page 45 of  69 
Ref. No. : JSH006020709-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
 
 
 
National differences for CHINA 
(According to CB bulletin No. 109A. These differences are taken from 
IEC60065:1993 and adopted to IEC 60065:2001.)
 
Pass 
 
IEC 60065 sub-clause 4.2.2: Test voltage is 0.9 
times or 1.06 times rated voltage of the 
equipment; GB8898 sub-clause 4.2.2: Test 
voltage is 0.9 times or 1.1 times rated voltage of 
the equipment, which of the equipment used in 
China shall cover 220V±10%, 50Hz. 
 Pass 
 
IEC standard for plug is IEC 60083; The Chinese 
national standard for Plugs is GB1002-1996, 
which is not equivalent with IEC 60083 
 Pass 
 
 
 
National differences for KOREA 
(According to CB bulletin No. 109A. These differences are taken from 
IEC60065:1998 and adopted to IEC 60065:2001.)
 
Pass 
5.101 
Other marking ; Wording "____ “ or an 
information regulated in IEC Publication 417 
giving high voltage warning to layman shall 
be marked, if an apparatus contains a part more 
than 600volts. 
 N/A 
15.1.1 
Plugs for the connection of the apparatus to the 
supply mains and socket outlets for providing 
mains power to other apparatus shall 
comply with the Korean requirements (KSC8300 
and 8305). 
 Pass 
31 
Radio frequency interference 
The apparatus shall comply with the relevant 
CISPR requirements.(EMC = EMI + EMS) 
 Pass 
 
 
National differences for SINGAPORE 
(According to CB bulletin No. 109A. These differences are taken from 
IEC60065:1993 and adopted to IEC 60065:2001.)
 
Pass 
 
Throughout the standard, whenever the words "white pine board" appear, insert 
the words "or plywood board" to it. 
Noted 
 
SS 143 Amendment No.1 and No. 2 
 
4.1.3 
Delete "45 % to 75 %" and insert "65 _ 5 %". 
75% maximum in IEC 
60065:2001 
Noted 
7.1 
Resistance to heat without external forces 
Adopt the temperature specified for the tropical 
conditions. 
 Pass 
8.6 
(9.3.4)* 
Delete the note "A Quality Assessment System 
for capacitors complying with Subclause 14.2 is 
under consideration in the IEC". 
This is not in IEC 60065:2001. 
Noted 
 
 
page 46 of  69 
Ref. No. : JSH006020709-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
10.2 
Humidity treatment 
Adopt the testing conditions designed for tropical 
conditions. 
120h at a relative humidity of 
93%, ambient temperature 
40
o
Pass 
16 
External flexible cords 
Delete "IEC Publication 227: Polyvinyl Cloride 
Insulated Cables of Rated Voltages up to and 
Including 450/750 V and IEC Publication 245: 
Rubber Insulated Cables of Rated Voltage up to 
and including 450/750V" and insert "Singapore 
Standard 236: Flexible Cords", whenever they 
appear in this clause. 
Delete "CEE Publication 13, CEE Publication 2 
and IEC Publication 173: Colours of the Cores of 
Flexible Cables and Cords" whenever they 
appear in this clause. 
 Noted 
16.2 
Delete the notes in small print and insert "A 
nominal cross-sectional area of 0.75 mm
2
 will 
satisfy this requirement". 
 Noted 
16.3b 
(16.4b)* 
Delete "Subclause 3.1 of IEC Publication 227-2: 
Part 2: Test Methods" and insert "Subclause 9.1 
of SS 236": 
9.1 Flexing Test (except for tinsel cords, twisted 
twin and single core cords). 
The test shall be carried out by mieans of the 
apparatus shown in Figure 5. This apparatus has 
a carrier C supporting two pulleys A and B 
arranged so that the cord is horizontal between 
the pulleys. The carrier moves backward and 
forward over a distance of 1 m at an 
approximately constant speed of 0.33 m/s. 
A sample of flexible cord fabout 5 m long shall be 
stretched over the pulleys as shown in the figure, 
each end being loaded with a weight. The weight 
and the diameter of the pulleys A and B shall be 
as given in Table 1. 
Screene cords in accordance with Table 7 shall 
be tested before application of the screen and 
outer sheath. 
The pulleys shall have a semi-circular shaped 
groove for circular cords and a flat groove for 
parallel twin cords. The 
restraining clamps D shall be fixed so that the pull 
is always applied by the weight from which the 
carrier is mowing away. The carrier shall make 30 
000 backward and forward movements (60 000 
single strokes). Each conductor of the sample 
shall be loaded with the current specified in Table 
2. 
For twin cords and for light PVC-sheated 3-core 
cords, the voltage between the conductors shall 
be approximately 230 V a.c. For all other cords 
 Noted 
 
 
page 47 of  69 
Ref. No. : JSH006020709-002 
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
having three or more cores a three-phase a.c. 
voltage of about 400 V shall be applied to three 
conductors, any additional conductors being 
connected to the neutral. 
During the test no open-circuit in any core or 
short-circuit between cores shall occur. 
After the test, any sheath on cords having three 
or more cores shall be removed. The cord, or the 
laid up cores, shall then withstand the voltage 
test specified in Subclause 8.2. or 8.3 as 
appropriate, but with a test voltage not exceeding 
2000 V. 
TABLE 1, TABLE 2, FIGURES 4 and 5, see the 
CB bulletin. 
*In parenthesis: clauses according to IEC60065:1993. 
 
 
 
 
 
National differences MALAYSIA, according to CB bulletin No. 109A 
IEC 60065, 7th ed.
 
Pass 
 
The supply voltage in Malaysia is 240 Vac, at 
50Hz. 
 Pass 
 
Class 0 and 01 appliances are not allowed 
 Pass 
 
13A fused plug-tops shall comply to Malaysian 
standard (MS 589:Part1:1997), if applicable. 
Same as BS1363 type. 
Pass 
 
2-pin plug tops shall comply to Malaysian 
standard (MS 1578:2003) if applicable 
 N/A 
 
 
 
 
 
 
 
 
 
 
 
page 48 of  69 
Ref. No. : JSH006020709-002 
Remarks 
 
 
 
 
External views of EUT 
 
 
 
 
 
 
 
 
 
 
Page of 73