DOWNLOAD Harman Kardon HS 300 (serv.man2) Service Manual ↓ Size: 3.78 MB | Pages: 73 in PDF or view online for FREE

Model
HS 300 (serv.man2)
Pages
73
Size
3.78 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-300-sm2.pdf
Date

Harman Kardon HS 300 (serv.man2) EMC - CB Certificate ▷ View online

 
 
page 9 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
11 FAULT 
CONDITIONS 
Pass 
11.1 
No shock hazard under fault condition 
           
Pass 
11.2 
Heating under fault condition 
(See appended table) 
Pass 
 
No hazard from softening solder 
 
Pass 
11.2.1 
Measurement of temperature rises 
 
Pass 
11.2.2 
Temperature rise of accessible parts 
 
Pass 
11.2.3 
Temperature rise of parts, other than windings, 
providing electrical insulation 
(See appended table) 
Pass 
 
Temperature rise of printed circuit boards (PCB) 
exceeding the limits of table 3 by max. 100 K for 
max. 5 min 
 N/A 
 
a) Temperature rise of printed circuit boards (PCB) 
to 20.1.3, exceeding the limits of table 3 by not 
more than 100 K for an area not greater than 2 cm²
 N/A 
 
b) Temperature rise of printed circuit boards (PCB) 
to 20.1.3 up to 300 K for an area not greater than 
2 cm² for a maximum of 5 min 
 N/A 
 
Meets all the special conditions if conductors on 
printed circuit boards are interrupted 
           
N/A 
 
Class I protective earthing maintained 
 
N/A 
11.2.4 
Temperature rise of parts acting as a support or 
mechanical barrier 
           
Pass 
11.2.5 
Temperature rise of windings 
(see appended table) 
Pass 
11.2.6 
Temperature rise of parts not subject to the limits 
of 11.2.1 to 11.2.5 
(see appended table) 
Pass 
 
12 MECHANICAL 
STRENGTH 
Pass 
12.1.1 
Bump test where mass >7 kg 
5.3kg 
N/A 
12.1.2 Vibration 
test 
Not carried out, no connection 
which might impair safety can 
become loosen 
Pass 
12.1.3 
Impact hammer test 
0.5J Pass 
 
Steel ball test 
2J Pass 
12.1.4 
Drop test for portable apparatus where mass < 7 
kg 
 Pass 
12.1.5 
Thermoplastic enclosures strain relief test 
70
o
C, 7h 
Pass 
12.2 
Fixing of knobs, push buttons, keys and levers 
 Pass 
12.3 
Remote controls with hazardous live parts 
 
N/A 
 
 
page 10 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
12.4 
Drawers (pull test 50 N, 10 s) 
 
Pass 
12.5 
Antenna coaxial sockets providing isolation 
 
N/A 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
Pass 
13.1 
Clearances in accordance with 13.3 
 
Pass 
 
Creepage distances in accordance with 13.4 
  
Pass 
13.2 
Determination of operating voltage 
T501: pin13, 14, 15- pin 5, 6: 
270Vrms, 500Vp 
T502: pin3 - pin 15: 380Vrms, 
580Vp 
Pass 
13.3 Clearances 
Primary (operating voltage: 
240Vrms) —accessible parts / 
enclosure: 4.0mm required 
Primary (operating voltage: 
270Vrms, 500Vp) —accessible 
parts / enclosure: 4.2mm 
required 
Primary (operating voltage: 
380Vrms, 580Vp) —accessible 
parts / enclosure: 5.1mm 
required 
Primary heat sink —accessible 
parts / enclosure: 5.1mm 
required 
L-N before fuse link:  
2.0mm required 
T501: P—S: 4.2mm required 
T502: P—S: 5.1mm required
 
Pass 
 
 
page 11 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9 
Measured distance:  
Primary (operating voltage: 
240Vrms) —accessible parts / 
enclosure: >4.5mm  
Primary (operating voltage: 
270Vrms, 500Vp) —accessible 
parts / enclosure: >6.5mm  
Primary (operating voltage: 
380Vrms, 580Vp) —accessible 
parts / enclosure: >10mm  
Primary heat sink —accessible 
parts / enclosure: >10mm 
L-N before fuse link: 3.7mm 
T501: P—S: >6.5mm  
T502: P—S: >8.0mm  
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Such circuits are secondary 
circuit and do not include 
hazardous voltage, no basic, 
supplementary or reinforced 
insulation required. 
N/A 
13.4 Creepage 
distances 
Primary (operating voltage: 
240Vrms) —accessible parts / 
enclosure: 5.0mm required 
Primary (operating voltage: 
270Vrms, 500Vp) —accessible 
parts / enclosure: 5.6mm 
required 
Primary (operating voltage: 
380Vrms, 580Vp) —accessible 
parts / enclosure: 7.7mm 
required 
Primary heat sink —accessible 
parts / enclosure: 7.7mm 
required 
L-N before fuse link: 3.0mm 
required 
T501: P—S: 5.6mm required 
T502: P—S: 7.7mm required 
Pass 
 
 
page 12 of  69 
Ref. No. : JSH006020709-002 
 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
Creepage distances greater than table 11 minima  Measured distance:  
Primary (operating voltage: 
240Vrms) —accessible parts / 
enclosure: >5.5mm 
Primary (operating voltage: 
270Vrms, 500Vp) —accessible 
parts / enclosure: >6.5mm 
Primary (operating voltage: 
380Vrms, 580Vp) —accessible 
parts / enclosure: >10mm 
Primary heat sink —accessible 
parts / enclosure: >10mm 
L-N before fuse link: 3.7mm  
T501: P—S: >6.5mm  
T502: P—S: >8.0mm 
Pass 
13.5 Printed 
boards 
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12 
No such parts 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
No such parts 
N/A 
 
 
14 COMPONENTS 
Pass 
14.1 Resistors 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
No such components 
N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
b) Resistors separately approved .......................... :
 
N/A 
Page of 73
Display