Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
NO: marking to state equipment must be
connected to an earthed mains socket-outlet
connected to an earthed mains socket-outlet
N
SE: marking required on equipment connected to
a telecommunication network, where separation
between the mains and the network relies on
connection to protective earth
a telecommunication network, where separation
between the mains and the network relies on
connection to protective earth
N
SE: marking to state equipment must be
connected to an earthed mains socket-outlet
connected to an earthed mains socket-outlet
N
B.8.1
DK: method b) of 8.1 is permitted only for
permanently connected equipment
permanently connected equipment
N
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
N
B.14.12
DK: surge suppressors between
telecommunications network and accessible parts
permitted only for permanently connected
equipment
telecommunications network and accessible parts
permitted only for permanently connected
equipment
N
NO: surge suppressors between TNV circuits and
accessible parts of Class
accessible parts of Class
Ι equipment permitted
only if the equipment is marked stating it must be
connected to an earthed mains socket-outlet
connected to an earthed mains socket-outlet
N
SE: surge suppressors between TNV circuits and
accessible parts of Class
accessible parts of Class
Ι equipment permitted
only if the equipment is marked stating it must be
connected to an earthed mains socket-outlet, the
marking text is: "Apparaten skall anslutas till jordat
uttag"
connected to an earthed mains socket-outlet, the
marking text is: "Apparaten skall anslutas till jordat
uttag"
N
page 30 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
ZC
ANNEX ZC TO EN 60065, A-DEVIATIONS
5
DE: additional markings required in German language:
N
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
N
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N
IT: certification number on the back cover
N
6.1
DE: ionizing radiation from TV receivers not
exceeding 1
exceeding 1
µSv/h (= 7.2 pA/kg = 0.1 mR/h) at
10 cm
N
page 31 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
National differences KOREA
IEC 60065, 6
th
edition
CB Bulletin 103A / KR 02 I
5.101 Addition
Other marking;
Wording “ “ ( See the CB Bulletine) or an
information regulated in IEC Publication 60417
giving high voltage warning to layman shall be
marked, if an apparatus contains a part more
than 600 volts.
information regulated in IEC Publication 60417
giving high voltage warning to layman shall be
marked, if an apparatus contains a part more
than 600 volts.
N
15.1.1 Replacement:
Plugs for the connection of the apparatus to the
supply mains and socket outlets for providing
mains power to other apparatus shall comply with
the Korean requirements (KSC 8300 and 8305).
supply mains and socket outlets for providing
mains power to other apparatus shall comply with
the Korean requirements (KSC 8300 and 8305).
P
31 Radio
frequency
Interference
The apparatus shall comply with the relevant
CISPR requirements. (EMC=EMI + EMS)
CISPR requirements. (EMC=EMI + EMS)
Not
checked
401597