Harman Kardon HKTS 200SUB (serv.man2) EMC - CB Certificate ▷ View online

 
 
 
 
Page 8 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
General requirements 
 
Safety class of the apparatus  ................................:  Class II 
 
4 
General test conditions 
4.1.4 
Ventilation instructions require the use of the test 
box  
Not used 
N/A 
 
5 
Marking and instructions 
 
Comprehensible and easily discernible 
The rating label is easily 
discernible 
 
Permanent durability against water and petroleum 
spirit  
Compliance was checked by 
rubbing the marking by hand 
for 15 s with cloth soaked with 
water and cloth soaked with 
petroleum spirit, it was not 
possible to remove marking 
plate and no curling observed 
after the test 
5.1 
a) Identification, maker  ........................................ :  Identification mark: 
 
 
b) Model number or type reference ....................... :  HKTS200SUB 
 
c) Class II symbol if applicable  ............................. : 
Marked on rear panel of 
subwoofer 
 
d) Nature of supply ............................................... :  ~ 
 
e) Rated supply voltage  ....................................... :  100-120V~ or 220-240V~, 
indication on PCB for the set 
voltage by CN2  
 
f) Mains frequency if safety dependant  ................. :  50/60Hz 
 
g) Rated current or power consumption for 
apparatus supplied by supply apparatus for general 
use  ..................................................................... : 
 
N/A 
 
Measured current or power consumption  ............. :   
N/A 
 
Deviation % (max 10%)  ....................................... :   
N/A 
 
h) Rated current or power consumption for apparat-
us intended for connection to an a.c. mains supply  : 
200W 
 
Measured current or power consumption  ............. :  (see appended table 7.1) 
 
Measured current or power consumption for 
Television set  ...................................................... : 
 
N/A 
 
Deviation % (max 10%)  ....................................... :  (see appended table 7.1) 
5.2 
a) Earth terminal  
Class II apparatus 
N/A 
 
b) Hazardous live terminals  
 
N/A 
 
 
 
 
Page 9 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
c) Markings on supply output terminals 
 
N/A 
5.3 
a) Use of triangle with exclamation mark  
Marked on the circuit diagram 
 
b) marking on loudspeaker grille, IEC 60417-5036 
 
N/A 
5.4 
Instructions for use 
English & French  
(Version in other language will 
be provided when submitted 
for national approval) 
5.4.1 
 
a) Mains powered equipment not exposed to 
dripping or splashing. Warning concerning objects 
filled with liquid, etc.  
Indoor use only and warning 
mentioned in user manual  
 
b) Hazardous live terminals, instructions for wiring   
No such terminals. 
N/A 
 
c) Instructions for replacing lithium battery  
 
N/A 
 
d) Class I earth connection warning  
Class II apparatus 
N/A 
 
e) Instructions for multimedia system connection  
 
 
f) Special stability warning for attachment of the 
apparatus to the floor/wall  
 
N/A 
 
g) Warning: battery exposure to heat  
 
N/A 
 
h) Warning: protective film on CRT face  
 
N/A 
5.4.2 
a-b) Disconnect device: plug/coupler or all-pole 
mains switch location, accessibility and markings  
Mains plug on non-detachable 
power cord used as disconnect 
device and user manual 
provided regarding being 
readily operable 
 
c) Instructions for permanently connected equipment   No such equipment 
N/A 
 
Marking, signal lamps or similar for completely 
disconnection from the mains  
 
N/A 
 
Hazardous radiation 
N/A 
6.1 
Ionizing radiation < 36 pA/kg (0,5 mR/h)  
No such device 
N/A 
 
Ionizing radiation under fault condition  
 
N/A 
6.2 
Laser radiation, emission limits to IEC 60825-1:2007
 ............................................................................: 
No laser, only optical port used 
for optical input. 
N/A 
 
Emission limits under fault conditions  ....................:   
N/A 
 
7 
Heating under normal operating conditions 
7.1 
Temperature rises not exceeding specified values; 
fuse links and other protective devices defeated  
(see appended table 7.1) 
7.1.1 
Temperature rise of accessible parts  
(see appended table 7.1) 
7.1.2 
Temperature rise of parts providing electrical 
insulation  
(see appended table 7.1) 
 
 
 
 
Page 10 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
7.1.3 
Temperature rise of parts acting as a support or as a 
mechanical barrier  
(see appended table 7.1) 
7.1.4 
Temperature rise of windings  
(see appended table 7.1) 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
N/A 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0,2 A at least 150
 o
C  
Bobbin of switching isolating 
transformers TR1, TR2 and 
TR3 made from phenolic 
material and considered to be 
sufficient in regard to the 
temperature characteristic (150 
C). see appended table 7.2  
only for bobbin of Line Filter 
LF2. 
 
Constructional requirements with regard to the protection against electric 
shock 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
No such material 
N/A 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
It is not possible for user to 
access fuse-link. No user or 
service accessible voltage 
setting device. No such  
indicators or drawers 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
168h, 40°C, RH 93% (for wood 
material by client request) 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the 
removal of a cover which can be removed by hand  
No such cover which can be 
removed by hand 
N/A 
8.5 
Class I equipment  
Class II apparatus 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 
N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 
N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 
N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
Class II equipment 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
Reinforced or double insulation 
used between hazardous live 
parts and accessible parts 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
Switching isolating transformer 
complied with clause 14.3 
 
 
 
 
Page 11 of 89 
 
 
 
Report No.: 17029429 001 
 
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
No such components 
N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.1 a)  
No such capacitors  
N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
No such capacitors  
N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
Approved Y1 capacitor bridged 
between primary and 
secondary circuits/metal 
enclosure 
 (see appended table 14) 
8.7 
This clause is void  
 
-- 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) : 
Thickness of transformer 
bobbin, see appended table 14 
 
Reinforced insulation > 0,4 mm (mm) ...................: 
See appended table 14 for 
below information: 
- thickness of enclosure  
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
  
 
Basic or supplementary insulation, at least two 
layers, each meeting 10.3  
 
N/A 
 
Basic or supplementary insulation, three layers any 
two of which meet 10.3  
 
N/A 
 
Reinforced insulation, two layers each of which meet 
10.3  
 
N/A 
 
Reinforced insulation, three layers any two which 
meet 10.3  
(see appended table 10.3 and 
clause 8.17) 
8.9 
Adequate insulation between internal hazardous live 
conductors and accessible parts  
Double/reinforced insulation 
between primary live parts and 
accessible parts 
 
Adequate insulation between internal hazardous live 
parts and conductors connected to accessible parts  
Basic insulated secondary 
wires cannot touch hazardous 
live parts, wire near to primary 
side of power board already 
fixed by ties. 
8.10 
Double insulation between conductors connected to 
the mains and accessible parts. 
 
 
Double insulation between internal hazardous live 
parts and conductors connected to accessible parts. 
 
8.11 
Detaching of wires  
 