Harman Kardon HS 300 (serv.man2) EMC - CB Certificate ▷ View online
page 9 of 69
Ref. No. : JSH006020709-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
11 FAULT
CONDITIONS
Pass
11.1
No shock hazard under fault condition
Pass
11.2
Heating under fault condition
(See appended table)
Pass
No hazard from softening solder
Pass
11.2.1
Measurement of temperature rises
Pass
11.2.2
Temperature rise of accessible parts
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(See appended table)
Pass
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards (PCB)
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
to 20.1.3, exceeding the limits of table 3 by not
more than 100 K for an area not greater than 2 cm²
N/A
b) Temperature rise of printed circuit boards (PCB)
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
to 20.1.3 up to 300 K for an area not greater than
2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
Pass
11.2.5
Temperature rise of windings
(see appended table)
Pass
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table)
Pass
12 MECHANICAL
STRENGTH
Pass
12.1.1
Bump test where mass >7 kg
5.3kg
N/A
12.1.2 Vibration
test
Not carried out, no connection
which might impair safety can
become loosen
which might impair safety can
become loosen
Pass
12.1.3
Impact hammer test
0.5J Pass
Steel ball test
2J Pass
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
Pass
12.1.5
Thermoplastic enclosures strain relief test
70
o
C, 7h
Pass
12.2
Fixing of knobs, push buttons, keys and levers
Pass
12.3
Remote controls with hazardous live parts
N/A
page 10 of 69
Ref. No. : JSH006020709-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
12.4
Drawers (pull test 50 N, 10 s)
Pass
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
Pass
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
T501: pin13, 14, 15- pin 5, 6:
270Vrms, 500Vp
270Vrms, 500Vp
T502: pin3 - pin 15: 380Vrms,
580Vp
580Vp
Pass
13.3 Clearances
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: 4.0mm required
240Vrms) —accessible parts /
enclosure: 4.0mm required
Primary (operating voltage:
270Vrms, 500Vp) —accessible
parts / enclosure: 4.2mm
required
270Vrms, 500Vp) —accessible
parts / enclosure: 4.2mm
required
Primary (operating voltage:
380Vrms, 580Vp) —accessible
parts / enclosure: 5.1mm
required
380Vrms, 580Vp) —accessible
parts / enclosure: 5.1mm
required
Primary heat sink —accessible
parts / enclosure: 5.1mm
required
parts / enclosure: 5.1mm
required
L-N before fuse link:
2.0mm required
T501: P—S: 4.2mm required
T502: P—S: 5.1mm required
Pass
page 11 of 69
Ref. No. : JSH006020709-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
comply with table 8 and, where applicable, table 9
Measured distance:
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: >4.5mm
240Vrms) —accessible parts /
enclosure: >4.5mm
Primary (operating voltage:
270Vrms, 500Vp) —accessible
parts / enclosure: >6.5mm
270Vrms, 500Vp) —accessible
parts / enclosure: >6.5mm
Primary (operating voltage:
380Vrms, 580Vp) —accessible
parts / enclosure: >10mm
380Vrms, 580Vp) —accessible
parts / enclosure: >10mm
Primary heat sink —accessible
parts / enclosure: >10mm
parts / enclosure: >10mm
L-N before fuse link: 3.7mm
T501: P—S: >6.5mm
T502: P—S: >8.0mm
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N/A
13.4 Creepage
distances
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: 5.0mm required
240Vrms) —accessible parts /
enclosure: 5.0mm required
Primary (operating voltage:
270Vrms, 500Vp) —accessible
parts / enclosure: 5.6mm
required
270Vrms, 500Vp) —accessible
parts / enclosure: 5.6mm
required
Primary (operating voltage:
380Vrms, 580Vp) —accessible
parts / enclosure: 7.7mm
required
380Vrms, 580Vp) —accessible
parts / enclosure: 7.7mm
required
Primary heat sink —accessible
parts / enclosure: 7.7mm
required
parts / enclosure: 7.7mm
required
L-N before fuse link: 3.0mm
required
required
T501: P—S: 5.6mm required
T502: P—S: 7.7mm required
Pass
page 12 of 69
Ref. No. : JSH006020709-002
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
Creepage distances greater than table 11 minima Measured distance:
Primary (operating voltage:
240Vrms) —accessible parts /
enclosure: >5.5mm
240Vrms) —accessible parts /
enclosure: >5.5mm
Primary (operating voltage:
270Vrms, 500Vp) —accessible
parts / enclosure: >6.5mm
270Vrms, 500Vp) —accessible
parts / enclosure: >6.5mm
Primary (operating voltage:
380Vrms, 580Vp) —accessible
parts / enclosure: >10mm
380Vrms, 580Vp) —accessible
parts / enclosure: >10mm
Primary heat sink —accessible
parts / enclosure: >10mm
parts / enclosure: >10mm
L-N before fuse link: 3.7mm
T501: P—S: >6.5mm
T502: P—S: >8.0mm
Pass
13.5 Printed
boards
N/A
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
not conductively connected to the mains:
clearances and creepage distances as in table 12
No such parts
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
No such parts
N/A
14 COMPONENTS
Pass
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such components
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
b) Resistors separately approved .......................... :
N/A
Click on the first or last page to see other HS 300 (serv.man2) service manuals if exist.