CAUTION
BEFORE SERVICING THE UNIT,READ THE “SAFETY
PRECAUTIONS” IN THIS MANUAL.
MODEL:GR-349/389SQF
REFRIGERATOR
SERVICE MANUAL
3 OLP (OVER LOAD PROTECTOR)
1) Definition of OLP
(1) OLP (OVER LOAD PROTECTOR) is attached to the
Hermetic Compressor and protects the Motor by cutting
off current in Compressor Motor in case of over-rising
temperature by Bimetal in the OLP.
(2) When over-voltage flows to Compressor motor, the
Bimetal works by heating the heater inside the OLP, 
and the OLP protects Motor by cutting off current which
flows to the Compressor Motor.
2) Role of the OLP
(1) The OLP is attached to the Hermetic Compressor used
for the Refrigerator and Show Case and prevents the
Motor Coil from being started in the Compressor.
(2) Do not turn the Adjust Screw of the OLP in any way for
normal operation of the OLP.
(Composition and connection Diagram of OLP)
CIRCUIT DIAGRAM
CONTACTING
POINT
COVER
BIMETAL
CONTACTING
POINT
HEATER
TERMINALS
ADJUST
SCREW
HEATER
BIMETAL
Figure  20
NOTE : 1. This is a basic diagram and specifications vary in different localities.
- 10 -
C
N
L
3
6
5
2
S
BK
PK
RD
BL
BL
BL
BK
BL
CAPACITOR
PART
EARTH PART
COMPRESSOR
P.T.C
STARTER
RUNNING
BL
BL
BL
BK
PR
GN/YL
POWER
SUPPLY
CORD
RT-SENSOR
YL
BL
DEF-SENSOR
F-SENSOR
DOOR OPEN
PERCEPTION
BL
BL
BO
BO
GY
RD
GY PR BL YL
RD BN WH WH
BO
YL
BK
GY
BN
BK
OVERLOAD
PROTECTOR
STARTING
COOLING      
FAN MOTOR
DOOR SW-R
R-LAMP
M
C
M
FAN MOTOR
PWB ASSY, MAIN
DISPLAY CONTROL P.W.B
CIRCUIT DIAGRAM
1 2 3 4 5 6 7 8 9
GY
A
PR BL YL
RD BN WH WH
BO
1 2 3 4 5 6 7 8 9
¥ THE PLUG TYPE,
CAPACITOR PART,
COMPRESSOR EARTH
PART ON CIRCUIT
DIAGRAM ARE SUBJECT
TO CHANGE IN DIFFERENT
LOCALITIES AND ACCORDANCE
WITH MODEL TYPE
¥ WHEN STARTING CAPACITOR
IS NOT USED, NO.3,4 OF PTC
START IS CONNECTED
INTERNALLY
M
BK:BLACK
YL:YELLOW
SB:SKY BLUE
BN :BROWN
GN:GREEN
PK :PINK
RD:RED
BL :BLUE
GN/YL:GREEN/YELLOW
BO:BRIGHT ORANGE
PR:PURPLE
GY:GRAY
WH/BK:WHITE/BLACK
WH:WHITE
B
9 8 7 6
4 3 2 1
5
BL
YL
BK
GY
BN
BL
FUSE-M
( 72
ûC
)
SHEATH HEATER
GY
RD
B
A
3
854
JS8001B
1 COMPRESSOR AND ELECTRIC COMPONENTS
TROUBLESHOOTING (Mechanical Part)
- 11 -
YES
YES
YES
NO
YES
YES
NO
NO
5
YES
NO
YES
Power
Source.
Remove the PTC-
Starter from the
Compressor and
measure the voltage
between Terminal C of
Compressor and
Terminals 5 or 6 of PTC.
No Voltage.
(Rating Voltage
±10%)?
Replace OLP.
Reconnect.
Replace
PTC-Starter.
Replace OLP.
O.K.
Check connection
condition.
OLP disconnected?
Advise the customer
to use a regular
Trans.
Replace Compressor.
OLP works within
30 sec. in forcible
OLP operation by
turning instant power
on and off.
Components start in
the voltage of Rating
Voltage ±10% below.
Applied voltage isn't
in the range of Rating
Voltage ±10%.
Check the resistance
among M-C, S-C and
M-S in Motor
Compressor.
Check the resistance of
two terminals in PTC-
Starter.
Check if applying
a regular OLP.
Measure minimum
starting voltage after 5
min. for balancing cycle
pressure and cooling the
PTC.
Check the
resistance of
Motor
Compressor.
Check the
resistance of
PTC-Starter.
Check OLP.
Check
starting state.
1
2
3
4
5
1
5
5
4
3
5
5
2
2 PTC AND OLP
- 12 -
YES
NO
6
5
4
3
Normal operation of
Compressor is
impossible or poor.
Separate the PTC-Starter
from Compressor and
measure the resistance
between No. 5 and 6 (only
RSIR type) or No. 4 and 5 of
PTC-Starter with a Tester or
Whistone Bridge.
(Figure 21)
Separate the OLP from the
Compressor and check the
resistance value between
two terminals of OLP with
a Tester. (Figure 22)
Observation value is
220V/50Hz : 22
§
±30%
115V/60Hz : 6.8
§
±30%
240V/50Hz : 33
§
±30%
127, 220V/60Hz : 22
§
±30%
The resistance value is 0
or serveral hundreds 
§
.
The value is 
¡˜
.
Check another
electric components.
Replace OLP.
Check another
electric
components.
Replace
PTC-Starter.
Figure  21
Figure  22
Page of 60
Display

LG GR-389SQF Service Manual ▷ Download

  • DOWNLOAD LG GR-389SQF Service Manual ↓ Size: 3.59 MB | Pages: 60 in PDF or view online for FREE
  • Here you can View online or download the Service Manual for the LG GR-389SQF in PDF for free, which will help you to disassemble, recover, fix and repair LG GR-389SQF Refrigerator. Information contained in LG GR-389SQF Service Manual (repair manual) includes:
  • Disassembly, troubleshooting, maintenance, adjustment, installation and setup instructions.
  • Schematics, Circuit, Wiring and Block diagrams.
  • Printed wiring boards (PWB) and printed circuit boards (PCB).
  • Exploded View and Parts List.