Harman Kardon HKTS 7 (serv.man2) EMC - CB Certificate ▷ View online
page 9 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
11.2.5
Temperature rise of windings
P
11.2.6
Temperature rise of other parts not subject to the
limits of 11.2.1 to 11.2.5
limits of 11.2.1 to 11.2.5
P
12 MECHANICAL
STRENGTH
12.1.1 Bump
test
P
12.1.2
Vibration test
No connection or part which
might impair safety can
become loose
might impair safety can
become loose
P
12.1.3 Impact
test
P
12.2
Fixing of knobs, push buttons, keys and levers
P
12.3
Remote controls with hazardous live parts
N
12.4
Drawers (pull test 50 N, 10 s)
N
12.5
Antenna coaxial sockets providing isolation
N
13
CLEARANCES AND CREEPAGE DISTANCES
13.1
Clearances and creepage distances in accordance
with 13.2 (fig. 9); minimum distance ..................... :
with 13.2 (fig. 9); minimum distance ..................... :
Prim.-acc.metal parts: 13mm
P
13.1.1
Reduction applied if the 3 conditions are met ....... :
N
Reduction applied for Grade 2 winding wire ......... :
N
13.1.2
Use of cemented joints .......................................... :
N
Tests to confirm cemented joints
N
13.2
Clearances and creepage distances of parts of
different polarity connected to the mains, as in
fig. 9; minimum distance ....................................... :
different polarity connected to the mains, as in
fig. 9; minimum distance ....................................... :
3.8mm P
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N
13.3
Enclosed, enveloped or hermetically sealed parts:
clearances and creepage distances to Table 4
clearances and creepage distances to Table 4
N
13.4
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N
13.5
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N
page 10 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14 COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N
a) Resistors separately approved ......................... : No
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N
b) Resistors separately approved ......................... : No
N
14.2
Capacitors and RC units
Capacitors separately approved
N
14.2.1
Y capacitors tested to IEC 60384-14, 2:nd Edition :
N
14.2.2
X capacitors tested to IEC 60384-14, 2:nd Edition :
N
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................... :
connected to the mains: tests for X2 ..................... :
N
14.2.5
Capacitors with volume exceeding 1750 mm
3
where short-circuit current exceeds 0.2 A:
compliance with IEC 60384-1, 4.38 category B or
better ..................................................................... :
compliance with IEC 60384-1, 4.38 category B or
better ..................................................................... :
N
Capacitors with volume exceeding 1750 mm
3
,
mounted closer to a potential ignition source than
Table 5 permits: compliance with IEC 60384-1,
4.38 category B or better ....................................... :
Table 5 permits: compliance with IEC 60384-1,
4.38 category B or better ....................................... :
N
Shielded by a barrier to FV 0 or metal .................. :
N
14.3
Inductors and windings
14.3.1
Transformers and inductors marked with
manufacturer’s name and type ............................. :
manufacturer’s name and type ............................. :
Transtec TT0869803320
P
Transformers and inductors separately approved : No
N
14.3.2
Isolating transformer complies with 14.3.3,
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
14.3.4.1 or 14.3.4.2 and 14.3.5.1 or 14.3.5.2 …….:
14.3.3, 14.3.4.2 and 14.3.5.2
P
Separating transformer complies with 14.3.3,
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
14.3.4.3 and 14.3.5.1 or 14.3.5.2 …….……………:
N
Flammability test of insulating material acc. to
20.1.4 (except in thin sheet form)
20.1.4 (except in thin sheet form)
P
14.3.3.1
Clearances and creepage distances according to
clause 13
clause 13
P
14.3.3.2
Transformers meet the constructional
requirements
requirements
P
page 11 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.3.4.1
Class
ΙΙ transformers have adequate separation
between hazardous live windings and accessible
windings (double or reinforced insulation)
windings (double or reinforced insulation)
Prim.-sec: 9.2mm
P
Coil formers and partition walls
≥ 0.4 mm
1.3mm P
14.3.4.2
Class
Ι transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
14.3.4.2 are met
N
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N
14.3.5.1
Class
ΙΙ transformers have adequate insulation
between hazardous live windings and accessible
parts (double or reinforced insulation)
parts (double or reinforced insulation)
Prim.-iron core: 6.2mm
P
Coil formers and partition walls
≥ 0.4 mm
1.3mm P
14.3.5.2
Class
Ι transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N
14.4
High voltage components
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N
Component meets category FV 1 of IEC 60707
N
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N
14.5
Protective devices
Protective devices used within their ratings
P
External clearance and creepage distances
appropriate for the voltage across the device when
opened
appropriate for the voltage across the device when
opened
P
14.5.1.1
a) Thermal cut-outs separately approved
N
b) Thermal cut-outs tested as part of the
submission
submission
N
14.5.1.2
a) Thermal links separately approved
P
b) Thermal links tested as part of the submission
N
14.5.1.3
Thermal devices resettable by soldering
N
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
IEC 60127
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ... : Fuse T1.25A L 250V
P
page 12 of 31
Ref.No.:401597
IEC 60065
Clause
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
14.5.2.3
Not possible to connect fuses in parallel ............... :
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ........ :
replacing fuse-links without the use of a tool ........ :
Tools are required
P
14.5.3
PTC-S thermistors comply with IEC 60738
N
PTC-S devices (15 W) category FV 1 or better
N
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
and their position is correctly marked
N
14.6
Switches
(See appended table)
14.6.1 Permanently
connected
equipment
provided
with
an all-pole mains switch unless 5.4.2 is met
N
14.6.2
Manually operated mechanical switch (MOMS),
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
required where power consumption > 15 W and/or
peak voltage > 4 kV; MOMS required ................... :
Yes
P
Switch readily accessible and not in mains cord
On the rear side. *)
P
Exception
for
automatic
switching
N
Exception for continuous operation
N
14.6.3
Manually operated mechanical switch (MOMS):
switch indication On position clearly discernible
switch indication On position clearly discernible
P
Indication by marking meets Cl. 5
POWER
P
Indication
of
the
OFF
position
P
14.6.4
Manually operated mechanical switch (MOMS)
fitted, is there a Stand-by mode ............................ :
fitted, is there a Stand-by mode ............................ :
No Noted
Stand-by mode clearly discernible ........................ :
N
Exception for low Stand-by current < 0.7 mA
(peak)
(peak)
N
14.6.5
Components bridging contacts of mains switches
comply with 14.1 a) or 14.2.2
comply with 14.1 a) or 14.2.2
N
14.6.6
Manually operated mechanical switches (MOMS)
separately approved to IEC 61058-1
separately approved to IEC 61058-1
P
Manually operated mechanical switch (MOMS)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
tested as part of the equipment complies with
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8
and/or 14.6.9 and Annex G (G1.1)
N
*) Accepted for this product group.
Click on the first or last page to see other HKTS 7 (serv.man2) service manuals if exist.