Harman Kardon HS 300 (serv.man2) EMC - CB Certificate ▷ View online

 
 
page 21 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
19 
STABILITY AND MECHANICAL HAZARDS 
Pass 
 
Mass of the equipment exceeding 7 kg  ................. : 5.3kg 
N/A 
 
Apparatus intended to be fastened in place – 
suitable instructions 
No 
N/A 
19.1 
Test on a plane, inclined at 10
o
 to the horizontal 
 
N/A 
19.2 
100 N force applied vertically downwards 
 
N/A 
19.3 
Apparatus mass > 25 kg or height > 1 M or 
supplied with cart or stand 
 N/A 
19.4 
Edges or corners not hazardous 
 
Pass 
19.5 
Glass surfaces with an area exceeding 0,1 m² or 
maximum dimension > 450 mm, pass the test of 
19.5.1 
No glass surface 
N/A 
19.6 
Wall or ceiling mountings adequate 
Not for wall or ceiling mounting 
N/A 
 
20 
RESISTANCE TO FIRE 
Pass 
20.1 
Electrical components and mechanical parts 
Pass 
 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60707 with 
openings not exceeding 1 mm in width 
 N/A 
 
b) Exemption for small components as defined in 
20.1 
See components list 
Pass 
20.1.1 Electrical 
components 
meet the requirements of 
Clause 14 or 20.1.4 
See components list 
Pass 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 Kv or leaving an internal fire enclosure, not 
contributing to the spread of fire 
No voltage exceeding 4Kv 
N/A 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
V-1 or better to IEC60707, unless used in a fire 
enclosure 
Rated: V-0 
Pass 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage >400 V 
(peak) a.c. or d.c. meets V-0 to IEC 60707 
Rated: V-0 
Pass 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 21 comply with the relevant 
flammability category in Table 21 
See components list 
Pass 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 21 and fig. 13 
 
N/A 
 
 
page 22 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
20.2 Fire 
enclosure 
 
N/A 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 Kv (peak) a.c. or d.c. contained in a fire 
enclosure to V-1 
 
N/A 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 N/A 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
           
N/A 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
N/A 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
IP20 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 
N/A 
A.10.2.2 Humidity 
treatment carried out for 7 days 
 
N/A 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
N/A 
 
Complies with IEC 62151 clause 1 
Not to be connected to the 
telecommunication networks 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard 
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
 
N/A 
 
Complies with IEC 62151 clause 6  
 
N/A 
 
Complies with IEC 62151 clause 7  
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
 
N/A 
 
CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND 
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60065:2002) 
Noted 
 
 
page 23 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
3.1 
Add the following indent at the end of the list: 
- exposure to excessive sound pressures from 
headphones or earphones. 
 
NOTE A new method of measurement is described in EN 
50332-1, Sound system equipment: 
Headphones and earphones associated with portable audio 
equipment - Maximum sound pressurelevel measurement 
methodology and limit considerations - Part 1: General 
method for "one package equipment”, and in EN 50332-2, 
Sound system equipment: Headphones and earphones 
associated with portable audio equipment - Maximum sound 
pressure level measurement methodology and limit 
considerations - Part 2: Guidelines to associate sets with 
headphones coming from different manufacturers. 
 Noted 
4.1.1 
Replace the text of the note by: 
 
NOTE For ROUTINE TEST reference is made to EN 50333. 
 Noted 
 
5.1.i) 
Add the following note: 
 
NOTE For RATED POWER CONSUMPTION measurements 
of TVs reference is made to 
EN 60107. 
 Noted 
 
6.1 
Replace the entire subclause by: 
Apparatus including a potential source of ionizing 
radiation shall be so constructed that personal 
protection against ionizing radiation is provided 
under normal operating conditions and under 
fault conditions. 
 
Compliance is checked by measurement under 
the following conditions
In addition to the normal operating conditions, all 
controls adjustable from the outside BY HAND, 
by any object such as a tool or a coin, and those 
internal adjustments or pre-sets which are not 
locked in a reliable manner, are adjusted so as to 
give maximum radiation whilst maintaining an 
intelligible picture for 1 h, at the end of which the 
measurement is made. 
 
NOTE Soldered joints and paint lockings are examples of 
adequate locking. 
 Noted 
 
 
page 24 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
6.1 
(Cont) 
The amount of ionizing radiation is regulated by 
European Council Directive 96/29/Euratom of 13 
May 1996. This directive requires that at any 
point 10 cm from the outer surface of the 
apparatus, the dose-rate shall not exceed 
1µSv/h (0,1 mR/h) taking account of the 
background level. 
Moreover, the measurement shall be made under 
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is 
maintained for 1 h, at the end of which the 
measurement is made. 
A picture is considered to be intelligible if the 
following conditions are met: 
- a scanning amplitude of at least 70 % of the 
usable screen width; 
- a minimum luminance of 50 cd/m² with locked 
blank raster provided by a test generator; 
- a horizontal resolution corresponding to at least 
1,5 MHz in the centre, with a similar vertical 
degradation; 
- not more than one flashover per 5 min. 
 Noted 
13.3.1 
Delete note 4. 
 
Noted 
14 
Delete note 4 and note 5. 
 
Noted  
15.1.1 
Delete note 1 and note 2. 
 
Noted  
15.2 
Delete note 2. 
 
Noted  
16.1 
Delete note 1. 
 
Noted  
16.2 
Delete the note. 
 
Noted  
20 
Delete note 2. 
 
Noted  
Annex B 
Replace note 1 by: 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
 Noted 
 
Annex G 
Delete the note. 
 
Noted  
Annex J.2  Delete the notes of Table J.1 
 
Noted  
Annex N 
Add after the introduction: 
For ROUTINE TEST reference is made to EN 
50333. 
 Noted 
 
Page of 73