Pass 
 
Components bridging reinforced or double 
insulation complying with 14.1 a) or 14.3 
T501, T502 
Pass 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
2 capacitors in series complying with 14.2.1 a) 
 N/A 
 
Reinforced or double insulation being bridged with 
a single capacitor complying with 14.2.1 b) 
CY1, CY2, CY501, CY502 
Pass 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N/A 
8.7 
Basic insulation between parts at 35 V to 71 V 
(peak) a.c. or 60 V to 120 V d.c. and accessible 
parts 
No such voltage 
N/A 
 
Reinforced or double insulation between circuits 
operating at voltages between 35 V and 71 V 
(peak) a.c. or between 60 V and 120 V d.c. and 
hazardous live parts at higher voltage 
 N/A 
 
Separation by Class II isolating transformer 
 
N/A 
 
Separation by Class I transformer 
 
N/A 
 
Separation by earthed conductive part 
 
N/A 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) :  
N/A 
 
Reinforced insulation > 0,4 mm (mm) .................... : T501 bobbin:> 0.8mm 
T502 bobbin: >0.8mm 
Optocoupler U502, U504, 
U505: 0.40mm 
Enclosure (front panel): 
>1.5mm 
Separation sheet on internal 
enclosure under power board: 
0.51mm. 
Pass 
 
Thin sheet insulation 
Inside T501, T502 
Pass 
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3 
Withstand 2120Vp test. 
Pass 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3 
 N/A 
 
Reinforced insulation, two layers each of which 
meet 10.3 
 N/A 
 
 
page 7 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
Reinforced insulation, three layers any two which 
meet 10.3 
Withstand 4240Vp test. 
Pass 
8.9 
Adequate insulation between internal hazardous 
live conductors and accessible parts 
           
N/A 
 
Adequate insulation between internal hazardous 
live parts and conductors connected to accessible 
parts 
           
N/A 
8.10 
Double insulation between conductors connected 
to the mains and accessible parts 
Live wires are double 
insulated, no secondary wire 
can come closer to live parts 
Pass 
8.11 
Detaching of wires 
      
N/A 
 
No undue reduction of creepages or clearance 
distances if wires become detached 
Mating lock connector used for 
mains. No risk of detached. 
N/A 
 Vibration 
test carried out  ........................................ : No, see above 
N/A 
8.12 
Adequate cross-sectional area of internal wiring to 
mains socket-outlets 
 N/A 
8.13 
Adequate fastening of windows, lenses, lamp 
covers etc. (pull test 20 N for 10 s) 
 Pass 
8.14 
Adequate fastening of covers (pull test 50 N for 
10 s) 
 Pass 
8.15 
No risk of damage to the insulation of internal 
wiring due to hot parts or sharp edges 
Internal wires secured and 
keep enough distance from 
sharp or hot parts. 
Pass 
8.16 
Only special supply equipment can be used 
 N/A 
8.17 
Insulated winding wire without additional 
interleaved insulation 
 N/A 
8.18 
Endurance test as required by 8.17 
 
N/A 
8.19 
Disconnection from the mains 
 
Pass 
8.19.1 
Disconnect device 
Mains plug or appliance 
coupler. 
Pass 
 
All-pole switch or circuit breaker with >3mm 
contact separation 
Not used as a disconnect 
device 
N/A 
8.19.2 
Mains switch ON indication 
Not used as a disconnect 
device 
N/A 
8.20 
Switch not fitted in the mains cord 
 
Pass 
8.21 
Bridging components comply with clause 14 
 
N/A 
 
 
page 8 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS 
Pass 
9.1 
Testing on the outside 
Pass 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
No such high voltage 
N/A 
9.1.1.1 
Touch current measured from terminal devices 
using the network in annex D ................................. :
U1<8.0Vp  
U2<0.10Vp 
Pass 
 
Discharge not exceeding 45 Μc <1μC Pass 
 
Energy of discharge not exceeding 350 Mj 
No voltage exceeding 15Kv 
N/A 
9.1.1.2 
Test with test finger and test probe 
 Pass 
9.1.2 
No hazardous live shafts of knobs, handles or 
levers 
 Pass 
9.1.3 
Ventilation holes and other holes tested by means 
of 4 mm x 100 mm test pin 
< 2 mm, no entering 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test 
pin (10 N); test probe D of IEC 61032 
 Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032 
 Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032 
No pre-set control 
N/A 
9.1.6 
No shock hazard due to stored charge on 
withdrawal of the mains plug; voltage (V) after 2 s  :
< 5V 
Pass 
 
If C is not greater than 0,1 Μf no test needed 
> 0.2 μF 
N/A 
9.1.7 
Enclosure sufficiently resistant to external force 
 Pass 
 
Test probe 11 of IEC 61032 for 10 s (50 N) 
 Pass 
 
Test hook of fig. 4 for 10 s (20 N) 
 
Pass 
 
30 mm diameter test tool for 5 s (100 or 250 N) .... : 100N Pass 
9.2 
No hazard after removing a cover by hand 
Can not be removed by hand 
N/A 
 
 
10 INSULATION 
REQUIREMENTS 
Pass 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation ................................................................. :
No antenna terminal. 
N/A 
10.2 Humidity 
treatment 48 h or 120 h ........................... : 120h, 40℃, 93%R.H. 
Pass 
10.3 
Insulation resistance and dielectric strength 
(See appended table) 
Pass 
 
 
Page of 73