Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate ▷ View online
Page 76 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
Canada National Differences acc. to IEC 60065:2001 + A1
19
[Add the following after the second
paragraph] The test of Clause 19.3 is only
required for a) apparatus with a mass of 25 kg
or more;
paragraph] The test of Clause 19.3 is only
required for a) apparatus with a mass of 25 kg
or more;
b) apparatus, excluding loudspeaker systems, with a
height of 1 m or more; or
height of 1 m or more; or
c) Apparatus, including loudspeaker systems, in
combination with a supplied or recommended cart or
stand with a total height of 1 m or more.
combination with a supplied or recommended cart or
stand with a total height of 1 m or more.
[Add the following paragraph]
Apparatus not tested because it is intended to be
fastened in place shall be provided with the following
warning, marked on the apparatus or on a durable
label attached to the mains cord: “WARNING: This
apparatus must be securely attached to the floor/wall
per installation instructions. Tipping, shaking, or
rocking the machine may cause injury/death."
fastened in place shall be provided with the following
warning, marked on the apparatus or on a durable
label attached to the mains cord: “WARNING: This
apparatus must be securely attached to the floor/wall
per installation instructions. Tipping, shaking, or
rocking the machine may cause injury/death."
N/A
20.2.1A
[Add the following clause]
Enclosures of apparatus containing high-voltage or
projection lamps shall have a minimum flammability
rating of category FV 1 according to IEC 60707 at the
minimum thickness used.
projection lamps shall have a minimum flammability
rating of category FV 1 according to IEC 60707 at the
minimum thickness used.
N/A
Annex B
(normative)
(normative)
Apparatus to be connected to the telecommunication
networks
networks
[Replace this annex with the following]
Apparatus intended for direct connection to a
telecommunication network shall comply with
telecommunication network shall comply with
a) Clause 19 of CSA C22.2 No. 1; or
b) CAN/CSA-C22.2 No. 60950.
N/A
Page 77 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
APPENDIX US National Differences acc. to IEC 60065:2001 + Amd 1:2005
P
1.1.1
Delete reference to Annex L: Electronic flash
apparatus for photographic purposes and replace
with reference to UL 122.
apparatus for photographic purposes and replace
with reference to UL 122.
P
Mains connected apparatus intended for field
installation complies with the National Electrical
Code, ANSI, NFPA 70.
installation complies with the National Electrical
Code, ANSI, NFPA 70.
P
1.1.3
Requirements of apparatus intended for outdoor use
comply with applicable clause of Annex A
comply with applicable clause of Annex A
Indoor use only.
N/A
1.1.5
Some equipment covered by these requirements
may also be required to comply with applicable
requirements in other appropriate standards ........ :
may also be required to comply with applicable
requirements in other appropriate standards ........ :
N/A
4.2.1
The rated supply voltage for single phase apparatus
is assumed to be 120V or 120/240V
is assumed to be 120V or 120/240V
Only for the rated input
voltage range:
voltage range:
AC 100-120 V
P
4.2.4
a) Minimum audio output is not less than 0.5 W per
channel unless the maximum audio output is less
than 0.5 W per channel
channel unless the maximum audio output is less
than 0.5 W per channel
P
4.2.4.1
An apparatus with multiple modes of operation,
multiple signal input sources, or both, is operated
according to the manufacturer's instructions to
produce the maximum power input
multiple signal input sources, or both, is operated
according to the manufacturer's instructions to
produce the maximum power input
P
4.2.11
Table 2 - External supply sources are assumed to be
capable of delivering 30 A, unless otherwise
specified (UL 60065 no-load voltage and internal
resistance values)
capable of delivering 30 A, unless otherwise
specified (UL 60065 no-load voltage and internal
resistance values)
N/A
4.3.4
As an alternative, PTC thermistors may also comply
with UL 1434.
with UL 1434.
No PTC thermistors used
N/A
5
As an alternative, a reagent grade hexane with a
minimum 85% as n-hexane may be used.
minimum 85% as n-hexane may be used.
N/A
Test for conductive labels secured in place by
adhesive
adhesive
N/A
5.1
Component power supplies and adapters complying
with UL 1310, UL 1950, or UL 60950 are considered
to fulfill items "a" through "i" of this clause.
with UL 1310, UL 1950, or UL 60950 are considered
to fulfill items "a" through "i" of this clause.
