Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate ▷ View online
Page 84 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
Configuration and electrical rating of an attachment
plug for apparatus for use on more than one supply
voltage by means of a voltage selector ................ :
plug for apparatus for use on more than one supply
voltage by means of a voltage selector ................ :
N/A
Polarized attachment plug
N/A
Wire gauge of conductors and internal wiring
connecting mains socket-outlets
connecting mains socket-outlets
N/A
15.1.3.1
Means of output connections on an audio amplifier
having an open-circuit audio output voltage not
limited to 120 V that is permanently connected to the
mains
having an open-circuit audio output voltage not
limited to 120 V that is permanently connected to the
mains
No such audio amplifier
N/A
Quick Connect Terminals:
N/A
a) Male tabs firmly mounted in place;
N/A
b) Mating female connectors provided with the
apparatus;
apparatus;
N/A
c) Strain Relief Test of Clause 16.5;
N/A
d) Installation instructions provided for assembly of
terminal to a conductor and strain relief
terminal to a conductor and strain relief
N/A
e) Terminals are appropriate for use with the size
and type of wire specified
and type of wire specified
N/A
15.1.3.2
Audio amplifiers having an audio output not limited to
120 V that are connected to the mains by a flexible
cord
120 V that are connected to the mains by a flexible
cord
N/A
15.2
Cross-sectional area of the earthing conductor in a
supply cord or in an interconnecting cable
supply cord or in an interconnecting cable
N/A
Earthing conductors may have green or green/yellow
insulation
insulation
N/A
15.3.5
Reference to IEC 60950 is replaced by Article 310 of
the National Electrical Code, ANSI/NFPA 70
the National Electrical Code, ANSI/NFPA 70
P
Table 15 - "AWG" replace mm² values
P
15.4
Component power supply adaptors complying with
UL 1310, UL 1950 Third Edition, or UL 60950 fulfill
the clause
UL 1310, UL 1950 Third Edition, or UL 60950 fulfill
the clause
N/A
16.1
Reference in the first paragraph to “sheathed”
flexible cords is deleted
flexible cords is deleted
(see appended table 14)
P
References to IEC 60227 and IEC 60245 deleted
P
Ampacity and VW-1 marking of mains supply flexible
cords ................................................................... :
cords ................................................................... :
NISPT-2 type used
Ampacity > 2A
Ampacity > 2A
P
Page 85 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
Table 17A - Cords for apparatus
P
16.2
Power supply cord earthing conductor size .......... :
Class II equipment
N/A
Reference to IEC 60950, Table 3B is replaced by
Article 400 of the National Electrical Code
Article 400 of the National Electrical Code
P
Table 18 - Upper current limit in column 1 increased
from 16 to 30 A and "AWG" wire sizes
from 16 to 30 A and "AWG" wire sizes
N/A
16.3
c) Flexible cords not complying with 16.1, used as
connection between the apparatus and other
apparatus are marked VW-1
connection between the apparatus and other
apparatus are marked VW-1
N/A
16.5
When polymeric materials are involved, strain and
twist testing is to be conducted before and after the
sub-clause 12.1.5 stress relief test.
twist testing is to be conducted before and after the
sub-clause 12.1.5 stress relief test.
P
17.8
Expanded to include all cart/stand parts supplied by
the manufacturer, such as casters and brackets.
Suitable assembly instructions are required.
the manufacturer, such as casters and brackets.
Suitable assembly instructions are required.
N/A
Relevant fixing means are not required when
installation is to be done by a skilled person
installation is to be done by a skilled person
N/A
17.10
Termination of aluminum conductors used as internal
wiring
wiring
N/A
17.11
An accessory was investigated to determine that: a).
The accessory and the combination of the accessory
and the apparatus presents no hazard in the sense
of this standard, and
b). The accessory is provided with installation
instructions.
The accessory and the combination of the accessory
and the apparatus presents no hazard in the sense
of this standard, and
b). The accessory is provided with installation
instructions.
N/A
17.11.1
Installation of an accessory by a skilled person:
a) The mechanical positioning is accomplished by
means of tools normally available or by means of
special tools provided as part of the installation kit,
a) The mechanical positioning is accomplished by
means of tools normally available or by means of
special tools provided as part of the installation kit,
N/A
b) The electrical connections are made by using
existing terminals and connections in the apparatus
or the building wiring
existing terminals and connections in the apparatus
or the building wiring
N/A
18
Non-intrinsically protected picture tubes comply with
18.1, 18.2.2 and 18.3. Intrinsically protected picture
tubes with a maximum face dimension exceeding 7.5
cm comply with UL 61965.
18.1, 18.2.2 and 18.3. Intrinsically protected picture
tubes with a maximum face dimension exceeding 7.5
cm comply with UL 61965.
