Harman Kardon HKTS 7 (serv.man2) EMC - CB Certificate ▷ View online
page 25 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14
TABLE: list of critical components and materials
P
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity
Mains
Transformer
Transtec
TT0869803320
AC 230-240V
IEC 60065
—
Thermal link
Joint Force
M33
2A, 250V,
130
°C
IEC 60691
TÜV
Mains Fuse
Walter
TSD
T1.25AL 250V
IEC 60127
Mains
fuseholder
Chin Shin
(Walter)
R3-11
10A 250V
IEC 60065
—
IEC 61058-1
Mains switch
Rong Feng Ind.
Co., Ltd
RF-1003 10(4)
8/80A,
250V Class II
IEC60065:98
Annex G
NEMKO
Plug
I Sheng
SP-021A
2.5A 250V
CEE 7
Cord
H03VVH2-F
2 x 0.75mm²
IEC 60227
For UK:
Plug with fuse
Luen Tai
Electric
9518
13A 250V
BS 1363
BSI
Cord Rhythm
Wire
Ind. Co., Ltd.
H03VVH2-F
2 x 0.75mm²
IEC 60227
KEMA
For Korea:
Plug
Volex
MP2217
3A 250V
KS C8305
Cord
VCTFK
2 x 0.75mm²
KS C3304
Transformer
Bobbin
EI Dupont de
Nemours
Nylon 66
101,101F
94V-2 Complies
with
FH 3-40mm/min
IEC 60707:81
—
Mains fuse
holder
holder
Walter
R3-11
Min. FV 1
IEC 60707
—
Sec. connector
P103
JWT
A3963Wv2-5P
Min. FV 1
IEC 60707
—
Plastic
Enclosure
Enclosure
Shin-bo Plastic
Molding Corp
PA-764
Min. FV 1
IEC 60707
—
PCB Jian
He
(Cheng Ho)
FR-1
Min. FV 1
IEC 60707
—
Alternative
Hsiang Kuo
FR-1 or FR-4
page 26 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
GROUP DIFFERENCES (COMMON MODIFICATIONS) TO IEC 60065
CONTENTS
Add the following annexes:
Annex ZA (normative) Other international
publications quoted in this standard with the
references of the relevant European publications.
(See the standard EN 60065:1998)
publications quoted in this standard with the
references of the relevant European publications.
(See the standard EN 60065:1998)
Annex ZB (normative) Special national conditions
Annex ZC (informative) A-deviations
Noted
1.1.1
Replace the text of note 1 by:
NOTE 1 This standard can be used as a guide for
the testing of battery operated apparatus.
the testing of battery operated apparatus.
Noted
3.1 Delete
the
note.
Add the following indent:
-
Exposure to excessive sound pressures from
headphones or earphones
headphones or earphones
NOTE A new method is under consideration by
CENELEC/TC 206
CENELEC/TC 206
Noted
15.1.1
Delete notes 1 and 2.
Add to note 4:
Attention is drawn to the fact that a standard is
under preparation (presently prEN 50074) for
socket-outlets which allow connection of Class II
appliances only.
under preparation (presently prEN 50074) for
socket-outlets which allow connection of Class II
appliances only.
Noted
15.2
Delete note 2.
Noted
16.1
Delete note 1.
Noted
16.2 Delete
the
note.
Noted
20
Delete note 2.
Noted
Annex B
Delete note 2.
Noted
B.5.4.1e)
Delete notes 1 and 2.
Noted
B.8.1
Delete notes 1, 2 and 3.
Noted
B.8.2 Delete
the
note.
Noted
B.14.12
Delete notes 1 and 2.
Noted
Annex G
Delete the note.
Noted
page 27 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
Annex P
Bibliography
Add the following notes for the standards
indicated:
indicated:
IEC 60130
NOTE: IEC 60130-9:1989 +
A1: 1993 are harmonized as EN
60130-9
(not
modified).
IEC 60169
NOTE: Parts 23, 24 and25 are
harmonized as Ens (not modified)
IEC 60173
NOTE: Harmonized as HD 27
S1: 1983 (not modified).
IEC 60260
NOTE: Harmonized as HD 98
S1: 1977 (not modified).
IEC 60335-2-56 NOTE: Harmonized as EN 60335-
2-56:1997 (not modified).
IEC 61040
NOTE: Harmonized as EN
61040:1992 (not modified).
IEC 60695
NOTE: Harmonized as EN 60695
series
(not
modified).
Noted
page 28 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class
Ι apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
earthing continuity when inserted in Danish socket-
outlets
N
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
P
DK: Class
Ι equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
N
DK: socket-outlets for providing power to Class
ΙΙ
equipment with a rated current of 2.5 A shall have
dimensions according to the drawing on page 131
of EN 60065:98 other dimensions shall be to
IEC 60083 Standard Sheet C 1a for portable
socket-outlets
dimensions according to the drawing on page 131
of EN 60065:98 other dimensions shall be to
IEC 60083 Standard Sheet C 1a for portable
socket-outlets
N
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
N
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
P
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
P
NO: mains socket-outlets on Class
ΙΙ equipment meet CEE Publication 7 with the
following amendments:
N
- dimensions 2.5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60065:98
comply with Standard Sheet 1 page 132 of
EN 60065:98
N
- mechanical strength 2.5 A, 250 V socket-outlets
tested as specified in EN 60065, 12.1.3
tested as specified in EN 60065, 12.1.3
N
- protecting rim also tested
N
B.5.4.1
NO: marking required for equipment connected to
a communications network other than the public
telecommunications network, where separation
between the mains and the network relies upon a
safety earth connection
a communications network other than the public
telecommunications network, where separation
between the mains and the network relies upon a
safety earth connection
N