Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate ▷ View online
Page 80 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
9.1.1.1
For Class I constructions the r.m.s. touch current to
earth is not more than 3.5 MIU
earth is not more than 3.5 MIU
Class II equipment
N/A
9.1.1.1a
For audio signals of professional and commercial
apparatus, 120 V r.m.s.
apparatus, 120 V r.m.s.
N/A
For audio signals other than professional and
commercial apparatus, 71 V r.m.s.
commercial apparatus, 71 V r.m.s.
P
9.1.1.1b
Touch current carried out in accordance with UL 101
with the measuring instrument described in Annex D
does not exceed 0.5 MIU. Delete Note 2.
with the measuring instrument described in Annex D
does not exceed 0.5 MIU. Delete Note 2.
Suitable instrument used,
see table 9.1.1
P
9.1.1.2
UL articulated finger (figure 14) used instead of the
test probe B (IEC 61032)
test probe B (IEC 61032)
P
Reference to test probes 18 and 19 of IEC 61032 are
deleted
deleted
N/A
10
Table 5, Note 1: With respect to mains voltages in
the range of 105-130 V (r.m.s.), the test voltages are
considered to be 1414 V peak for basic and
supplementary insulation and 2828 V peak for
reinforced insulation
the range of 105-130 V (r.m.s.), the test voltages are
considered to be 1414 V peak for basic and
supplementary insulation and 2828 V peak for
reinforced insulation
P
11
Component power supplies and their power
transformers complying with UL 1310, UL 1950 3rd
Ed., or UL 60950 are considered to fulfill the clause
transformers complying with UL 1310, UL 1950 3rd
Ed., or UL 60950 are considered to fulfill the clause
N/A
11.1
The permissible touch current for terminal contacts
increased to twice the value given in 9.1.1.1.
increased to twice the value given in 9.1.1.1.
See table 11.1
P
11.2.1
Additional fuse testing is not required if the
temperature is limited by fuses
temperature is limited by fuses
P
12
Component power supply adaptors and their
enclosures complying with UL 1310, UL 1950 3rd
Ed., or UL 60950 are deemed to fulfill the clause
enclosures complying with UL 1310, UL 1950 3rd
Ed., or UL 60950 are deemed to fulfill the clause
N/A
12.1.3
Impact test uses the 50 mm steel sphere only
P
Table 6 - Impact test criteria detailing impact
location, impact energy and additional pass/fail
results applied according to UL 60065
location, impact energy and additional pass/fail
results applied according to UL 60065
P
12.1.4
As an alternative, any number from one to three
samples are permitted to be used in any combination
that results in a total of three drops
samples are permitted to be used in any combination
that results in a total of three drops
N/A
12.1.6
Handle strength test. When polymeric materials are
involved, testing is to be conducted before and after
the sub-clause 12.1.5 stress relief test.
involved, testing is to be conducted before and after
the sub-clause 12.1.5 stress relief test.
N/A
12.8
Test for enclosures, barriers, components and leads
that rely on adhesive
that rely on adhesive
N/A
Page 81 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
13
Component power supplies and their power
transformers complying with UL 1310, UL 1950 3
transformers complying with UL 1310, UL 1950 3
rd
Ed., or UL 60950 are deemed to fulfill the clause
N/A
13.4
The material group is verified according to UL 746A Material group IIIb used
N/A
Reference to the IEC 60112 PTI test is deleted
No such printed boards
N/A
13.5.1
Reference to IEC 60249-2 is replaced by UL 796
No such printed boards
N/A
13.5.2
Coated printed wiring boards comply with UL 746C
N/A
14
Annex Y and additional component requirements
applied according to UL 60065
applied according to UL 60065
P
14.1
Component power supplies and their resistors
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause
N/A
14.2
Component power supplies and their capacitors
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause.
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause.
N/A
14.2.1
As an alternative, a component such as a capacitor,
a combination capacitor and resistor, or a
suppressor may comply with UL 1414.
a combination capacitor and resistor, or a
suppressor may comply with UL 1414.
UL approved components
used
used
(see appended table 14)
P
14.2.2
As an alternative, a capacitor, a combination
capacitor and resistor, or a varistor, or a suppressor
may comply with UL 1414.
capacitor and resistor, or a varistor, or a suppressor
may comply with UL 1414.