N/A
A bulb of a picture tube having a face diameter of 7.5
cm or more are mounted in an enclosure
cm or more are mounted in an enclosure
N/A
Enclosure opening dimensions
N/A
Page 86 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
18.1
All tubes are mounted such that the enclosure of the
apparatus protects the tube against the effects of
implosion.
apparatus protects the tube against the effects of
implosion.
N/A
18.2
Clauses 18.2, 18.2.1 and 18.2.3 are deleted
N/A
19
The tests in 19.1, 19.2 and 19.3 do not cause the
apparatus to overturn.
apparatus to overturn.
See only clause 19.1 &
19.2.
19.2.
P
The test in 19.2.1 does not cause the apparatus to
slide
slide
N/A
When polymeric materials are involved, testing is to
be conducted before and after the sub-clause 12.1.5
stress relief test.
be conducted before and after the sub-clause 12.1.5
stress relief test.
N/A
19.1
References to an apparatus in combination with a
supplied cart or recommended stand are deleted
supplied cart or recommended stand are deleted
P
19.2
References to an apparatus in combination with a
supplied cart or recommended stand are deleted
supplied cart or recommended stand are deleted
P
19.2.1
Slide test
N/A
19.3
Horizontal force stability test using Table 20A values
from UL 60065
from UL 60065
N/A
19.5
Reference to the impact hammer in the first
compliance paragraph is deleted
compliance paragraph is deleted
N/A
19.6
Equipment rack mounting test
N/A
20.1a
Deleted
N/A
20.1b
Exception for parts such as protection TV lenses,
loudspeaker parts, external accessories, and fibrous
materials
loudspeaker parts, external accessories, and fibrous
materials
P
Reference to IEC 60707 replaced by UL 94
P
20.1.2
Sleeving, extruded tubing and insulation on wiring
are rated VW-1:
a) wiring located in a circuit that is considered a
potential ignition source, or
are rated VW-1:
a) wiring located in a circuit that is considered a
potential ignition source, or
UL listed material used
(see appended table 14)
P
b) wiring not located in a circuit that is a potential
ignition source but is in contact with wiring located in
a circuit that is a potential ignition source
ignition source but is in contact with wiring located in
a circuit that is a potential ignition source
P
20.1.2
Tape in contact with parts of circuits that are
potential ignition sources is flame retardant
potential ignition sources is flame retardant
P
Page 87 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
20.1.3
Printed wiring boards, on which the available power
as the connection exceeds 15 W or the operating
voltage exceeds 50 V a.c. or d.c under normal
operating conditions, are of flammability category V-
1 or better
as the connection exceeds 15 W or the operating
voltage exceeds 50 V a.c. or d.c under normal
operating conditions, are of flammability category V-
1 or better
UL listed printed wiring
boards with flammability of
V-0 used for power board
and V-1 used for other
board except power board
boards with flammability of
V-0 used for power board
and V-1 used for other
board except power board
(see appended table 14)
P
Reference to IEC 60707 replaced by UL 94
P
Exception for printed boards housed in metal
enclosures is deleted
enclosures is deleted
N/A
Option to use Clause G.1 of Annex G is deleted
N/A
20.1.4
Components and parts comply with the relevant
flammability category according to UL 94 as
specified in table 21
flammability category according to UL 94 as
specified in table 21
P
Component power supplies complying with UL1310,
UL1950 3rd Ed., or UL60950 fulfill the clause
UL1950 3rd Ed., or UL60950 fulfill the clause
N/A
Table 21 - Flammability categories for components
and parts
and parts
P
20.2.1
Fire enclosure required:
1) circuits and components where the available
power exceeds 15 W,
2) inductors and windings conductively connected to
the mains, and
3) high-voltage products.
1) circuits and components where the available
power exceeds 15 W,
2) inductors and windings conductively connected to
the mains, and
3) high-voltage products.
P
The fire enclosure complies with the flammability
requirements of Table 22 per UL 94 and 746C
requirements of Table 22 per UL 94 and 746C
Wood and metal enclosure
comply
comply
P
Reference to IEC 60707 or clause G.1 of annex G
replaced by UL 94 or UL 746C
replaced by UL 94 or UL 746C
P
Table 22 - Flammability categories for fire enclosures
P
20.2.2
Internal fire enclosures openings and material
requirements
requirements
N/A
Compliance is checked by inspection and
measurement and using the articulated finger probe,
figure 18.
measurement and using the articulated finger probe,
figure 18.
N/A
20.2.3
Outer enclosures have a minimum flammability
rating of HB when an internal fire enclosure is
provided
rating of HB when an internal fire enclosure is
provided
N/A
A
Apparatus intended for outdoor use or for wet locations
N/A
a) provided with a means to be transportable
N/A
b) has a mass less than 35 kg
N/A
Click on the first or last page to see other HKTS 200SUB (serv.man2) service manuals if exist.