Harman Kardon HS 300 (serv.man2) EMC - CB Certificate ▷ View online
page 29 of 69
Ref. No. : JSH006020709-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
(Cont)
Publication Date Title
EN/HD
Date
IEC 61051-2
1991
Varistors for use in electronic equipment
-
-
Part 2: Sectional specification for surge
suppression
varistors
IEC 61058-1
1996
Switches for appliances
-
12)
-
Part 1: General requirements
IEC/TR2 61149 1995
Guide for safe handling and operation of
-
-
mobile radio equipment
IEC 61260
1995
Electroacoustics - Octave-band and
EN 61260
1995
fractional-octave-band
filters
IEC 61293
1994
Marking of electrical equipment with
EN 61293
1994
ratings related to electrical supply - Safety
requirements
IEC 61558-1
1997
Safety of power transformers, power
EN 61558-1
1997
(mod)
supply units and similar
A1
1998
Part 1: General requirements and tests
A1
1998
IEC 61558-2-17 1997
Part 2-17: Particular requirements for
EN 61558-2-17 1997
transformers for switch mode power
supplies
IEC 61965
2000
Mechanical safety of cathode ray tubes
EN 61965
2001
IEC 62151
2000
Safety of equipment electrically connected
-
-
to a telecommunication network
IEC Guide 104 1997
The preparation of safety publications
-
and the use of basic safety publications
and group safety publications
ISO 262
1973
ISO general purpose metric screw threads
-
-
- Selected sizes for screws, bolts and nuts
ISO 306
1994
Plastics - Thermoplastic materials -
-
-
Determination of Vicat softening
temperature
(VST)
ISO 7000
1989
Graphical symbols for use on equipment -
-
-
Index and synopsis
ITU-T
1988
Tests on power-fed repeaters using
-
-
Recommendation
solid-state devices in order to check the
K.17
arrangements for protection from
external
interference
ITU-T
1996
Resistibility of subscriber's terminal to
-
-
Recommendation
overvoltages and overcurrents
K.21
———————
12) IEC 61058-1:2000 + A1:2001, mod., are harmonized as EN 61058-1:2002.
Noted
page 30 of 69
Ref. No. : JSH006020709-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Annex ZB
(normative)
Special national conditions
(normative)
Special national conditions
Special national condition: National characteristic or practice that cannot be changed even over a long
period, e.g. climatic conditions, electrical earthing conditions. If it affects harmonization, it forms part of the
European Standard or Harmonization Document.
For the countries in which the relevant special national condition apply these provisions are normative, for
other countries they are informative.
period, e.g. climatic conditions, electrical earthing conditions. If it affects harmonization, it forms part of the
European Standard or Harmonization Document.
For the countries in which the relevant special national condition apply these provisions are normative, for
other countries they are informative.
2.6.1
Denmark
The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish
socketoutlets
Justification:
Heavy Current Regulations, Section 107
The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish
socketoutlets
Justification:
Heavy Current Regulations, Section 107
Class II
N/A
13.3.1
Norway
To the second paragraph the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral
is not provided
To the second paragraph the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral
is not provided
Pass
page 31 of 69
Ref. No. : JSH006020709-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
15.1.1
Denmark
To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-
D1.
Appliances of CLASS I provided with socket-
outlets with earth contact or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with the Heavy Current Regulations,
Section 107-2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall have the following dimensions:
See EN 60065:2002
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket
outlets. Shutters are not required
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall
be in compliance with HeavyCurrent Regulations
Section 107-2-D1, Standard sheet DK 1-3a, DK
1-5a or DK 1-7a
Justification
To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding
13 A shall be provided with a plug according to
the Heavy Current Regulations Section 107-2-
D1.
Appliances of CLASS I provided with socket-
outlets with earth contact or which are intended
to be used in locations where protection against
indirect contact is required according to the
wiring rules shall be provided with a plug in
accordance with the Heavy Current Regulations,
Section 107-2-D1 standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for providing power to
CLASS II apparatus with a rated current of 2,5 A
shall have the following dimensions:
See EN 60065:2002
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket
outlets. Shutters are not required
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall
be in compliance with HeavyCurrent Regulations
Section 107-2-D1, Standard sheet DK 1-3a, DK
1-5a or DK 1-7a
Justification
:
Heavy Current Regulations, Section 107
Pass
15.1.1
Ireland
Apparatus which is fitted with a flexible cable or
cord shall be provided with a plug in accordance
with Statutory Instrument 525: 1997, “13 A Plugs
and Conversion Adapters for Domestic Use
Regulations: 1997.
Justification
Apparatus which is fitted with a flexible cable or
cord shall be provided with a plug in accordance
with Statutory Instrument 525: 1997, “13 A Plugs
and Conversion Adapters for Domestic Use
Regulations: 1997.
Justification
:
SI 525: 1997
Pass
page 32 of 69
Ref. No. : JSH006020709-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
15.1.1
Norway
Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as applicable, with
the following amendments:
§ 8 Dimensions
a 2,5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply
with the enclosed Standard Sheet I.
See EN 60065:2002
Other dimensions according to CEE Publication 7
Standard Sheet I "Portable Single-Way Socket-
Outlets".
§ 24 Mechanical strength
a 2,5 A, 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification
Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as far as applicable, with
the following amendments:
§ 8 Dimensions
a 2,5 A 250 V two-pole socket-outlets for
electronic apparatus shall comply
with the enclosed Standard Sheet I.
See EN 60065:2002
Other dimensions according to CEE Publication 7
Standard Sheet I "Portable Single-Way Socket-
Outlets".
§ 24 Mechanical strength
a 2,5 A, 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification
:
Act of 24 May 1929 relating to supervision of
electrical installation
(TEA 1929/FEL 1998).
electrical installation
(TEA 1929/FEL 1998).
No mains socket-outlet.
N/A
15.1.1
United Kingdom
Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a "standard plug" in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a "standard plug" in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
NOTE "Standard plug" is defined in SI 1768:1994 and
essentially means an approved plug
conforming to BS 1363 or an approved conversion plug.
Justification
:
SI 1768: 1994
Pass
J.2
Norway
After Table J.1 the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral
is not provided
After Table J.1 the following is added:
In Norway, due to the IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230 V in case of a single earth
fault.
Justification:
Based on a use in Norway of an IT power
distribution system where the neutral
is not provided
Pass