UL approved components
used
used
(see appended table 14)
P
14.2.4
Components subjected to the requirements in 14.2.1
and 14.2.2 also comply with UL 1414 enclosure
requirements
and 14.2.2 also comply with UL 1414 enclosure
requirements
N/A
14.3
Component power supplies and their inductors and
windings complying with UL 1310, UL 1950 3
windings complying with UL 1310, UL 1950 3
rd
Ed.,
or UL 60950 are considered to fulfill the clause
N/A
14.4
High voltage materials are rated V-2 minimum
N/A
14.4.1
High voltage arcing test replaces the High voltage
transformers and multipliers test
transformers and multipliers test
N/A
14.4.2
Deleted
N/A
14.4.3
High voltage component part flame test
N/A
14.4.4
High voltage isolating component test
N/A
14.5.1.1
Thermal cut-outs comply with UL 873, UL 8730-2-9
or UL 60730-2-9
or UL 60730-2-9
N/A
14.5.1.2
Thermal links comply with UL 60691
N/A
Page 82 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
14.5.1.3
Deleted
N/A
14.5.2.1
Fuse links comply with UL 248-14
P
14.5.2.2
Reference to IEC 60127 is deleted
P
Pre-arcing time/current characteristic and breaking
capacity marking requirements are deleted
capacity marking requirements are deleted
N/A
14.5.3
As an alternative, a PTC thermistor may comply with
requirements of UL 1434
requirements of UL 1434
N/A
14.5.4
Reference to fuse-links is deleted
N/A
Other protective devices directly connected to the
mains have adequate breaking capacity and comply
with UL 873, UL 1416, UL 1417 or UL 2111
mains have adequate breaking capacity and comply
with UL 873, UL 1416, UL 1417 or UL 2111
N/A
14.6.1
Switches and relays comply with UL 1054, UL
61058-1 or UL 508
61058-1 or UL 508
Approved switch used and
located on the rear
enclosure
located on the rear
enclosure
(see appended table 14)
P
Mains switch or relay are rated for the total rated
current consumption of the apparatus
current consumption of the apparatus
P
Rating of a mains switch or relay in audio apparatus
intended for commercial use
intended for commercial use
N/A
14.6.2 - .4 Deleted
N/A
14.6.5
A switch or relay that controls a mains socket-outlet
have a rating equal to the rated current consumption
of the apparatus plus the current rating of the socket-
outlet
have a rating equal to the rated current consumption
of the apparatus plus the current rating of the socket-
outlet
N/A
14.6.6
Mains switches comply with (a), (b) or (c)
Approved switch comply
with (c) used
with (c) used
P
Mains relay contacts comply with (a), (b) or (d)
N/A
A switch that controls a mains receptacle complies
with (b) and a relay that controls a mains receptacle
complies with (b) or (d)
with (b) and a relay that controls a mains receptacle
complies with (b) or (d)
N/A
14.6.6a
Switch or relay contacts have current rating equal to
or greater than 1.414 times the inrush current of the
apparatus
or greater than 1.414 times the inrush current of the
apparatus
N/A
14.6.6b
Switch or relay is TV rated
N/A
14.6.6c
Switch is located on the back of apparatus and is not
operable from a remote control
operable from a remote control
P
14.6.6d
Relay subjected to the Relay Endurance Test
N/A
Page 83 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
14.6.6.1
Peak inrush current test
N/A
14.6.6.2
Relay endurance test
N/A
14.6.7
Double pole switch controlling a.c. and d.c. circuits
N/A
14.7
The jointed test finger (Fig 14) is used to determine
accessibility and operation of the interlock
accessibility and operation of the interlock
N/A
14.10.1
Internal rechargeable and non-rechargeable
batteries that are replaceable by the user or skilled
persons additionally comply with 14.10.2
batteries that are replaceable by the user or skilled
persons additionally comply with 14.10.2
– 14.10.5.
N/A
Test requirements from UL 2054 added for special
battery packs that are removable by the user from
the apparatus (Short circuit, Abnormal charging,
Forced-discharge, and 250-N steady force tests may
be carried separately from the apparatus)
battery packs that are removable by the user from
the apparatus (Short circuit, Abnormal charging,
Forced-discharge, and 250-N steady force tests may
be carried separately from the apparatus)
N/A
Note: Consumer grade, non-rechargeable carbon-
zinc or alkaline batteries are not subjected to the
tests specified in Clauses 14.10.2
zinc or alkaline batteries are not subjected to the
tests specified in Clauses 14.10.2
– 14.10.5.
N/A
14.10.5
Alternatively, one sample subjected to three drops
N/A
14.10.6
Location of overcurrent protective device ............. :
N/A
Alternatively, the overcurrent protective device in the
apparatus battery-supply circuit is not required if the
apparatus is to be connected to a vehicle power
outlet via UL 2089 vehicle battery adapter
apparatus battery-supply circuit is not required if the
apparatus is to be connected to a vehicle power
outlet via UL 2089 vehicle battery adapter
N/A
14.11
Component power supplies and their optocouplers
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause.
complying with UL 1310, UL 1950 Third Edition, or
UL 60950 are considered to fulfill the clause.
N/A
Optocouplers comply with UL 1577
N/A
Optocouplers bridging reinforced insulation comply
with requirements for double protection as specified
in UL 1577
with requirements for double protection as specified
in UL 1577
N/A
External clearances and creepage distances of
optocouplers comply with 13.1
optocouplers comply with 13.1
N/A
14.12
Reference to IEC 61051-2 replaced by UL 1449
N/A
Reference to IEC 60707 replaced by UL 94
N/A
All references to IEC 60151 are deleted
N/A
15.1.1
Attachment plug current rating (no less than 125% of
the current drawn under normal operating conditions)
and voltage rating ................................................ :
the current drawn under normal operating conditions)
and voltage rating ................................................ :
Plug rated 10A for
equipment rated <3A
equipment rated <3A
P