N/A
5.1f
Rated mains frequency marking on apparatus
50/60 Hz
P
5.1g
Rated current or power marking on apparatus
supplied by supply apparatus for general use
supplied by supply apparatus for general use
(see copy marking plate)
P
Page 78 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
5.1j
Date of Manufacture marking
The date of manufacture
marked on package as a
data code
marked on package as a
data code
P
5.1k
Factory origin identification marking
N/A
5.1l
Combination of two graphical symbols and
supplementary marking and/or single graphical
symbol marking
supplementary marking and/or single graphical
symbol marking
P
5.1m
Equipment rack marking for audio/video systems
N/A
5.1n
Class I apparatus having touch current levels greater
than 0.75 MIU and equal to or less than 3.5 MIU
must be marked with a high touch current marking.
than 0.75 MIU and equal to or less than 3.5 MIU
must be marked with a high touch current marking.
Class II equipment.
N/A
5.1o
Marking on apparatus having grille/ventilation areas
of the top surface that are permitted to have higher
temperature rises according to Note b of Table 3
of the top surface that are permitted to have higher
temperature rises according to Note b of Table 3
N/A
5.2c
Output terminals are marked with voltage, frequency
and current or power; output terminals installed or
interconnected in the field must be marked with the
class of wiring
and current or power; output terminals installed or
interconnected in the field must be marked with the
class of wiring
N/A
5.2d
Speaker terminals are marked "Class 1 Wiring",
"Class 2 Wiring" or "Class 3 Wiring".
"Class 2 Wiring" or "Class 3 Wiring".
N/A
5.2d
Operation manual explains risks and proper
connecting and insulating techniques when
connecting a speaker
connecting and insulating techniques when
connecting a speaker
N/A
5.3
An explanation and illustration of safety related
graphical symbols used on the apparatus are
included in the user instructions preceding any
operating instructions
graphical symbols used on the apparatus are
included in the user instructions preceding any
operating instructions
Relevant information
included in the user manual
included in the user manual
P
5.4
Important safety instructions are packed with each
apparatus
apparatus
P
5.4.1
Outdoor use marking for apparatus having no
protection against exposure to water
protection against exposure to water
Indoor use only
N/A
5.4.1e
Deleted
N/A
5.4.1h
Reference to IEC 61695 is replaced by UL 61965
N/A
5.4.3
When user operation and installation instructions
contains instructions for use by skilled persons, the
instructions are separate in format and preceded by
a precautionary warning statement
contains instructions for use by skilled persons, the
instructions are separate in format and preceded by
a precautionary warning statement
N/A
Page 79 of 89
Report No.: 17029429 001
National Deviations
Clause
Requirement
– Test
Result - Remark
Verdict
US National Differences acc. to IEC 60065:2001 + Amd 1:2005
6.1
Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by measuring
the radiation produced by the apparatus employing a
production chassis
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by measuring
the radiation produced by the apparatus employing a
production chassis
No laser radiation
N/A
6.2
References to IEC 60825-1 are deleted
N/A
Apparatus is classified and labeled according to the
Code of Federal Regulations, Title 21, Chapter 1,
Subchapter J, Sections 1010.2, 1010.3, 1040.10 and
1040.11.
Code of Federal Regulations, Title 21, Chapter 1,
Subchapter J, Sections 1010.2, 1010.3, 1040.10 and
1040.11.
N/A
6.2.2
Deleted
N/A
7
Table 3: Delete reference to conditions h and i under
Table item e for lithium batteries
Table item e for lithium batteries
N/A
Table 3: Temperature limits for various classes of
insulation systems according to UL 60065
insulation systems according to UL 60065
P
Table 3, Note a: Materials rated in accordance with
UL 746B may be used within their rated temperature
UL 746B may be used within their rated temperature
P
Table 3, Note b: For grille/ventilation areas in the top
surface directly above internal heatsinks, a
temperature rise up to 65 K is allowed
surface directly above internal heatsinks, a
temperature rise up to 65 K is allowed
N/A
7.2
Applies to thermoplastic materials only. A material
temperature rating can be accepted in lieu of the
softening temperature.
temperature rating can be accepted in lieu of the
softening temperature.
P
The softening test need not be performed on
materials used in UL Listed or Recognized
components
materials used in UL Listed or Recognized
components
P
8.1
Metal parts are corrosion resistant
N/A
8.9.1
Sleeving, tape, tubing, and wire insulation comply
with UL 224, UL 510, or UL 1441
with UL 224, UL 510, or UL 1441
P
8.10
Component power supplies and their internal
insulation complying with UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
clause
insulation complying with UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
clause
N/A
8.17
As an option, winding wire insulation complies with
the requirements in UL Subject 2353
the requirements in UL Subject 2353
N/A
8.19.1
An all-pole switch or circuit breaker is not required to
have contact separation of 3 mm
have contact separation of 3 mm
N/A
8.23
Printed wiring boards involved with the risk of electric
shock comply with the requirements in UL 796.
shock comply with the requirements in UL 796.
N/A