DOWNLOAD Harman Kardon HKTS 7 (serv.man2) Service Manual ↓ Size: 1.42 MB | Pages: 40 in PDF or view online for FREE

Model
HKTS 7 (serv.man2)
Pages
40
Size
1.42 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hkts-7-sm2.pdf
Date

Harman Kardon HKTS 7 (serv.man2) EMC - CB Certificate ▷ View online

 
 
page 17 of 31 
Ref.No.:401597  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
17 
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS 
 
17.1 
Torque test to Table 12: 
 
- screws into metal: 5 times 
 
 
- screws into non-metallic material: 10 times 
 
17.2 Correct 
introduction 
into female threads in non-
metallic material 
 P 
17.3 
Cover fixing screws: captive 
 
 
Non-captive fixing screws: no hazard when 
replaced by a screw whose length is 10 times its 
diameter 
 P 
17.4 
No loosening of conductive parts carrying a current 
> 0.2 A 
 N 
17.5 
Contact pressure not transmitted through plastic 
other than ceramic for connections carrying a 
current > 0.2 A 
 N 
17.6 
Stranded conductors of flexible supply cords 
carrying a current > 0.2 A with screw terminals not 
consolidated by solder 
 N 
17.7 
Cover fixing devices other than screws have 
adequate strength and their positioning is 
unambiguous 
 N 
17.8 
Fixing devices for detachable legs or stands 
provided 
 N 
17.9 
Internal pluggable connections, affecting safety, 
unlikely to become disconnected 
 P 
 
18 
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION AGAINST 
THE EFFECTS OF IMPLOSION 
 
18.1 
Picture tube separately approved  ......................... :   
 
Picture tubes > 16 cm intrinsically protected 
 
 
Non-intrinsically protected tubes > 16 cm used 
with protective screen 
 N 
18.2 
Intrinsically protected tubes: tests on 12 samples 
 
18.2.1 
Samples subject to ageing: 6 
 
18.2.2 
Samples subject to implosion test: 6 
 
18.2.3 
Samples subject to mechanical strength test (steel 
ball): 6 
 N 
18.3 
Non-intrinsically protected tubes tested to 18.3 
 
 
 
page 18 of 31 
Ref.No.:401597  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
19 
STABILITY AND MECHANICAL HAZARDS 
 
 
Mass of the equipment exceeding 18 kg  .............. :  <18 kg 
Noted 
19.1 
Test on a plane, inclined at 10º to the horizontal 
 
19.2 
100 N applied vertically downwards 
 
19.3 
Smooth edges and corners 
 
19.4 
Glass surfaces with an area exceeding 0.1 m
2
 or 
maximum dimension > 450 mm, pass the test of 
19.4.1 
 N 
 
20 RESISTANCE 
TO 
FIRE 
 
20.1 
Electrical components and mechanical parts 
 
 
a) Exemption for components contained in an 
enclosure of material FV 0 to IEC 60707 with 
openings not exceeding 1 mm in width 
 N 
 
b) Exemption for small components as defined in 
20.1 
Close-end connector 
20.1.1 
Electrical components meet the requirements of 
14.2.5, 14.4, 14.5.3, 14.6.6 or 20.1.4 
 P 
20.1.2 
Insulation of internal wiring working at voltages 
> 4 kV or leaving an internal fire enclosure, not 
contributing to the spread of fire 
 N 
20.1.3 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 
between 50 V and 400 V (peak) a.c. or d.c. meets 
FV 1 or better to IEC 60707, unless used in a fire 
enclosure 
PCB 
(see list of crit. components 
and materials) 
 
Material of printed circuit boards on which the 
available power exceeds 15 W at a voltage 400 V 
(peak) a.c. or d.c. meets FV 0 to IEC 60707 
 N 
20.1.4 
Components and parts not covered by 20.1.1, 
20.1.2 and 20.1.3 (other than fire enclosures) 
mounted nearer to a potential ignition source than 
the distances in Table 13 comply with the relevant 
flammability category in Table 13 
Bobbin; Plastic enclosure; 
Fuse holder; Mains switch; 
Switch and Fuse holder tubing; 
Sec. connector P103. 
(see list of critical components 
and materials) 
 
Components and parts as above but shielded from 
a potential ignition source, with the barrier area in 
accordance with Table 13 and fig. 13 
 N 
 
 
page 19 of 31 
Ref.No.:401597  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
20.2 
Fire enclosure 
20.2.1 
Potential ignition sources with open circuit voltage 
> 4 kV (peak) a.c. or d.c. contained in a fire 
enclosure to FV 1 
 N 
20.2.2 
Internal fire enclosures with openings not 
exceeding 1 mm in width and with openings for 
wires completely filled 
 N 
20.2.3 
Requirements of 20.2.1 and 20.2.2 met by an 
internal fire enclosure 
 N 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
 N 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 N 
A.10.2.2 
Humidity treatment carried out for 7 days 
 
 
 
 
page 20 of 31 
Ref.No.:401597  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
B.5.4.1 
e) Where the separation of TNV circuits from other 
circuits relies on protective earthing the 
instructions make it clear that protective earthing is 
essential 
 N 
B.8.1 
TNV circuits separated from the mains circuit and from hazardous live parts by 
either: 
 
a) double or reinforced insulation 
 
 
b) basic insulation with earthed protective 
screening 
 N 
B.8.2 
TNV circuits separated from circuits other than 
those in B.8.1 and from accessible conductive 
parts by basic insulation meeting the requirements 
for clearances and creepage distances for the 
voltages concerned 
 N 
B.9.1.1 
TNV circuit terminals contacts which cannot be 
touched by probe B.1, exempt from the 
requirements inaccessible terminal contacts in 
9.1.1 
 N 
B.10.1 
Insulation between TNV terminals and antenna 
terminals (including interconnection terminals 
which may be connected to equipment with 
antenna terminals) withstands the 50 discharges of 
10.1 
 N 
B.14.12 
Surge suppressors between TNV circuits and 
other parts of the equipment have breakdown 
voltage at least 1.8 times the mains voltage 
 N 
 
 
Page of 40
Display