DOWNLOAD Harman Kardon HKTS 7 (serv.man2) Service Manual ↓ Size: 1.42 MB | Pages: 40 in PDF or view online for FREE

Model
HKTS 7 (serv.man2)
Pages
40
Size
1.42 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hkts-7-sm2.pdf
Date

Harman Kardon HKTS 7 (serv.man2) EMC - CB Certificate ▷ View online

 
 
page 21 of 31 
Ref.No.:401597  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
 
 
 
Position of the functional switch (W)  ..................... : 0 W in 0FF-position 
 
Operating conditions 
254.4V, 1/8 of the max. non-clipping output power using the pink noise signal acc. to 4.1.6 .  
Input signal connected to ’Line Level in L/R’  
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
                254.4 
0.43 
79 
21 
 
Loudspeaker impedance (
Ω) ................................ : 4Ω 
 
 Several 
loudspeaker 
systems 
 
 
Marking of loudspeaker terminals 
High Level  in/out 
 
monitored point: 
dT (K) 
Permitted dT (K) 
Supply wiring insulation (Not under mechanical stress.) 
27 
60 
Mains switch  
26 
60 
Mains fuse 
19 
60 
Iron core mains transformer.  
51 
— 
Transformer support (rubber) 
51 
60 
PCB 63 
85 
Buttons (plastic) 
18 
50 
Enclosure (wood) 
24 
60 
Enclosure (metal) near knobs. 
38 
40 
Heat Sink, external (metal) 
40 
40 
Knobs (plastic) 
18 
50 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 21 
 
 
Ambient temperature t2 (
°C) ................................. : 22 
 
temperature rise dT of winding: 
R
1
 (
Ω) 
R
2
 (
Ω) 
dT (K) 
permitted 
dT (K) 
insulation 
class 
Transformer Primary winding 
9.267 
11.498 
61 
85 
Transformer Secondary winding (Yellow) 
0.701 
0.855 
55 
85 
Transformer Secondary winding (Red) 
1.252 
1.528 
55 
85 
 
 
 
page 22 of 31 
Ref.No.:401597  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
7.2 
TABLE: softening temperature of thermoplastics 
temperature T of part 
T - normal  
conditions (ºC) 
T - fault  
conditions (ºC) 
T softening 
(ºC) 
Prim. Fuse holder 
<150 
<150 
202 
 
10.3 
TABLE: insulation resistance measurements 
insulation resistance R between: 
R (M
Ω) 
required R (M
Ω) 
Between the poles of the circuit directly connected to the 
supply mains. 
>10 Min.2 
Reinforced insulation. 
>10 
Min.4 
 
10.3 TABLE: 
electric 
strength 
measurements 
test voltage applied between: 
test voltage (V) 
Breakdown 
Between the poles of the circuit directly connected to the 
supply mains. 
2120V peak 
No 
Reinforced insulation. 
4240V peak 
No 
 
 
 
 
page 23 of 31 
Ref.No.:401597  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
11.2 
TABLE: summary of fault condition tests 
 
Voltage (V) 0.9 or 1.06 times rated voltage  .......... : 220-240 
 
 
Ambient temperature (
°C) ..................................... : 22 
 
 
Winding temperature rise measurements 
 
 
Ambient temperature t1 (ºC)  ................................. : 22 
 
 
Ambient temperature t2 (ºC)  ................................. : 22 
 
No
Component 
No. 
Fault  Test voltage
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
1 Max. 
non-
clipping 
output 
power  
(pink noise) 
-- 254.4  4h 
Mains 
fuse 
0.55 
Pn= 104W, In= 0.55A. 
Transf. prim. winding dT = 78K 
Transf. sec. windings dT = 68-
72K 
Enclosure (metal) = 44K 
Heat sink (exterior) = 48K 
No remarks. 
2 Q105  sc  254.4  --  Mains 
fuse 
>2.6A 
Q107 and Q108 broke, mains 
fuse opened immediately. 
No remarks. 
3 Q107  sc  254.4  --  Mains 
fuse 
>2.6A 
Q107 and Q108 broke, mains 
fuse opened immediately. 
No remarks. 
4 C133  sc  198 
--  Mains 
fuse 
>2.6A 
Mains fuse opened immediately. 
No remarks. 
5 D115 
(  -  ) 
sc 198  -- 
Mains 
fuse 
>2.6A 
Mains fuse opened immediately. 
No remarks. 
6 D110 
(  -  ) 
sc 198  -- 
Mains 
fuse 
>2.6A 
Mains fuse opened immediately. 
No remarks. 
 
 
page 24 of 31 
Ref.No.:401597  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
No
Component 
No. 
Fault  Test voltage
 (V) 
Test  
time 
Fuse No.
Fuse  
current 
(A) 
Result 
7 C122  sc  198  3min. 
Mains 
fuse 
≤2.5A  Pn = 525-0W, In = 2.5-0A  
After 2min. conductors on the 
PCB were interrupted, rectifier 
D110 broke and mains fuse 
opened.  
  
No remarks. 
(See next fault case)  
8 C122  sc  198 
3s Mains 
fuse 
3.4A 
Pn = 640W, In = 3.4A. 
Interrupted conductors were 
bridged and mains fuse replaced 
with T2.5AL: 
Original fuse T1.25AL considered 
opened due to the high In; test 
aborted after 3s.   
No remarks. 
Page of 40